RADIUS
Product
Description
PDR221
iom_pdr221_04_r02.doc
Rev 02
Page 48 (60)
12.4 Configuration Menus
After pressing ‘C’, the main menu is displayed.
To enter a sub menu, enter the number, or letter, to the left of the menu name.
12.5 Function
Operation mode selection; Master, Slave, Slave Via Repeater, Slave With Delay for Repeater or
Peer To Peer. See chapter 7.8 and 7.9.
12.6 Network
12.6.1 System ID
The System ID is used to identify the communication within one radio system. If a radio receives a
radio message with an “unknown” System Id, it will neglect the message. Therefore, all units in the
same radio system shall have the same System Id. The System ID range is 01 to 99. (Entering 00
will clear the System ID). See also chapter 12.6.3, Repeat Alternative Systems.
12.6.2 Radio ID
The Radio ID is used to identify each radio in the network. All radios in the network shall have
different Radio ID’s. The Radio ID range is 01 is 99.Thus, one PDR radio network can contain 99
radio units. (Entering 00 will clear the Radio ID).
Packet Data Radio - PDR221
Copyright RADIUS Sweden AB
Software: PDR221S v1.0 Build Jul 14 2004
AN:124356-1 SwNo:51 HwNo:18
1. Function : Master
2. Network
3. Serial
4. Radio
5. Advanced
6. List Configuration
E. Exit Configuration Mode
Network
1. System ID : 01
2. Radio ID : 01
3. Repeat Alternative Systems