Operating instructions Radius belalatus® ten fan-

shaped awning 

for end users

 

 

1.3

 

Using the belalatus® ten 

When installing and operating the fan awning, the intended use must be observed: 

  The fan-shaped awning (fan) is to be used exclusively as weather-resistant sun 

protection. The wind resistance of the open fan is limited and the information on this 
assumes that it is installed according to the instructions. 

  The wind resistance of the opened fan is limited. The fan must be closed when the wind 

picks up or gusts of wind are approaching. Unattended fan awnings must not remain 
open. Surprising strong winds could cause serious damage. 

  Before opening and closing the fan, check that there are no obstacles in the travel range. 

  The fan awning may not be modified or hung with foreign material. 

  Only use the sunblind in an undamaged condition and pay attention to possible faults. 

Arrange for its professional repair before further use! 

  Only use original Radius accessories and spare parts to ensure safety, unadulterated 

comfort and flawless function. 

  Where appropriate, a self-standing, stable climbing aid shall be used to attach or remove 

a protective cover. Make sure that it cannot tip over or slip away. 

  The individual fan motors have overload protection. If a motor is moved for 6 minutes, it 

is blocked for 18 minutes. Only after this time is further operation possible again. 
However, an exception is a "priority signal" from a connected wind monitor or KNX 
system. 

  Conversions or changes to the fan, control unit, remote control, motor and all connecting 

cables are prohibited! 

  The controller may only be operated with the mains voltage specified on the type plate! 

  It is essential to use the supplied power cord. Operating the control unit with a damaged 

power cable is prohibited! 

  Electrical cables must not be exposed to any danger of crushing, bending or tensile 

stress. 

  It shall be possible to switch the control system on and off by means of an electric switch 

which can be operated quickly and easily even in an emergency situation. 

 

If the control unit is exposed to sunlight, it must be protected from direct sunlight 
with a well ventilated protective hood. The control unit has an IP 65 water 
protection rating

.

 

 

 

 

 

 

 

 

 

Содержание Belalatus ten

Страница 1: ...ng angles Table of contents 1 Safety requirements 2 1 1 Explanations of symbols and notes 2 1 2 General safety instructions 2 1 3 Using the fan 3 1 4 Scope of delivery 4 1 5 Customer accomplishment 4 1 6 Options 4 2 Operation 5 3 Operation with a smartphone app 5 3 1 Pairing with the Radius smartphone app 5 3 2 Opening and closing the fan 6 3 3 Favorite 6 3 4 Additional information 7 4 Operation w...

Страница 2: ...l liability or warranty The fan must be closed when the wind picks up or gusts of wind are approaching Unattended fans must not be left open unless the purchased system has a wind monitor that works with the fan Surprising strong winds could cause serious damage As the connection between the control unit radio remote control or smartphone and the control unit is established via Bluetooth the possi...

Страница 3: ...us accessories and spare parts to ensure safety unadulterated comfort and flawless function Where appropriate a self standing stable climbing aid shall be used to attach or remove a protective cover Make sure that it cannot tip over or slip away The individual fan motors have overload protection If a motor is moved for 6 minutes it is blocked for 18 minutes Only after this time is further operatio...

Страница 4: ...aped awning 2 Control module control box remote control and power cable 3 Antenna 4 Sun and wind sensor optional 1 5 Customer accomplishment mounting device console varies depending on the place of installation on site installation material sleeves screws bases etc electrical supply lines mounting the fan 1 6 Options protective cover wind monitor with receiver for radio control well ventilated pro...

Страница 5: ...radorm handheld transmitters can be taught in 3 Operation with a smartphone app 3 1 Pairing with the Radius smartphone app The Radius app can be downloaded free of charge from the Apple Store under Radius Control When using the app for the first time or resetting it you can proceed step by step using the menu navigation Click CONTINUE This remote control is included in the scope of delivery Press ...

Страница 6: ... positions were set so that the fan remains limited in its movements Using the memory buttons M1 M4 positions can be approached automatically press button for approx 1 second If you want to stop this automatic movement simply press the Memory button again Further options can be selected using the function keys in the lower menu bar a b c Midday position and parking position are permanently stored ...

Страница 7: ...rrent free switching unplugging Only the newly programmed sun protection may be connected to the mains Otherwise you risk a malfunction of the fans that are already in operation 4 Operation with a radio handled transmitter The keys M1 M3 are memory keys and any position can be defined and then moved to automatically as with the iOS app Move to the desired position and press the Memory button 3 tim...

Страница 8: ...nitoring system If the solar radiation is not sufficient in such a situation then the stored position of the fan is closed for the sun and wind monitor system This means that the system would not close automatically when the wind comes up because the position for the system is already closed It must therefore be ensured that when the fan is connected to a sun and wind sensor system the Somfy Telis...

Страница 9: ...it to the mains Error Pulse direction wrong Disconnect the system from the mains for approx 15 seconds and reconnect it to the mains If it still does not work the Radius installer should be notified for rectification If the current fails while the control inputs are active it cannot be excluded that an initialization must be done For this purpose the following procedure can be carried out via the ...

Отзывы: