1)

 

Double Action  (AD Models) 

 
First, the dust cover plugs from the air intake ports must be removed.  After the plugs are removed, the air 
supply lines must be connected to the two inlet ports that are located on the side of the actuator body:                                               
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
Standard units operate in the following manner: 
 
 

Port A: Counterclockwise rotation / opening the actuator. 

 

Port B: Clockwise rotation / closing the actuator. 

 
1)

 

Single action (AS Models) 

 
As in the double action actuators, the dust cover plugs must be removed first; then, the air supply line must 
be connected to Port A. 
 
-

 

With an electrically-operated valve. 

 

The air supply line(s) must simply be connected to the valve’s pressure inlet ports. 
 
 

MAINTENANCE 
 

CAUTION: DISCONNECT ALL AIR SUPPLY LINES AND ELECTRICAL 
POWER BEFORE STARTING ANY MAINTENANCE WORK. 

 
All the actuators are supplied sufficiently lubricated for their normal life.  The lubricants are silicone free.  
In the event that the actuators should require lubrication, the use of  OPTIMOL OLIT2 grease is 
recommended.  Grease for high and low temperatures are also available, but please consult RADIUS before 
using it. 
 
In the case of especially hard working conditions, a periodic check of gaskets, bearings, grease and springs 
is recommended.  The periodical replacement of the above mentioned parts it is also recommended.  For 
this purpose, RADIUS has complete replacement parts kits available.  These kits can be easily purchased 
by contacting RADIUS or any of its distributors.  (See replacement parts paragraph) 
 

PORT A

PORT B

Содержание A Series

Страница 1: ... system This system allows a complete regulation of the opening and closing of the aperture without having to remove the covers The standard units produce a torque between 132 and 52 660 lb in at 80 psi that together with the shaft s output range and its modular design allows the attachment of a wide variety of control accessories ATTACHMENT OF THE ACTUATOR The RADIUS actuators can be installed di...

Страница 2: ...ll the bolts 6 At this point check that the actuator and the valve are in the desired position 7 In the event that it is not correctly positioned remove the actuator and repeat all the steps WARNING NEVER REMOVE A PRESSURIZED ACTUATOR FEATURES AND OPERATING PRINCIPLES 1 Basic Actuator The RADIUS actuator shaft rotates a full 90 some models can be ordered with a 180 rotation angle The opening rotat...

Страница 3: ...f the actuator shaft turning it in the desired direction RADIUS also offers a varied range of declutchable gear operators for this operation For more information consult RADIUS WARNING MAKE SURE THAT THE ACTUATOR IS NOT OPERATING AUTOMATICALLY WHEN A MANUAL OPERATION IS BEING PERFORMED NOTE A PROPER RELEASE OF AIR IS REQUIRED FOR MANUAL OPERATION THIS REQUIRES THE DISCONNECTION OF THE AIR LINES OR...

Страница 4: ...0 0 116 1 1 2 1 2 2 4 AD AS 060 161 2 194 7 2 4 2 4 3 6 AD AS 100 240 1 269 1 3 5 3 5 5 8 AD AS 200 383 9 491 3 5 8 5 8 8 11 AD AS 250 467 5 533 6 6 8 6 8 10 14 AD AS 370 863 1 1067 2 7 9 11 14 17 20 AIR SUPPLY AND ELECTRICAL INSTALLATION A AIR SUPPLY RADIUS actuators are correctly lubricated at the factory All lubricants are silicone free The use of dry clean air or gas is recommended for optimal...

Страница 5: ...e s must simply be connected to the valve s pressure inlet ports MAINTENANCE CAUTION DISCONNECT ALL AIR SUPPLY LINES AND ELECTRICAL POWER BEFORE STARTING ANY MAINTENANCE WORK All the actuators are supplied sufficiently lubricated for their normal life The lubricants are silicone free In the event that the actuators should require lubrication the use of OPTIMOL OLIT2 grease is recommended Grease fo...

Страница 6: ...it for each model These spring must be replaced in complete sets In each kit of springs both springs and pre tensors are supplied Model Quantity AS 003 6 AS 005 12 AS 008 AS 012 AS 020 16 AS 030 AS 040 20 AS 060 AS 100 20 AS 200 AS 370 20 AS 140 24 AS 250 AS 500 40 42 STORAGE When an actuator is not put in service immediately or is used intermittently it is recommended that the actuator is operate...

Страница 7: ...amage the actuator s body If it does not have sharp edges remove the piston from its bore To reassemble the actuator it is necessary to perform the following steps 1 When replacing the O Rings care must be taken to insure that all the parts are completely clean and that all the seal seats are lightly greased 2 The gears the spring bores and the springs themselves must be abundantly greased before ...

Страница 8: ...y to replace the springs of a single action actuator make sure that the springs are installed in the same position as before When less springs than usual are used they must be installed as shown below AS005A AS003A 6 3 Spring Set 8 4 Spring Set 10 5 Spring Set AS008A AS012A AS020A 8 Spring Set 12 Spring Set 10 Spring Set 14 Spring Set ...

Страница 9: ...e seats that are on the piston Install the cover over the springs aligning them with their appropriate seats in the cover Install the cover screws in the retention holes that are in the covers If it is desired to convert a double action unit into a single action unit it is only necessary to install the springs Tighten the screws in the threaded bores in the actuator forcing them slowly down into t...

Страница 10: ...g and stop nut assembly 19 20 and 18 so that they come out of the housing in one piece 4 Loosen or tighten the internal stop screw 16 according to whether more or less travel has to be given to the actuator closing It is very important that the two screws are adjusted equally 5 Once the internal stop screw is adjusted connect the air to port A to start the actuator s opening process and screw the ...

Страница 11: ...ed Detach air lines and remove debris Air supply is too low Increase air supply at regulator Pilot valve malfunction Check proper operation of pilot valve replace Seals are worn Rebuild with new seal kit Actuator undersized for application Replace with larger actuator Actuator seized during winter outside application water in compressed air Thaw actuator remove water Install air dryer Actuator is ...