![RadiSys EPC-23 Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/radisys/epc-23/epc-23_hardware-reference-manual_780523026.webp)
EPC-23 Hardware Reference
Resetting the EPC
There are a number of ways to reset (reboot) the EPC.
Power-off, Power-on
3
3
This causes the entire system to reset. The system will run the power-on
self-tests and reboot the operating system.
Front-panel Reset button
The Reset button causes the EPC to perform a hardware reset. The system
will run the power-on self-tests and reboot the operating system.
Expansion Interface
Pin A57 on the EXM expansion connector is defined as ~RESETIN.
Asserting this input (low) will reset the processor. This is provided to allow
remote reset to be implemented. This is a full hardware reset. The system
will run the power-on self-tests and reboot the operating system.
Setup Screen
Pressing F10 and then F5 to save changes and reboot causes a full hardware
reset.
CTRL+ALT+DEL
This keyboard sequence is called a "warm boot." The EPC does not
reinitialize all of the processor's hardware. The power-on self-test does not
run. However, the operating system will be reloaded. This type of reset
typically only works under DOS.
Additional abnormal conditions that cause a reset
Low Vcc
No DRAM refresh signal from the micromonitor