![RadiSys ATCA-4616 Скачать руководство пользователя страница 103](http://html.mh-extra.com/html/radisys/atca-4616/atca-4616_reference_780512103.webp)
B
IPMI Commands and Managed Sensors
103
68
CPU0 Core DTS
Temperature
Threshold
25
LNR = N/A
LC = N/A
LNC = N/A
UNC = -20
UC = -13
UNR = -1
69
CPU1 Core DTS
Temperature
Threshold
25
LNR = N/A
LC = N/A
LNC = N/A
UNC = -20
UC = -13
UNR = -1
Event-only Sensors
90
Memory Memory
Sensor-
specific
N/A
Offset
Description
00h
=
Correctable ECC / other correctable memory error
01h
=
Uncorrectable ECC / other correctable memory error
04h
=
Memory Device Disabled
05h
=
Correctable ECC / other correctable memory error
logging limit reached
07h
=
Configuration error
Event Data 2 (for both event offsets 4h, 7h):
OEM - DIMM location
[7:6] - Reserved
[5:3] - Channel
00 - Channel 'A' on silkscreen
01 - Channel 'B' on silkscreen
10 - Channel 'C' on silkscreen
11 - Unspecified
[2:0] - DIMM
00 ~ 10 - According to the label on silkscreen
11 - Unspecified
Event Data 3 (for both event offsets 0h, 1h):
[7:6] - Reserved
[5:4] - Channel number
[3:0] - DIMM number
Event Data 3 (for both event offsets 4h, 7h): OEM data
91
Critical Interrupt
Critical Interrupt Sensor-
specific
N/A
04h - PCI PERR
05h - PCI SERR
Event Data 2 (for both event offsets 4h, 5h):
PCI bus number for failed device
Event Data 3 (for both event offsets 4h, 5h):
[7:3] - PCI device number for failed device
[2:0] - PCI function number for failed device
Table 38. ATCA-46xx IPMI Managed Sensors (continued)
Sensor
#
Name
Type
Reading
Type
Normal
Reading
Notes