background image

 
 

FP103230-1 REV.K 

 

Page 

10

 of 

12

 

 

A

zimuth Adjustment: 

 

1. 

Loosen the 4 Azimuth Lock Bolts so mounting plate can move. 

Caution: Failure to loosen bolts before adjusting will result in damage 

to mount 

2. 

Adjust mounting plate using eyebolt adjustment nuts to drive antenna to 
required location. Monitor RCL (Receive Carrier Level) and adjust per 
radio manufacturer’s instructions. Verify antenna is adjusted on main 
beam by passing through main beam and out to left and right 1

st

 

sidelobe. Return antenna to main beam RCL. 

3. 

Securely tighten the 4 Azimuth Lock Bolts. 

4. 

Securely tighten eyebolt adjustment nuts.   

5. 

Re-check Elevation and adjust if necessary 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 

Elevation 
Adjustment Nut 

Azimuth 
Lock Bolts 

Azimuth 
Lock Bolts 

Eyebolt Azimuth 
Adjustment Nuts 

Содержание HGSN Antennas

Страница 1: ...845 USA Tel 978 459 8800 fax 978 459 3310 8814 Email sales radiowaves com www radiowaves com FIELD PROCEDURE FOR POLE MOUNT Used With HPCPE HPLP1 HPLPD1 SP1 HPLP2 HP2 HPD2 SP2 SPD2 HGSN Antennas HPCPE HPLP1 HPLPD1 SP1 HP2 HPD2 SP2 SPD2 ...

Страница 2: ...essories are shipped separately and include separate installation guides Check the packing slip Tools Required 1 9 16 Open box wrench or deep socket wrench 2 Torque Wrench with appropriate sockets 3 2 Phillips screwdriver FOR SP2 SPD2 UNITS ONLY NOTE The pictures provided in this document are for illustrative purposes only and may not be identical to your antenna system ...

Страница 3: ...EV K Page 3 of 12 Mounting Kit Component identification Pole Mount Components and hardware Antenna Mounting Plate with associated hardware Antenna Hardware Kit attaches antenna to mounting plate Azimuth Adjust Bolt ...

Страница 4: ...rdware supplied with plate Notes Right hand offset is shown for Left hand offset rotate mounting plate 180º See step 3 for photo Adjustments to the antenna may be necessary for Left hand offset mounting refer to additional instructions for your antenna model Top of mounting plate indicated by Elevation Adjustment Nut Confirm that the Mount is centered as shown Tighten bolts Securely Align pin in p...

Страница 5: ...shown Adjustment Nut Align pin in plate with hole on mount Hardware sequence Flat washer between mount and rod bushing fits inside rod end flat washer lock washer bolt Confirm that the Mount is centered as shown Use the flat washer lock washer and nut for each lock bolt 4X Tighten securely ...

Страница 6: ...FP103230 1 REV K Page 6 of 12 4 Completed assembly views Top Adjustment nut on top Top Adjustment nut on bottom Rod on bottom Right hand offset Left hand offset ...

Страница 7: ... as the antenna and packed with the pole mount You will need a 2 Phillips screwdriver to install the plate 2 Prior to attaching the mount assembly to the pole install diamond mount adapter plate on antenna as shown Tighten securely Diamond Mount adapter plate Mount Adapter plate Attach using 4 1 4 20 screws lock washers and flat washers provided with antenna Tighten securely Ensure slot faces away...

Страница 8: ...at face of mounting plate is parallel to desired beam path 2 Align center hole of antenna with pivot pin and elevation slot with elevation pin Push antenna towards mount and engage pins Hold in place IMPORTANT Do not loosen the 4 bolts securing the upper and lower mounting brackets Pole Mount Antenna Pivot Pin Elevation Pin Elevation Slot Center Hole ...

Страница 9: ...FP103230 1 REV K Page 9 of 12 3 While supporting antenna install 2 3 8 16 bolts with washers as shown through mounting plate and into antenna Tighten securely Antenna is now mounted ...

Страница 10: ...required location Monitor RCL Receive Carrier Level and adjust per radio manufacturer s instructions Verify antenna is adjusted on main beam by passing through main beam and out to left and right 1st sidelobe Return antenna to main beam RCL 3 Securely tighten the 4 Azimuth Lock Bolts 4 Securely tighten eyebolt adjustment nuts 5 Re check Elevation and adjust if necessary Elevation Adjustment Nut Az...

Страница 11: ...sted on main beam by passing through main beam and out to upper and lower 1st side lobe Return antenna to main beam RCL Note Adjustment is smoother when adjusting beam upward Drive antenna down past desired location and adjust while driving antenna up 3 Tighten mounting bolts securely after elevation is set 4 Re check Azimuth and adjust if necessary Final Inspection When the antenna orientation is...

Страница 12: ...ine Should your antenna or related hardware come in contact with power lines you could be killed Be sure your installation is out of falling distance of any overhead wires including the lead to any building or structure NEVER OPERATE OR LOCATE THIS OR ANY EQUIPMENT NEAR POWER LINES Electrocution Hazard Portable or Mobile Installation If you are installing a Radio Waves Inc component or part on a p...