http://SERVER-ADDRESS/DATAIN

http://SERVER-ADDRESS/DATAIN

DATAIN

DATAIN

 is the server 

program name that processes checkin requests, which can be either 

datain.php, datain.asp

datain.php, datain.asp

 or 

datain.js

datain.js

.

 

gwid

gwid

: MAC address of the device

 

model

model

: Model number of the device

 

interval

interval

: Data transfer interval

 

ipaddr

ipaddr

: IP address of the device

 

utc

utc

: Transfer time (information provided by www.ntppool.org)

 

__device

__device

: The device's MAC address, preceded by 0000

 

nodeid

nodeid

: The device's MAC address, preceded by 0000

 

lqi

lqi

: Indicates the strength of wireless signal, but for RN17xWC 

Series, this parameter is fixed as 255.

 

child

child

: Indicates the number of child nodes, but for RN17xWC 

Series, this parameter is fixed as zero.

 

nodetype

nodetype

: Indicates the type of node, but for RN17xWC Series, 

this parameter is fixed as 2.

 

batt

batt

: Indicates the battery status of the device, but for 

RN17xWC Series, this parameter is fixed as 255.

 

sd1

sd1

: Measurement of Channel 1

 

sd2

sd2

: Measurement of Channel 2

Measurements can include a negative sign and up to 2 decimal 

places.

The server should reply to a datain request with a process outcome 

in the following XML format:

<xml>

<xml>
<root>

<root>
<ack>ok</ack>

<ack>ok</ack>
</room>

</room>
</xml>

</xml>

Abnormal replies include error messages.

<ack> MESSAGE </ack>

<ack> MESSAGE </ack>

HT

TP R
adionode 

Pr

ot

oc

ol V1

Содержание RN171WC

Страница 1: ...User Manual Ethernet Sensor Data Transmitter RN171WC Keep this document nearby so that it may be referred to when needed 2021 Rev 1 03 ...

Страница 2: ...nual 04 Intellectual Property Rights 04 Notational Conventions 04 Introduction 05 Key Features 05 Exterior 06 Compatible UA Sensors 06 Accessories 07 Specifications 07 Configuration 08 Network 09 System 10 Alarm 11 Customer Server 12 Modbus 13 Installation 14 Installation 14 Connecting Network Cable 14 Connecting UA Sensor 15 Display 16 Radionode 365 17 Adding Devices from Your Smartphone 18 Addin...

Страница 3: ...ionode365 Tapaculo Lite 24 Installing Software 24 Starting Tapaculo Lite 24 Customer Service Information 27 Manufacturer Contact Information 27 Warranty 27 Limit of Liability 27 Certifications 28 Telnet Commands 29 HTTP Radionode Protocol V1 30 Data in 30 Backup in 32 Timestamp 33 HTTP Radionode Protocol V2 34 Check in 34 Data in 36 Modbus Registration 37 Order List 38 UA Sensor 38 Accessories 39 ...

Страница 4: ...s only and may differ from your system depending on installation conditions Software screenshots can be changed after software updates Intellectual Property Rights 2021 DEKIST Co Ltd All contents and figures herein are property of DEKIST Co Ltd Reproduction or redistribution of all or part of this document in any way is not permitted without prior consent from DEKIST Notational Conventions Failure...

Страница 5: ...Radionode365 server or Tapaculo Lite program 3BEJPOPEF 5BQBDVMPm JUF Key Features Key features of RN171WC include Compatibility with a wide variety of UA sensors Transmission of measurements over the Internet to Radionode365 or customer servers See Radionode365 on page 17 Transmission of measurements over the local network to the computer where Tapaculo Lite is installed See Tapaculo Lite on page ...

Страница 6: ... K Temperature Type K Thermocouple UA11 T Temperature Type T Thermocouple UA13 Temperature PT100 UA20A 4 20 mA UA20B 0 20 mA UA20C 0 1 V UA50 Total Volatile Organic Compounds tVOC UA52 O2 25 F Oxygen O atmospheric pressure UA52 CO2 20 Carbon dioxide CO UA53 CO 1000 Carbon monoxide CO UA53 NO2 50 Nitrogen dioxide NO UA53 SO2 50 Sulfur Dioxide SO UA54 NH3 100 Ammonia NH UA54 H2S 50 Hydrogen sulfide ...

Страница 7: ...sor Stickers We recommend using a PoE Power over Ethernet supported router When connected to a PoE router an adapter is not required as power is supplied through a network cable Specifications 5 0 4 m m 35 1 mm 9 0 m m 7 0 m m 5 1 5 m m 40 5 mm Product name RN171 plus Model name RN171WC Ethernet 100 Mbps Modbus Port 502 Telnet Port TCP 23 UDP 50000 USB 2 0 Power DC 6 V or PoE 48 V IEEE 802 3af 802...

Страница 8: ...Radionode website www radionode365 com Without a power connection connect RN171WC to your computer using a USB cable will appear on the display Run the Radionode terminal If the screen background is blue green the device has been recognized Enter radionode114 radionode114 to call five different device information menus 1 Network Setup 1 Network Setup 2 System Setup 2 System Setup 3 Buzzer Siren Se...

Страница 9: ...dress assigned to RN171WC C Set GATEWAY Address 192 168 xxx xxx C Set GATEWAY Address 192 168 xxx xxx Enter the gateway IP address D Set DNS1 Address 192 168 xxx xxx D Set DNS1 Address 192 168 xxx xxx Enter the IP address of the first DNS server E Set DNS2 Address xxx xxx xxx xxx E Set DNS2 Address xxx xxx xxx xxx Enter the IP address of the second DNS server F Set SUBNET MASK 255 255 255 000 F Se...

Страница 10: ...dionode365 server When a customer or third party server is available select CUSTOMER CUSTOMER to use a GET method HTTP request or CUSTOMER_V2 CUSTOMER_V2 to use a POST method Then go to the 4 HTTP Destination 4 HTTP Destination Setup Setup menu and set the server options accordingly See Customer Server on page 12 C Set HTTP Update Interval 300 Sec C Set HTTP Update Interval 300 Sec Set data transf...

Страница 11: ...er limit of the normal range allowed for Channel 1 D Set Alarm CH2 Min 0 00 D Set Alarm CH2 Min 0 00 Enter the lower limit of the normal range allowed for Channel 2 E Set Alarm CH2 Max 0 00 E Set Alarm CH2 Max 0 00 Enter the upper limit of the normal range allowed for Channel 2 F Set BUZZER Alert Enable SOUND ON F Set BUZZER Alert Enable SOUND ON Determine to use the built in buzzer G Set Remote S...

Страница 12: ... the original address Normal system does not require additional setup D Set HTTP DATAIN File Get test jsp D Set HTTP DATAIN File Get test jsp Enter the URL of the server program for data in request processing Entering 0 disables this request function E Set HTTP TIMESTAMP File Get 0 E Set HTTP TIMESTAMP File Get 0 If you are to use a GET method HTTP request enter the URL of the server program that ...

Страница 13: ... for link with PLC Select 5 MODBUS TCP Setup 5 MODBUS TCP Setup to change Modbus settings A Set MODBUS TCP PORT 502 A Set MODBUS TCP PORT 502 Enter the port number for Modbus communication generally port number 502 B SetByteReverse 0 B SetByteReverse 0 Enable disable reverse byte values check if PLC uses reverse bytes C Set Timeout to Keep a live 60 Sec C Set Timeout to Keep a live 60 Sec Enter co...

Страница 14: ...stration About this Manual Installation Installation Secure the main body to the wall with 2 screws Connecting Network Cable Connect the network cable to the Ethernet port When connected to a PoE Fi router an adapter connection is not required as power is supplied through a network cable When using a standard router connect the adapter to the power jack Installation ...

Страница 15: ...ode Protocol V2 Modbus Registration About this Manual Connecting UA Sensor 1 Insert the UA sensor into the USB port 2 There are two protrusions at the top of the sensor protective cover and two holes at the bottom of the body Place the sensor protective cover over the UA sensor so that the two protrusions fit into the two holes Installation ...

Страница 16: ...on the last six digits of the assigned IP address will appear For example if the IP address is 192 168 0 42 it will appear according to the left image Indicates that no sensor is inserted in the device If the appears to be vibrating it indicates that data transfer to the server has failed This indicates the number of data sets waiting when data transfer fails after appears This indicates that re t...

Страница 17: ... outlines how to add new devices and channels to Radionode365 For more information on Radionode365 see the information provided on the web page below https help radionode365 com article categories https help radionode365 com article categories tp365 manual tp365 manual Key features of Radionode365 include Measurement data displayed in real time View measurement data records via charts Create and e...

Страница 18: ... will find a unique QR code for your account The QR code allows you to easily add devices and channels to your smartphone Scan the QR code with your smartphone Alternatively copy the link address from the QR code image and send it to your smartphone 1 Your smartphone s default web browser will open with your user information Tap Add Device When RN17xWC Series first connects to Radionode365 the fol...

Страница 19: ...otocol V1 HTTP Radionode Protocol V2 Modbus Registration About this Manual 2 Enter the i code on the device display If you do not see an i code on the display tap Search by MAC address and enter your MAC address 3 If the i code or MAC address is accurate the device information will appear as below Tap Next Radionode365 ...

Страница 20: ...nformation Telnet Commands HTTP Radionode Protocol V1 HTTP Radionode Protocol V2 Modbus Registration About this Manual 4 Enter your device name check the box of the channel that will be used then enter the channel name and unit that will be used Tap Next to finish Radionode365 ...

Страница 21: ... found in the same IP band are listed here If you do not see your device in the list you can add it using its i code When RN17xWC Series first connects to Radionode365 its i code is displayed as follows Enter the i code above the device list and click Search Devices can also be searched via MAC address instead of their i code The device will be then be added to the list To add your device click th...

Страница 22: ... Device Setup New Data Channel All added device channels will be listed This list also includes channels not associated with external sensors or other devices Adding a channel essentially means selecting a channel to monitor To add a channel click the Add Channel button in the last column Enter the channel name in the window select enter a unit to use then click Save To view the list of added chan...

Страница 23: ...TTP Radionode Protocol V1 HTTP Radionode Protocol V2 Modbus Registration About this Manual Adding Widgets A widget contains one or several channels You can add a widget to the dashboard by clicking Dashboard then Add widget Enter the widget name in the window select channels then click Save Radionode365 ...

Страница 24: ...e tapaculo lite Installing Software To view sensor measurements on your computer download and install the following software package from the Radionode website at www radionode365 com www radionode365 com Tapaculo Lite program Windows or Mac version USB drivers for Windows for UA products Starting Tapaculo Lite A new project must be created first before combining Tapaculo Lite and the sensor A pro...

Страница 25: ...nual Tapaculo Lite 2 Searched sensors appear in the left panel Select a dashboard and sensor then click Add Device The sensor will be added to the dashboard 3 Click Time Interval and select the measurement interval 4 Click OK Create Project at the bottom of the menu The Dashboard menu will open and display measurements of sensors registered in the project and sensor indicators will blink ...

Страница 26: ...mands HTTP Radionode Protocol V1 HTTP Radionode Protocol V2 Modbus Registration About this Manual Tapaculo Lite 5 Click REC at the lower left corner to start logging data The REC button will change to STOP 6 To exit the program click STOP You cannot exit the program until data logging is stopped ...

Страница 27: ...nder normal operating conditions within one year of the product installation date Limit of Liability Warranty repairs are not provided in the event of Failure caused by unapproved installation methods Failure caused by user negligence Failure caused after alteration disassembly or repair of the product by a person unauthorized by DEKIST Failure caused by corrosion falling submersion or other impro...

Страница 28: ...s and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Changes or modifications not expressly approved by the ...

Страница 29: ...rminal mode Device settings can be changed as you would for a RadioNode terminal ATSRESET ATSRESET Reboots the device ATSMODEL ATSMODEL Shows the device model number ATBSET ATBSET Sounds the built in buzzer once ATBAL ATBAL Selects a channel to link alarms ATBAL OFF ATBAL OFF ATBAL CH1 ATBAL CH1 ATBAL CH2 ATBAL CH2 ATBAL CH1 OR CH2 ATBAL CH1 OR CH2 ATBAL CH1 AND CH2 ATBAL CH1 AND CH2 ATBMIN1 ATBMI...

Страница 30: ...ta from the server at a set time This request is called data in When data transfer fails a request is made to the server to transfer accumulated data at once This request is called backup in Device makes a timestamp request to the server to obtain current time in the event that a backup in transaction requires a server time reset Data in Data in requests are in the following format http SERVER ADD...

Страница 31: ...ded by 0000 nodeid nodeid The device s MAC address preceded by 0000 lqi lqi Indicates the strength of wireless signal but for RN17xWC Series this parameter is fixed as 255 child child Indicates the number of child nodes but for RN17xWC Series this parameter is fixed as zero nodetype nodetype Indicates the type of node but for RN17xWC Series this parameter is fixed as 2 batt batt Indicates the batt...

Страница 32: ...0 23 82 A serial number preceded by P P becomes a parameter name and several values including timestamps are separated by vertical lines and grouped together as parameter values Pxxx timestamp nodeid device battery lqi ch1 ch2 Pxxx timestamp nodeid device battery lqi ch1 ch2 One parameter value consists of the following elements Pxxx Pxxx Data number timestamp timestamp Measurement time nodeid nod...

Страница 33: ...bus Registration About this Manual Timestamp Timestamp requests are in the following format http SERVER ADDRESS TIMESTAMP http SERVER ADDRESS TIMESTAMP gwid 0004a316d728 gwid 0004a316d728 Normal replies to this request include a timestamp root root timestamp 1459249259 timestamp timestamp 1459249259 timestamp root root HTTP Radionode Protocol V1 ...

Страница 34: ...e radionode device requests transmission of device information from the server at the start of operation and every six hours thereafter This request is called check in The device requests transmission of measurement data from the server at the set time This request is called data in Check in Check in requests are in the following format POST HTTP 1 1 POST HTTP 1 1 Host 192 168 10 1 checkin Host 19...

Страница 35: ...ags tags CH info This parameter is separated by vertical lines and indicates the nature of each channel tags TEMP RH NTC_TEMP NULL NULL NULL tags TEMP RH NTC_TEMP NULL NULL NULL In this example there are a total of six channels with Channel 1 indicating temperature Channel 2 indicating RH and Channel 3 indicating the temperature measured by NTC external temperature sensor The remaining channels ar...

Страница 36: ...1505911542 23 19 12 40 121 96 123 P000 1505911542 23 19 12 40 121 96 123 P001 1505910942 23 18 12 52 122 04 123 P001 1505910942 23 18 12 52 122 04 123 mac mac MAC address of the device sig sig Strength of wireless signal bat bat Battery status The value ranges from 0 to 255 The battery must be replaced when the value is 5 or less 1 is displayed when DC power is connected SMODEL SMODEL Model number...

Страница 37: ... point real number simultaneously House number consists of two bytes and a floating point real number is represented by four bytes thus the real value of a channel is divided into two Channel 1 Channel 2 Channel 1 Channel 2 Floating decimal real number Floating decimal real number Integer Integer Address 0 1 2 3 4 5 Bytes 0x3333 0x41DF 0x999A 0x41E9 0x001B 0x001D Reverse bytes 0x3333 0xDF41 0x9A99...

Страница 38: ...ransmitter UA20 B 0 1V Transmitter UA20 C tVOC CO2eq Absolute Humidity UA50 Oxygen Atmospheric pressure Temperature UA52 O2 25 UA52 O2 25 F Carbon dioxide Temperature UA52 CO2 20 Carbon monoxide Temperature UA53 CO 1000 Sulfur dioxide Temperature UA53 SO2 50 Nitrogen dioxide Temperature UA53 NO2 50 Ammonia Temperature UA54 NH3 100 UA54 NH3 1000 Hydrogen sulfide Temperature UA54 H2S 50 Hydrogen chl...

Страница 39: ...col V2 About this Manual Modbus Registration Accessories Temperature Sensor Type Order No Cable Length K Type Thermocouple TC K 50 200 C PR K1 3 3 m PR K1 15 15 m T Type Thermocouple TC T 200 200 C PR T1 3 3 m PR T1 15 15 m PT100 200 200 C PR P1 3 3 m PR P1 15 15 m Sensor Data Transmitter Type Order No Remark LAN RN171WC Support PoE WiFi RN172WC Support WiFi ENT ...

Страница 40: ...Telephone 1566 4359 Fax 82 31 8039 4400 Email master dekist com A1801 13 Heungdeok 1 ro Giheung gu Yongin si Gyeonggi do Korea 16954 ⓒ 2021 DEKIST Co Ltd ...