RADIONODE Sensor Data Transmitter Device 

(via Ethernet) 

 

POE(Power Over Ethernet)-supported 

Temperature/Humidity, Thermocouple(T/K

 

 

Type), PT100, 4-20mA, Gas 

For making phone calls alert/sending SMS

 

 

 

 

 

 

alert 

Supports cloud monitoring(Tapaculo365) 

Supports MODBUS TCP/HTTP data 

 transmission 

2CH LED display on the front 

Sound buzzer inside 

   
 
   
  

 

 

  
Product Overview

 

The RN171 Ethernet data transmission device delivers 

the data from the UA sensor products to a remote 

receiver through the Ethernet. 

The remote receiver refers to the PCs where the 

Tapaculo software is installed, a cloud monitoring 

service (Tapaculo®365), or the web server developed 

by the user. 

The RN171 device is equipped with a display 

on the front to show the data, and with a buzzer 

to sound the alarm when the limit value is 

exceeded. 

The system also provides a cloud monitoring 

service, which is one of the advanced features 

of the system (Tapaculo

®

365). 

Using this service, it is possible to send an 

emergency SMS/telephone alarm or schedule 

to send e-mail reports. 

 

Purpose

 

• Gathering sensor information 

   through the network 

• Establishment of an integrated 

 control system 

• Establishing an industrial alarm 

  system 

             Application

 

            •Food storage (freezer, refrigerated) 

            • Bio laboratory 

            • Building energy use monitoring 

            • Medicine storage 

            • Semiconductor production line 

 

 

©2019 DEKIST Co., Ltd.                www.radionode365.com 

 Rev. 1.9 

Содержание RN171

Страница 1: ...nitoring service Tapaculo 365 or the web server developed by the user The RN171 device is equipped with a display on the front to show the data and with a buzzer to sound the alarm when the limit value is exceeded The system also provides a cloud monitoring service which is one of the advanced features of the system Tapaculo 365 Using this service it is possible to send an emergency SMS telephone ...

Страница 2: ...ed green LED SMS transmission Supported TAPACULO365 COM USB Port For connecting to the PC for setting or connecting with the UA series product Making phone calls Supported TAPACULO365 COM Compatible USB sensors RADIONODE UA series Cloud monitoring S2 TAPACULO365 COM LOGIN Display LED display on the front for displaying Data or IP Addr Data transmission frequency Can be configured every minute mini...

Страница 3: ... gas There is a risk of explosion Caution 1 Avoid excessive environmental exposure and do not use it outside the supported operating environment It may shorten the life span of the product and cause malfunction 2 Do not use it to exceed the power voltage range Otherwise the product may be damaged 3 Do not short circuit the load Otherwise the product may be damaged 4 Do not miswire the power such a...

Страница 4: ... the data gathered by UA 10 or UA11 etc The image above shows an example of a configuration of the monitoring server through the intranet without being connected to the internet It is possible to be assigned an IP automatically or to have a fixed IP manually assigned by the user The Tapaculo Lite software provided as a part of the package is used to detect a device and make 2019 DEKIST Co Ltd www ...

Страница 5: ...other devices located in a remote place Each RN171 device will do with a private IP from the internet router No separate public IP is necessary Tapaculo365 com supports data gathering It provides free accounts with which you can use up to 20 data channels The registration of the device is completed by inputting the MAC address indicated on the side of the RN171 unit See 10 How to use the Tapaculo3...

Страница 6: ...P mode by default you can view the IP address on the LED display when the system is powered up When you establish a connection with Telnet enter the ATSCON command to jump to the console menu screen If there is no input made for five minutes the connection will automatically be disengaged Use the terminal software to access the COM port or use Telnet to input radionode114 Then you can access the c...

Страница 7: ...0 000 000 000 F Set SUBNET MASK 255 255 255 000 G Set VMAC D880393E05ED H Set UDP Broadcasting Port 50000 I Set TELNET Port 23 Q Quit A Set DHCP ON OFF If you are to use a fixed IP set it OFF and if using a router set it ON B If you are using a fixed IP input the IP address manually If the DHCP mode is OFF this menu will not appear C Input the gateway IP address manually D Input the address of the...

Страница 8: ...SETUP MENU A Set Alarm Trigger Mode CH1 OR CH2 B Set Alarm CH1 Min 0 00 C Set Alarm CH1 Max 0 00 D Set Alarm CH2 Min 0 00 E Set Alarm CH2 Max 0 00 F Set BUZZER Alert Enable SOUND ON G Set Remote SIREN DEVICE Enable OFF QLIGHT MODEL ST56EL ETNS 2 WS H Set Remote SIREN DEVICE IP 192 168 1 111 I Set Remote SIREN DEVICE Port 2000 Q Quit A Select the channel to use the alarm The available channels are ...

Страница 9: ...ddresses and more For more details see 8 Definition of the HTTP protocol 5 5 MODBUS TCP setting From the PLC or the PCs etc you may use MODBUS TCP to access the RN172 to find out the values of CH1 and CH2 inside 5 MODBUS TCP SETUP MENU HOLDING REGISTER 16BIT FUNCTION CODE 3 OFFSET 0 CH1 FLOATING 32BIT VALUE 16BIT LOW OFFSET 1 CH1 FLOATING 32BIT VALUE 16BIT HIGH OFFSET 2 CH2 FLOATING 32BIT VALUE 16...

Страница 10: ... screen will show the last two digits of the IP address Normally an internet router assigns 192 168 0 1 as the IP address with the last digit varying Expression of the data Expression of the IP address USB sensor Most of the data show the current value The example below shows that the temperature is 19 2 and the humidity is 42 1 When the device is powered up and an IP is assigned automatically the...

Страница 11: ...ta in storage is retransmitted to Tapaculo365 Appears when the device is connected to the PC through the USB without a separate power supply This mode is used to change the settings HoLd 0005 0000 CONF 7 Telnet command While the RN171 device is in operation the user may access the device through Telnet After accessing the 2019 DEKIST Co Ltd www radionode365 com Rev 1 9 ...

Страница 12: ...EL RN171 W B U Z Z E R ATBSET Temporarily activates the internal buzzer of the RN171 OK ATBAL OFF CH1 CH2 OR AND Chooses the alarm condition OFF Do not use the alarm CH1 Alarm activated on Channel 1 CH2 Alarm activated on Channel 2 OR Alarm activated on CH1 or CH2 AND Alarm activated on CH1 and CH2 OK or NOT_OK ATBMIN1 Value Input the Min value of Channel 1 OK or NOT_OK ATBMAX1 Value Input the Max...

Страница 13: ...rently used by RN 171 utc The Unix Timestamp from the default NTP of RN171 If the RN171 device fails to establish a connection with an external NTP server it willprovide incorrect time information This device connects to pool ntp org tapaculo365 com to retrieve the time information __device Uses the MAC address as the unique ID of the node from which the information has been transmitted The NMAC i...

Страница 14: ...cimal digits are ignored and only the integers are delivered Transaction ID Protocol ID and Unit ID are internally ignored Whatever value you input through them they will use 3 as the function code READ HOLDING REGISTER FUNCTION CODE 3 Channel Address Index 16Bit 16Bit Byte Reverse Value CH1 4 Byte Floating 0 0x3333 0x3333 27 9 1 0x41df 0xdf41 CH2 4 Byte Floating 2 0x999a 0x9a99 29 2 3 0x41e9 0xe9...

Страница 15: ...d device The LED on the front blinks in red and green alternately once the power is on Registered device When the power is on you will hear the melody When there is an error with the internet connection There is no reaction when you connect the power Only the green light will remain on 10 2 Registering a new device Access S2 TAPACULO365 COM If you are not yet a member sign up for membership first ...

Страница 16: ...stration process has been completed 10 3 Add a new channel Once a new device is added add a data that transmits the actual data Move to the New Channel menu You will find the data channel that is generated by the newly added device detected If the new channel is not detected wait until the next data update or reboot the device so that the channel can be detected 2019 DEKIST Co Ltd www radionode365...

Страница 17: ...view screen will show the relevant name 10 4 Use the web service After completing the channel registration you may use the various features such as the report dashboard or alarm setting of S2 Tapaculo365 com All the customers who purchased this product may use these features basically free of charge If you require advanced features you may switch to the paid services Ex Dashboard 2019 DEKIST Co Lt...

Страница 18: ...all Tapaculo Lite in your PC Install Tapaculo Lite www radionode365 com Support Software Download Tapaculo Lite on a Windows operated PC and launch the program Click Create Project to create a new project and add the devices 2019 DEKIST Co Ltd www radionode365 com Rev 1 9 ...

Страница 19: ...ted and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to pro vide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may c...

Страница 20: ... year Paid repair service after one year Company DEKIST Co Ltd Phone 070 7529 4359 Fax 031 8039 4400 Email master dekist com 14 Software Download You can download the relevant software at www radionode365 com 2019 DEKIST Co Ltd www radionode365 com Rev 1 9 ...

Отзывы: