background image

K6100 / K6300-CNCII

Central Network Controller

User Guide

17317 Ver 1.2/48569B

Содержание K6300-CNCII

Страница 1: ...K6100 K6300 CNCII Central Network Controller User Guide 17317 Ver 1 2 48569B ...

Страница 2: ...K6100 CNC User Guide 17317 Ver 1 2 48569B Page 2 2001 Radionics ...

Страница 3: ...rity 1 Buffer Full 6 5 3 2 Priority 2 Communications Errors 7 5 3 3 Priority 2 Updates On line 7 5 3 4 Priority 3 Monitoring 8 5 4 Prioritized Messages when PC Offline 8 5 4 1 Priority 1 Alarms 8 5 4 2 Priority 2 Communications Errors 8 5 4 3 Priority 3 Buffer Full 8 5 4 4 Priority 3 PC Offline 8 5 4 5 Priority 4 Updates 8 6 0 Alarms 9 6 1 Unauthorized Access 9 6 2 Anti Tamper 9 6 3 Zone Alarm on ...

Страница 4: ...s Engine A special Readykey application that runs all the time on Readykey for Windows systems in the background This application handles all communications between the other Readykey applications and the Readykey hardware including the CNC and door controllers Modem When used on a Readykey for Windows system this is a device which allows the CNC to communicate with Readykey door controllers over ...

Страница 5: ...are numbered consecutively on each site Each door controller may have a maximum of 4 doors Door 001 on a site will correspond to door 1 on door controller 1 Door 004 to door 4 on door controller 1 Door 005 to door 1 on door controller 2 etc There may be gaps in the numbering if for example a not all the possible readers are installed on a particular door controller Zones Zzzzz Zone Number zzzz 000...

Страница 6: ...ates are sent for two minutes 4 1 Dialback The door controllers on the remote sites may have been configured by your installer such that in the event of an alarm occurring at the remote site they will initiate a communications session dial back to the CNC This feature is not programmable from the administration software only from the door controller itself The duration of a dial back session will ...

Страница 7: ... Re dialing Line Unobtainable Comms Error 18 Although communications was established with the remote modem the CNC was unable to communicate with the Readykey door controller at the remote site This type of error is reported to Readykey for Windows as D C Not Responding 5 3 3 Priority 2 Updates On line SITE sss nnnnn or SITE sss nnnnn This display indicates that the CNC is storing nnnnn updates wa...

Страница 8: ...l remain until acknowledged with a valid operator key Even once an alarm has been acknowledged at the CNC it will need to be acknowledged again at the PC when it is again able to receive alarm events 5 4 1 Priority 1 Alarms Note These messages will be shown scrolling on the CNC display A full description of alarm messages is shown below The different alarm messages are Ssss Dddd DOOR FORCED ALARM ...

Страница 9: ...bove message indicates that the person with ID iiiii has indicated a duress on door ddd on site sss ID numbers are shown as Record Numbers in the Readykey for Windows Personnel application 7 0 Clock Synchronize All events transactions that occur on a Readykey for Windows system are time and date stamped as they occur to allow a history to be viewed printed or searched on Transactions that are gene...

Страница 10: ...ITE sss nnnnn where nnnnn is not 00000 then you will need to perform a force dial operation for each site Use the Readykey Engine display as described on page 5 to determine the site names in Readykey for Windows for the site numbers displayed on the CNC A force dial operation is done from within the Installer application select the Force Dial option found under the Utilities menu Choose the Site ...

Страница 11: ...me for the second phase is dependent on the speed and type of communications link in place between the CNC and the site During the first stage Readykey for Windows will indicate the Complete and the CNC will display an increasing update count of the form SITE sss nnnnn When the Complete reaches 100 then a Download Complete message on the PC will be shown It is important to realize that it is only ...

Страница 12: ...K6100 CNC 2001 Radionics a division of Detection Systems Inc PO Box 80012 Salinas CA 93912 0012 USA Customer Service 800 538 5807 17317 Ver 1 2 48569B User Guide K6100 CNC Page 12 of 12 Notes ...