74-07579-000-A 2/96
Page 16
© 1996 Radionics, Inc.
Printer example:
Date
Time
Door
User
Transaction
[0123]
12/06/95
10:34
1
0092
Access Authorized
[0124]
12/06/95
10:35
2
Request to Exit
[0125)
12/06/95
10:50
2
Manual Unlock
[0126]
12/06/95
13:30
1
Automatic Unlock
Note:
The remaining displays described in this section are only applicable to the
Easikey 1000 Plus version of the door controller.
Door Left Open Warning (Easikey 1000 Plus Only)
The EK1000 Plus door controller only gives this warning if you are using door
monitoring. If a door is left open longer than the time set then the
dt
, door open
time described later in Door Programming,
Op
will start to flash on the display of
the EK1000 for the particular door left open. The
Op
will continue to flash until the
door is closed. There is no sound associated with this warning.
Printer example:
Date
Time
Door
User
Transaction
[0233]
12/06/95
12:34
1
Door Left Open
[0234]
12/06/95
12:35
1
Door Closed
Unauthorized Access Alarm (Easikey 1000 Plus Only)
The door controller only gives this alarm if you are using door monitoring.
If someone opens a door without using a key/card, Time Profile being active,
Manual Unlock used, or a Request to Exit button being pressed then the
controller interprets this condition as Editor key/card, either the Master or a Sub
Editor, to the EK1000's internal reader.
This alarm gives exactly the same displays and sounds as Cable or Reader
Tamper (described next). However, the printed reports are different.
Display:
AL
, Flashing
Sound:
Every two seconds
Cause:
Unauthorized Access of
Cable/Reader Tamper.
Silence:
Present editor key/card
to the EK100's internal reader to
accept, and the alarm condition
sound will stop.
Display:
AL
, Steady
Sound:
Silent
Cause:
Accepted Alarm or Cable/Reader Tamper.
The alarm condition still exists, either the door is still open or the cable/reader is
still tampered.