D279A Operation & Installation Guide

46456B

Page 10

Copyright © 2000 Radionics

D279A

2.

Connect the D279A to the panel and protective zones or points as shown in Figure 2.

Install a 1 k

W

 EOL beyond the last sensor of both the 

Delayed

 and 

Instant

 loops to provide a

reference for supervision.

No terminating resistor is needed on the 

Burglary

 or 

Panic outputs

 to the panel.

If the 

Panic 

and

 Burglary

 outputs are connected to the same zone or point, place the J4 jumper on the

bottom two pins (see Figure 3).

If the 

Panic

 outputs from several Independent Zone Controls are connected to the same zone or point,

place the J4 jumper on the bottom two pins (see Figure 3) on all but one D279A.

Burglary and panic outputs

:  You cannot connect D279A Burglary and Panic outputs to the D6112 or

D4112 powered loop inputs. Powered loop inputs are D6112 Terminals 16, 17, 18, and 19;  D4112
Terminals 16 and 17; and D7112 Terminals 23 and 24.

3.

Route the 10-wire color-coded cable through the opening in the back of the enclosure base. Rotate the
conductor so that the red wire (PIN 1) is pointing toward the bottom of the keypad and the orange wire (PIN 10)
is pointing toward the top. Plug the connector into the back of the enclosure.

4.

Place the enclosure base on the wall in the desired location, and mark the locations of the mounting holes.
(The base can be mounted to a single-gang wall box. The two mounting screw holes in the base of the D279A
are positioned for standard single-gang compatibility.)  Secure the enclosure base to the wall or gang box.

5.

Push each key on the keypad towards the top of the enclosure to ensure proper mating with the openings in
the top cover.

6.

Align the top two tabs of the enclosure cover with the top two tab slots in the enclosure base. Slide the top of the
cover into the base. Gently push the bottom of the cover down on the base until it snaps into place.

7.

Program the passcode (see section 5.1 

User Passcode).

3.2

Connecting the D279A to the D55 Desk Stand

The wiring cable (with modular plug) that is included with the Desk Stand is not compatible with the D279A. To
install a D279A onto a D55 Desk Stand:

1.

Remove the cover as described previously.

2.

Plug the 10-wire cable into the D279A.

3.

Route the cable through the hole in the desk stand.

4.

Screw the base to the Desk Stand, and replace the cover.

To disconnect the D279A, reverse this procedure. The D279A cable plug cannot be removed through the Desk
Stand hole.

Installation

Содержание D279A

Страница 1: ...D279A Independent Zone Control I Z C Operation and Installation Guide R DELAYED INSTANT ARMED 3 2 1 5 6 4 8 9 7 fi Radionics ...

Страница 2: ...D279A Operation Installation Guide 46456B Page 2 Copyright 2000 Radionics D279A ...

Страница 3: ...tput 11 4 8 Panic Alarm Function 11 4 9 Relay Output 11 4 10 Delayed LED 11 4 11 Instant LED 11 4 12 Armed LED 11 4 13 Buzzer 12 4 14 Lighted Keys 12 5 0 Programming 13 5 1 User Passcode 13 5 1 1 Recovering the Standard Passcode 13 5 1 2 Programming or Changing the Passcode 13 5 2 Programming the D8112 Panel Protective Zone 14 5 2 1 Supervised Independent Zone Controls Opening and Closing Reports ...

Страница 4: ... Figure 1 Installing the D279A 9 Figure 2 Wiring the D279A 9 Figure 3 D279A Printed Circuit Assembly 13 Tables Table 1 D279A Independent Zone Control Operation and Installation Guide Organization 5 Table 2 Referenced Literature 5 Table 3 D279A Spefications 7 Table 4 Recommended D8112 Zone Codes 14 ...

Страница 5: ...ture Radionics Part Number D4112 Installation and Programming Manual 73 05365 002 6112 Main Program Entry Guide 74 04367 000 8112 Main Program Entry Guide 74 03762 000 9000 Series Program Entry Guide 74 07695 000 Table 2 Referenced Literature 1 3 Documentation Conventions 1 3 1 Type Styles Used in this Manual We use special type styles to help you identify the objects that we are describing in thi...

Страница 6: ...ns it may cause interference to radio and television reception It has been type tested and found to comply with the specifications in Sub part J of Part 15 of FCC rules for Class B Computing Devices If this equipment causes interference to radio or television reception which can be determined by turning the equipment on and off the installer is encouraged to correct the interference by one or more...

Страница 7: ...t Requirements Keypad Idle 60 mA Keypad lighted buzzer on both loops faulted and relay activated 104 mA Auxiliary Relay Rating Form C contacts 12 VDC 2 A max Dimensions H x W x D 4 6 x 8 2 x 0 816 in 11 6 x 20 7 x 0 2 cm Wiring A 10 wire quick connect plug in cable is provided for interfacing the D279A with the Control Communicator and the protective loops 22 AWG 1 2 mm or heavier gauge wire requi...

Страница 8: ...D279A Operation Installation Guide 46456B Page 8 Copyright 2000 Radionics D279A Overview Notes ...

Страница 9: ...CHED Figure 1 Installing the D279A 1 Remove the front cover from the enclosure base see Figure 1 above Use a small flat blade screwdriver to gently push the two bottom cover tabs back As the tabs are pushed back lift the bottom of the cover away from the base Remove the cover Figure 2 Wiring the D279A Circled numbers represent terminals on control panel J4 JUMPER POSITION FOR SINGLE ZONE CONNECTIO...

Страница 10: ...re PIN 10 is pointing toward the top Plug the connector into the back of the enclosure 4 Place the enclosure base on the wall in the desired location and mark the locations of the mounting holes The base can be mounted to a single gang wall box The two mounting screw holes in the base of the D279A are positioned for standard single gang compatibility Secure the enclosure base to the wall or gang b...

Страница 11: ...ring the passcode arms and disarms the D279A 4 7 Burglary Alarm Output Opening or shorting the delayed or instant loop while the D279A is armed causes the output to short the panel zone after entry delay on delayed loop or point for a minimum of three seconds 4 8 Panic Alarm Function Simultaneously pressing both asterisk buttons shorts the Panic output and initiates an alarm Panic outputs from sev...

Страница 12: ...arm occurs or the D279A is disarmed If you press a numbered key while the D279A is disarmed and a loop is faulted the buzzer indicates that the D279A is not ready to arm The D279A can only be armed if both loops are normal 4 14 Lighted Keys The D279A keys light during the entry delay period and when you press number keys or the command bar Operation ...

Страница 13: ...If you make a mistake while programming restart the procedure from Step 2 If programming is not completed in 60 seconds the Independent Zone Control reverts to the old passcode As shipped the J3 jumper plug is placed across the top two pins which enables passcode change see Figure 3 The passcode change W1 J3 J4 CUT JUMPER W1 FOR D8112 OPENING AND CLOSING REPORTS IF PANIC BURGLAR OUTPUTS ARE CONNEC...

Страница 14: ...nd closing reports are not transmitted from the zone controlled by the D279A Programming 5 2 3 Priority Zone Functions Programming the D279A as a priority zone enables two valuable functions When the zone code for the D279A is programmed with a 3 4 7 or 8 in the fourth digit position the IZC zone must be armed before the system can be master armed However once the D8112 is armed the D279A may be a...

Страница 15: ...ripped while armed The D4112 or D6112 must be programmed with a bell time and the zone code must be programmed for audible alarms 5 5 Programming the D9112 for the D279A The D279A can be used in one of two ways with the D9112 The D279A controls arming disarming and entry exit delay for the point input it s connected to If the W1 jumper is cut point opening and closing reports may also be sent In t...

Страница 16: ...rt SHORT The point is in Alarm when the D279A is armed and is in Trouble when the D279A is Disarmed This will allow supervision of the wiring between the D279A and the panel A D279A programmed for non priority does not affect the assigned area when armed See the 9000 Series Program Entry Guide 74 07695 000 for more information 5 6 2 Assigning the D279A to a Point with Index 18 The Point Response m...

Отзывы: