D2212 Installation Manual

Page  13

© 1996 Radionics

74-07361-000-C 11/11/96

Optional Compatible Equipment

You can use UL listed components that do not require evaluation for
electrical compatibility in many applications when installed according
to the manufacturer’s instructions.

Burglary Applications

You can use UL listed burglary alarm sensors that do not require
evaluation for electrical compatibility in burglary applications. In
some cases you must use a UL listed Radionics interface module in
conjunction with the sensors. Consult the individual component
specification and installation documents to determine suitability.

In burglary applications with one 7.0Ah, 12 VDC battery the panel
supports an auxiliary output of 1 A and an alarm (bell) output of
1.85A configured as necessary. For additional loadings refer to the
Current Rating Chart for Standby Battery Calculations.

For commercial burglary installations use a maximum of 45 seconds
of entry delay and a maximum of 60 seconds of exit delay.

Test weekly:  UL Standard 1023 requires a weekly test. Configure
the User System Test to test the battery. See 

User Configuration in

the 

D2212 Program Entry Guide for instructions.

Fire Applications

You can use UL listed fire initiating devices not requiring electrical
compatibility evaluation in any application. For example: four-wire
smoke detectors, heat detectors, waterflow switches, and manual
pull stations are suitable fire initiating devices. Consult the individual
component specification and installation documents to determine
suitability.

When using four-wire smoke detectors, install a suitable power
supervision unit according to the manufacturer’s instructions. Use
the D133 Relay Module to provide reset capability.
In fire applications with one 7.0Ah, 12 VDC battery the panel
supports an auxiliary output of 140mA; it supports a total combined
continuous and alarm current daw during alarm conditions of 1 A.
For additional loadings refer to the 

Current Rating Chart for Standby

Battery Calculations.

Two-wire detectors must be electrically compatible, and must be UL
listed for use with the D2212. See the Radionics Technogram
Smoke Detectors Compatible with the D2212 (73-07358-000), or
you may contact the detector manufacturer.

Test weekly:  Radionics recommends testing fire and combined fire/
burglary systems weekly. Configure the User System Test to test the
battery. See 

User Configuration in the D2212 Program Entry Guide

for instructions.

For all Burglary applications the panel must be programmed to send
a supervisory signal to the central station a minimum of once every
24 hours.

Do not set or program an automatic telephone dialer or similar
device to place a call to a police station number that is not
specifically assigned by that station for such service.

Sounding Device

The sounding device shall operate for at least four minutes before
an automatic cutoff for Household Burglary applications and at least
15 minutes for Commercial Burglary applications.

For all Commercial Burglary applications the system must be
programmed to sound the audible device every time the system is
armed.

Enclosures

The D2203 enclosure is suitable for Household Fire and Burglary
applications only.

Enclosure tamper protection causing an immediate alarm signal is
required for all burglary applications.

Radionics offers three optional enclosures.

The D8103 enclosure is suitable for residential fire and/or burglary
installations and commercial applications. See System Chart for
acceptible applications.

The D8109 is normally used for fire alarm applications. The D8109
is approved by Factory Mutual, California State Fire Marshal, and
the New York City Materials and Equipment Acceptance System.

The D8108A is attack resistant. It is intended primarily for UL
commercial burglary alarm and mercantile safe and vault
applications requiring a local bell. You can use the D8108A in any
burglary application where the D8103 or D8109 enclosure is
suitable. The D8108A is approved by Factory Mutual, California
State Fire Marshal, and the New York City Materials and Equipment
Acceptance System.
The D2212 control panel is suitable for Police Station connect
applications, including Grade A Mercantile Premises and Grade A
Mercantile Safe and Vault alarm systems. Suitable for Grade AA
Mercantile Premises and Grade AA Mercantile Safe and Vault alarm
systems when the Model D2212 DACT unit is installed in
conjunction with the Model D8122 derived channel subscriber
terminal unit. For all Police Station applications and grades, the
Model D8108A Attack Resistant Enclosure with a UL Listed local
sounding device is required. Per UL 365, keyswitches mounted
outside the protected area must employ high security locking
cylinders complying with the requirements for key locks, UL 437.
Tamper protection must also be provided.

The D2212 control panel is suitable for Local, Grade A Mercantile
Premises and Local, Grade A Mercantile Safe and Vault alarm
systems. For all Local applications and grades, the Model D8108A
Attack Resistant Enclosure and a UL Listed local sounding device
are required. Per UL 609, when keyswitches are mounted outside
the protected area, tamper protection must be provided.

The D2212 control panel is suitable for Central Station, Grade C
applications. It is suitable for Central Station, Grade B applications
when the Model D2212 DACT unit is installed with a UL Listed local
sounding device. Also suitable for Central Station Mercantile, Grade
AA applications when installed with the Model D8122 derived
channel subscriber terminal unit.

Installation Guide for UL

Applications

Introduction

The 

System Chart references components evaluated and listed by

Underwriters’ Laboratories for compatibility with the panel. These
components meet the basic system requirements for the applicable
standard.

The 

System Wiring Diagram, Issue A  shows the relationship

between the panel and the accessory components referred to in the
System Chart. See the installation and operation instructions for
each component for detailed instructions.

www.PDF-Zoo.com

firealarmresources.com

Содержание D2212

Страница 1: ...74 07361 000 C 11 11 96 1995 1996 Radionics D2212 Control Communicator Installation Manual www PDF Zoo com firealarmresources com ...

Страница 2: ...Communicator for connection to the public telephone network using an RJ38X or RJ31X jack Use the ringer equivalence number REN to determine the number of devices you can connect to the telephone line Excessive RENs on the telephone line may result in devices not ringing in response to an incoming call In most but not all areas the sum of the RENs should not exceed five 5 Contact the telephone comp...

Страница 3: ...es the following D222 Text Keypad with Point Expansion 4 points Installation Sheet 74 07362 000 User s Reference Card 71 04523 010 Security System User s Guide 71 07374 000 Getting Started w Your Security System 71 07372 000 Three wire data cable assembly 15 07032 000 Six wire point cable assembly 15 07251 000 Four 1k Ω end of line resistors 30 01098 102 Table of Contents Introduction 3 D2212 Cont...

Страница 4: ...ing Started w Your Security System 71 07372 000 Three wire data cable assembly 15 07032 000 Battery Order a D126 Battery 12 V 7 0Ah to complete a basic D2212 installation Enclosure Options The D2212 is shipped in the D2203 enclosure If you want to mount the D2212 in one of the optional enclosures listed below order the D2212M and the enclosure of your choice D8103 Universal Enclosure D8108A Attack...

Страница 5: ...wire maximum under the terminal Use a spade lug or splice for larger wire Do not connect any other panel terminals to earth ground The panel s common terminals and terminal 3 earth ground are electrically isolated Transformer Terminals 1 and 2 Connect the transformer to terminals 1 and 2 on the panel before plugging it into the power source Use 18 AWG wire to connect the transformer to the panel W...

Страница 6: ...using Point 1 as a fire point the number of detection devices you can connect to its sensor loop is limited See Point 1 on Page 7 The number of detection devices you can connect to the sensor loops for points 2 to 8 is limited only by the resistance on the loop Resistance must be less than 100Ω with the detection devices connected Continue Connections to the Panel Power Down First Unplug the trans...

Страница 7: ...onnections Warning Do not connect wiring for external devices directly to terminals 11 or 12 Install D133 D134 modules connected to terminals 11 and 12 in the enclosure with the panel as shown in Figure 1 The D133 draws 36mA when energized When both relays are energized the D134 draws 72 mA Connect the Points On Board Points Point 1 Terminals 13 and 14 Point 1 on the D2212 is a powered supervised ...

Страница 8: ...oint wiring Four Wire Smoke Detectors Connect any number limited by available power and the Authority Having Jurisdiction of 12 VDC four wire smoke detectors to any supervised point Install a suitable power supervision device according the manufacturer s instructions Route the power for the detectors through a D133 D134 Relay Module The relay module must be connected to one of the panel s external...

Страница 9: ...dular Phone Jack Premises Phone RJ31X Module Figure 6 RJ31X Phone Jack Program Entry Guide for programming options and keypad programming instructions If you re programming from the keypad or using the D5200 make sure the Standby Switch is locked down See Figure 8 If you re using the D5200 Figure 9 shows the location of the programming jack See the D5200 Programmer Operation Manual for instruction...

Страница 10: ...0 VDC Battery restoral reports sent the keypad returns to normal operation 13 9 VDC Battery float charged Fill out the Point Chart Radionics recommends that you fill out the Point Chart on the Installation Label located on the inside of the D2203 Enclosure cover You must fill out the point chart if you programmed Point 1 for Fire with Verification Digit 1 2 See POINT CODES in the D2212 Program Ent...

Страница 11: ...ch the receiver 10 attempts if two phone number are programmed the panel goes into communication failure The panel clears any reports in its phone buffer The panel sounds a tone at the keypad indicating trouble Pressing the Clear key silences the tone When communication restores a report is acknowledged by the receiver the keypad returns to normal operation Ground Start Some telephone systems requ...

Страница 12: ...Shorted Loop Greater than 0 0 VDC but less than 2 0 VDC Points 7 and 8 Points 7 and 8 are not supervised with EOL resistors Open Loop Greater than 2 4 VDC but less than 13 9 VDC Normal Closed Loop Greater than 0 0 VDC but less than 1 4 VDC Point Response Time The panel scans point sensor loops every 500 milliseconds A point must be faulted for 2 scans one second before the panel initiates an alarm...

Страница 13: ...5 minutes for Commercial Burglary applications For all Commercial Burglary applications the system must be programmed to sound the audible device every time the system is armed Enclosures The D2203 enclosure is suitable for Household Fire and Burglary applications only Enclosure tamper protection causing an immediate alarm signal is required for all burglary applications Radionics offers three opt...

Страница 14: ...electronic vibration sensor directly inside the metal cabinet of the D8108A Do NOT install the sensor within a quarter inch 1 4 of the components or traces of the printed circuit assembly System Chart Household Burglar Grade A Household Fire Household Fire Burglary Combined Central Station Burglary Grade C Police Connected Burglary Local Burglary Proprietary Burglary NFPA Standard 72 72 Min Hours ...

Страница 15: ...es System Wiring Diagram Issue A s s P P P D164 Phone Cord to RJ31X for Phone Line Listed Audible Signaling Device Rated At 10 2 TO 13 9 VDC Do NOT Use Vibrating Type Horns P P P P D133 D134 Relay P P Supervised with 1k Ω EOL Resistor Typical Initiating Devices are Door Contacts NO NC Floor Mats Motion Sensors Glass Break Detectors etc NOT Supervised Normally Closed Typical Initiating Devices are ...

Страница 16: ...moke Detector Head D208 RF Receiver D216 RF Receiver Radionics Inc 1800 Abbott Street Radionics 1 Park Gate Close Bredbury Salinas California 93901 Stockport Cheshire SK6 2SZ England Customer Service 800 538 5807 Technical Support 061 494 0851 The Radionics logo is a registered trademark of Radionics Inc Salinas CA U S A 1995 Radionics Inc Salinas CA U S A All rights reserved D2212 Terminal Quick ...

Отзывы: