2. Debug/Status information

3. Parameter configuration

Notice!

Each time the device is connected, the parameters will be automatically obtained once and sent

to the computer.

All parameters must be written after modification. Click "Optimset" in the lower right corner,

otherwise the parameters will not be set successfully.

(1) CAN Timing

Preset baud rate selection: After selection, BS1, BS2, BRP, and SJW parameters will be

automatically set. When the preset value does not meet the requirements, parameters of BS1,
BS2, BRP, and SJW can be manually adjusted according to the actual situation.

BS1(TSEG1): Bit segment 1

BS2(TSEG1): Bit segment 2

BRP: The duration of one time quantum

SJW: (Re)synchronization jump width (The larger the value is set, the larger the baud rate error

is allowed.)

Содержание RTC8

Страница 1: ...RTC8 SBUS PPM to CAN Protocol Encoder...

Страница 2: ...1 Contents Chapter 1 Overview 2 Chapter 2 Specifications 3 Chapter 3 Main Functions 3 Chapter 4 Driver installation 4 Chapter 5 Firmware update 5 Chapter 6 SBUS PPM to CAN Explorer 6...

Страница 3: ...e mode 4 Power Indicator Lights up in green after the encoder is powered on 5 USB connector 1 Connect with computer for parameter adjustment and data observation 2 Update the firmware after connecting...

Страница 4: ...ication baud rate can be freely programmed between 5Kbps 1Mbps 5 Powered by USB 5 15V 6 The received data flow rate is up to 100fps 7 Support Windows 7 8 9 10 and other Windows systems 8 Support SBUS_...

Страница 5: ...Chapter 4 Driver installation 1 Use a USB cable to connect the SBUS PPM to CAN Protocol encoder to the computer 2 After the successful connection there will be a new COM port in computer device manage...

Страница 6: ...o be formatted and you can directly close the window 3 Open the firmware upgrade software 1 Select the disk that just popped up 2 Select the firmware to be updated 3 Write the program and it will pop...

Страница 7: ...atus information display 1 CAN Display currently received CAN data after filtering ID 2 SBUS If there is an SBUS signal input the SBUS channel data will be displayed 3 PPM If there is a PPM signal inp...

Страница 8: ...eters will not be set successfully 1 CAN Timing Preset baud rate selection After selection BS1 BS2 BRP and SJW parameters will be automatically set When the preset value does not meet the requirements...

Страница 9: ...Get 8byte_1 ID and send 8 data 1 4 channels 2 bytes per channel 3 Respond after receiving Get 8byte_2 ID and send 8 data 5 8 channels 2 bytes per channel 4 Respond after receiving the Get 8byte_3 ID...

Страница 10: ...as follows The meaning of each bit in Filter Mask ID 1 Bit x is set to 1 and the bit x of the received ID must be consistent with the bit x of the Filter ID otherwise it will be ignored 2 Bit x is set...

Страница 11: ...User Mode Parameters 1 Length User defined data sending length 2 Remote Request 3 Cycle Time The cycle of automatically sending channel data 4 AutoSender Automatic sending mode When AutoSender is tic...

Отзывы: