RadioLink Electronic Ltd
3
Press EXIT and ENTER simultaneously to enter MENU=>press Inc(+) to highlight “19. ALARM =>Press
ENTER to set the model battery voltage warning value.
Normally we set the warning value with the single cell voltage as 3.7V. For example, if it is 3S lithium
battery used in the model car, the warning value should be set as
(
3.7V*3S=
)
11.1V.
Model battery voltage telemetry can be easily achieved by connecting the male end of the battery wire to
ESC while the female end to the battery and the wire with a JST head connects BAT (+-) of R7FG/R8F as
below pic shown. No extra module is needed.
When connect with success, users can check the battery voltage on the
main interface of the transmitter.
III. Subsidiary ID
Subsidiary ID
function means designating a subsidiary ID among multiple binding receivers to realize the
control and it can be realized by on the ID seed menu of RC6GS(3-way switch version with latest
firmware V6.0.0) or RC4GS(Produced after 20180101 with the latest firmware V6.0.1). There are totally
10 independent subsidiary IDs can be stored in a transmitter..
For example, RC6GS has completed the binding with 10 different boats and the setup of respective
parameters. Turn on the ID SEED function, select ID.1 boat and drive it to the central of water but it stops
working unexpectedly. Then we can change to the ID.2 boat (or any other subsidiary ID boat preferred)
and control it independently to rescue ID. 1 boat instead of controlling both boats at the same time, which
makes the rescue more difficult. Unlike traditional binding mode, independent ID can easily realize
Battery
Telemetry cable
Motor
ESC
R7FG
Servo