PULSE WIDTHS
Enables the various pulse widths available on each range to be selected. The
pulse widths are either automatically selected (AUTO) or set to a specific
value (MANUAL) via the HELP menu.
HORIZONTAL EXPANSION (ZOOM)
Enables the trace about the solid cursor to be expanded by factors of 2, 4 and 8,
depending on range selected (see Section 7.7 and Section 12, Specification for
further details).
OPERATION
Selects the operating mode (see Section 6 for further details).
DIELECTRIC
Used to set the appropriate velocity factor for the cable dielectric. The value
will increment or decrement. If held down the value changes slowly at first and
then quickens. Also act as numbers 6 and 11.
RANGE
Selects the displayed range. The range will increase or decrease and if held
down will step through the available ranges. Also act as numbers 7 and 12.
Radiodetection Ltd. 00901209-6
T631 OPERATING MANUAL
12