background image

8

Locating pipes with a sonde

For more detailed descriptions of using 
the locator, and for detailed sonde 
locate techniques, refer to the RD5100S 
Operation Manual.

Make sure the sonde frequency matches 
the selected locator sonde frequency.

Note: The 'blade' of the locator must 
be in-line with the central axis of the 
sonde.

A new battery or a freshly recharged battery should be used at the beginning of each 
day and preferably at the start of a job. Check that the locator and sonde are working 
correctly.
A quick test for both sonde and locator is to position the sonde at ground level at a 
distance equal to its rated depth range from the locator. Point the locator at the sonde 
with its blade in-line with the sonde, and check that the bar graph on the locator 
displays more than 50% with the sensitivity of the locator set to maximum.
With the sonde in place at the survey 
location, hold the locator vertically and 
directly over the sonde's estimated 
position. Make sure the blade is in-line 
with the sonde. Adjust the sensitivity 
(gain) of the locator to give a bar graph 
display reading between 60% and 80%.
A sonde radiates a peak radio frequency 
field from the center of its axis with 
weaker signal (ghost) lobes at each 
side. Ghost lobe identification helps to 
confirm the accuracy of the peak (center) 
position. Move the locator a little way to 
one side and then along the axis of the 
sonde iteratively forwards and backwards 
to detect the ghost lobes. Reduce the 
sensitivity of the locator until the ghost lobes are no longer detected.
With the locator sensitivity set as desired, propel the sonde along three to four paces 
and stop.

Содержание RD5100 S

Страница 1: ...RD5100 S Multifunction precision cable and pipe locator User Guide PART NO 90 UG111INT 01 ...

Страница 2: ...tempted by fully qualified personnel only using the relevant products that allow connections to energized lines WARNING The optional transmitter is capable of outputting potentially lethal voltages Take care when applying signals to any pipe or cable and be sure to notify other technicians who may be working on the line WARNING Risk of Hearing Loss The locator emits noise levels which can cause pa...

Страница 3: ...nd their warranty period to a total of 3 years by registering their products within 3 months of purchase Visit https portal radiodetection com to create your company portal account and use the Product page to register your locator or transmitter Information on how to create a company account can be obtained from https support radiodetection com From time to time Radiodetection may release new soft...

Страница 4: ...4 RD5100S locator 1 2 3 4 5 7 6 8 10 12 11 9 ...

Страница 5: ...ons 13 Signal strength bargraph with peak marker 14 Signal strength readout 15 Proportional Guidance arrows 16 Battery level 17 Sensitivity readout 18 Frequency readout 19 Sonde icon Indicates that a sonde signal source is selected 20 Compass Shows the orientation of the located sonde relative to the locator 21 Antenna mode icon Indicates antenna mode selection Guidance Peak 22 Line icon Indicates...

Страница 6: ... Switch between Guidance and Peak with guidance arrows Set gain to mid position and increases gain in 1dB increments in Peak mode Rapidly increases gain in 1dB increments in Peak mode Set gain to mid position and decreases gain in 1dB increments in Peak mode Rapidly decreases gain in 1dB increments in Peak mode Note i Configuration dependent Tip Gain values set for each sonde frequency are stored ...

Страница 7: ...negative terminals as indicated Rechargeable battery packs Lithium Ion battery packs are available for the locator providing superior performance over traditional alkaline batteries To fit these rechargeable packs follow the instructions provided with each pack Checking the system software version and last calibration date To check which version of software is running on your locator and the date ...

Страница 8: ...nde and check that the bar graph on the locator displays more than 50 with the sensitivity of the locator set to maximum With the sonde in place at the survey location hold the locator vertically and directly over the sonde s estimated position Make sure the blade is in line with the sonde Adjust the sensitivity gain of the locator to give a bar graph display reading between 60 and 80 A sonde radi...

Страница 9: ...isplay indicates a clear peak response 4 Repeat Steps 1 to 3 in smaller increments with the locator blade resting on or near the ground The locator should now be directly above the sonde with the blade in line with the sonde Now mark the position 5 Propel the sonde a further three to four paces along the drain or duct and pinpoint and mark Repeat this procedure along the route at similar intervals...

Страница 10: ...locator This helps you to make sure that you are following the right pipe especially when other utilities are present The RD5100S locator features TruDepth a feature that helps you to ensure the accuracy of your locates The depth is automatically removed from the display when the locator is at an angle of more than 7 5 from the path of the pipe being located or when the locator determines that sig...

Страница 11: ...on sockets are clean free of debris and corrosion and are undamaged Do not use this equipment when damaged or faulty Batteries and power supply Only use the rechargeable battery packs chargers and power supplies approved by Radiodetection If not using rechargeable packs use good quality Alkaline or NiMH batteries only Batteries should be disposed of in accordance with your company s work practice ...

Страница 12: ...rformance Service and maintenance Regulary check your equipment for correct operation by using eCert The locator and optional transmitter are designed so that they do not require regular recalibration However as with all safety equipment it is recommended that they are serviced and calibrated at least once a year either at Radiodetection or an approved repair center NOTE Service by non approved se...

Страница 13: ......

Страница 14: ... Radiodetection Canada 344 Edgeley Boulevard Unit 34 Concord Ontario L4K 4B7 Canada Tel 1 905 660 9995 Toll Free 1 800 665 7953 rd sales ca spx com Radiodetection Ltd UK Western Drive Bristol BS14 0AF UK Tel 44 0 117 976 7776 rd sales uk spx com Radiodetection France 13 Grande Rue 76220 Neuf Marché France Tel 33 0 2 32 89 93 60 rd sales fr spx com Radiodetection Benelux Industriestraat 11 7041 GD ...

Отзывы: