Selecting a power output level
•
Select the required frequency.
•
Press the up arrow key to select a higher output level and press the down arrow to select a lower output
level. The power output indicator will display a visual indication of achieved output level.
Output levels for each segment of the indicator are shown in the following table:
NUMBER OF
SEGMENTS
Direct -
Locate
Direct - ACID
Direct -
FaultFind
Ind All
Others
Outline
10mA
1 bar
30mA
30mA
(25%)
2 bar
60mA
3 bar
100mA
100mA
Normal
(50%)
(50%)
4 bar
200mA
5 bar
400mA
400mA
(75%)
6 bar
700mA
7 bar
1A
1A
Boost
(100%)
(100%)
Note: If the transmitter is outputting less than 10mA the display flashes “10mA” to indicate that better
connections are required.
Selecting induction
Ensure that there is not an accessory plugged into the transmitter. Switch the transmitter on. Induction mode is
automatically selected and the induction mode symbol is displayed. There can be two induction frequencies
available in the RD4000T10. Use the frequency key to select the induction frequency required.
Using the V
Ω
function
In locate mode the line output voltage can be measured by pressing and holding down the V
Ω
key.
In measure mode DC resistance on the line can be measured by pressing and holding down the V
Ω
key.
Measure mode can be used for frequencies up to dc 200KHz on lines up to 30V (SELV) only.
To access measure mode and take a resistance reading:
•
Press on/off to select the menu and scroll using the down arrow to select Measure.
•
Press on/off again to confirm selection.
•
Press and hold down the measurement key to select ohms and take a resistance reading.
Selecting FF mode
•
Switch the transmitter on
•
Ensure the direct connection leads are plugged in
•
Press the menu key and press the up or down arrow until ‘FaultFind’ is displayed.