Radiocrafts RC2301DK Скачать руководство пользователя страница 3

Radiocrafts

Embedded Wireless Solutions

    

RC2301DK

 

 

 
 
 

©

2007 Radiocrafts AS 

RC2301DK Demonstration Kit Quick Start (rev. 2.0) 

Page 3 of 4 

 

 
 

4. Power up reference nodes

 

Connect power to reference node 1 (R1). Make sure that it is in range of the location dongle.  
The reference node will appear in the Reference Node Setup tab in the application, and will 
also appear in the graphical window as a yellow ball. 
 

 

Figure 4. Reference Node Setup tab 

Double-click on the node in the list and change the location coordinates. Press update. 
Status of the device will be 

updating.

 When the update is complete, double-click the node 

again to make sure the updating was successful. Then place the node at the specified 
location. 
 
Repeat for nodes R2 to R6. 
 
 

5. Activate blind node 

Activate the blind node by connecting it to a battery. After a few seconds the blind node will 
appear in the application window as a green ball.  
 
 

6. Tuning the application 

The application can be tuned by changing the parameters that the location engine in RC2301 
uses. This is done in the Blind Node Setup tab. Double-click on the blind node you want to 
change, set the parameters and press update. For a description of the parameters see the 

Содержание RC2301DK

Страница 1: ...ration kit shows a ZigBee ready location demo application on the Figure 8 Wireless Z stack from Texas Instruments To make the demonstration a minimum of 8 nodes are required One Location Dongle D configured as network coordinator Six reference nodes R1 to R6 configured as network routers One blind node B with RC2301 configured as network router The kit contains all 8 boards and each board has an i...

Страница 2: ...ect COM port field at the bottom of the application window correspond to the correct port The program does not support USB Com port only pure RS232 COM ports Press the button in the application and observe that the application connects to the dongle at the bottom of the application window Figure 1 Before connection Figure 2 After connection 3 Add a background image Select the Background tab in the...

Страница 3: ...oordinates Press update Status of the device will be updating When the update is complete double click the node again to make sure the updating was successful Then place the node at the specified location Repeat for nodes R2 to R6 5 Activate blind node Activate the blind node by connecting it to a battery After a few seconds the blind node will appear in the application window as a green ball 6 Tu...

Страница 4: ...tion Profile document by TI Document Number F8W 2006 0002 Some parameters of the application can also be tuned in the Settings window Contact Information Radiocrafts AS Sandakerveien 64 NO 0484 OSLO NORWAY www radiocrafts com radiocrafts radiocrafts com Tel 47 4000 5195 Fax 47 22 71 29 15 ZigBee is a registered trademark of the ZigBee Alliance 2007 Radiocrafts AS All rights reserved ...