Radio Thermostat CT30 Скачать руководство пользователя страница 5

PG

 4

PG

 5

PG

 5

Find the step-by-step diagram for your 

 

 

• Select the referenece 

page with your wiring 

diagram and set-up 

information below.

• The C-wire is optional but 

prefered for all installations 

[shown dotted in diagrams].  

Some radio modules will 

require the 24vac C-wire 

power.

• If your combination of 

wires is not above you can 

use the wiring table at the 

end if the install section to 

determine your connections, 

contact  

[email protected]

   

 

or 877-602-5028 for help.

G

C W Y RH RC G

 

5 Wire

Heat/Cool

From

 

Furnace

RC

C

Y RH

W

C W Y RH G 

4 Wire 

Heat/Cool

From

 

Furnace

G

C

Y RH

W

C W RH G 

3 Wire 

Heat

From

 

Furnace

C

RH

G

W

From

 

Furnace

C

W

C  W  RH 

RH

2 Wire 

Heat

From

 

Furnace

W RH

A

W  RH  A

 

3 Wire 

Zoned

Hot Water

 

 

W

IRES

WIRES

WIRES

WIRES

WIRES

G

RH

C W2 W Y Y2 R

H

 G

 

2 stage Cool

2 stage Heat

From

 

Furnace

Y

2

C

W Y

W

2

C B

 or 

O  W

2

 Y R

H

 G

 

5 Wire 

  Heat Pump

       w/ Aux Heat

From

 

Furnace

RH

C

O

or

W2

B

G

Y

G

C B

 or 

O  Y R

H

 G

 

4 Wire Heat Pump

w/o Aux Heat

From

 

Furnace

RH

C

O

or

Y

B

WIRES

WIRES

WIRES

Go To Page 13

Go To Page 13

Go To Page 14

Go To Page 14

Go

 To

 Page 16

Go To Page 15

Go To Page 15

Go To Page 16

from  

HVAC

from  

HVAC

from  

HVAC

from  

HVAC

from  

HVAC

from  

HVAC

from  

HVAC

from  

HVAC

Содержание CT30

Страница 1: ...s designed for use with 3AA alkaline batteries and or 24 volt AC C wire or a 12 24 AC or DC source and millivolt gas systems Each thermostat relay load should be limited to 1 0 amp higher amperage may...

Страница 2: ...there are unusual heating conditions such as in direct sunlight near a lamp radio television radiator register fireplace near hot water pipes in a wall or near a stove on the other side of a wall Do...

Страница 3: ...carefully before removing any wiring from existing thermostat Wires must be labeled before they are removed THERE IS NO STANDARD COLOR CODE When remov ing wires from their terminals ignore the color o...

Страница 4: ...a standard 12 24V AC or DC wall transformer A constant power source is required when using a radio module IMPORTANT If you have both RH and RC you need to remove the jumper wire between these 2 termin...

Страница 5: ...eat Cool From Furnace RC C Y RH W C W Y RH G 4 Wire Heat Cool From Furnace G C Y RH W C W RH G 3 Wire Heat From Furnace C RH G W From Furnace C W C W RH RH 2 Wire Heat From Furnace W RH A W RH A 3 Wir...

Страница 6: ...terminal area Do not bunch wires behind the CT30 Feed any slack back into the wall opening Connect Your Wires Connect labeled wires only to a terminal with the same letter label Insert the wire in the...

Страница 7: ...e CT30 to the wall with the screws provided 4 If you are mounting the CT30 to sheet rock or if you are using the old mounting holes use the plastic anchors provided 5 Mark first and drill a 3 16 in 4...

Страница 8: ...AA Batteries Install 3 AA alkaline batteries required following the marked polarity in the battery compartment Put the lower battery in negative end first against the spring then push the positive end...

Страница 9: ...r a month or more you should replace the batteries as a precaution against battery failure in your absence Always use new alkaline batteries Failing to replace the batteries when necessary could cause...

Страница 10: ...age HEAT 2 stage COOL select 3 If you want efficient but slower recovery 2 stage HEAT 1 stage COOL select 4 2 stage HEAT 2 stage COOL select 5 NOTE For 2 stage systems your CT30 can recover from a tem...

Страница 11: ...screen Touch the icon and raise the target temp to 90 o F allow the system 2 minutes to respond Verify that heat is blowing from the system Return the Target Temp to a nomal setting Return mode to OF...

Страница 12: ...heating It cannot be used with line voltage systems This thermostat is digital and your desired heat or cool temperatures can easily be set on the large touch screen with the buttons A minimum 4 minu...

Страница 13: ...Heat STEP 1 Connect the R or RH wire to the RH terminal This connects the heat power STEP 2 Connect the W wire to the W terminal This connects the heat STEP 3 Connect the G wire to the G terminal on t...

Страница 14: ...RH RC G WIRES 5 Wire Heat Cool STEP 1 Connect the W wire to the W terminal This connects the heat STEP 2 Connect the Y wire to the Y terminal This connects to the cooling compressor STEP 3 Disconnect...

Страница 15: ...he O or B wire to the B terminal This connects the change over valve If you have both O and B connect O wire to O terminal WARNING DO NOT connect B to B terminal see wire reference under Trane for B w...

Страница 16: ...the G terminal This connects the fan STEP 7 Set HVAC selection switches to NORMAL and If you have gas or oil heat set the HEAT TYPE to GAS If you have electric heat set the HEAT TYPE to ELEC Your HVAC...

Страница 17: ...e COOL control or 2nd stage compression for a heat pump G or F G FAN control C or X C 24VAC power to power thermostat NOTE TRANE uses B for this connection H H External Humidifier DH DH External De Hu...

Страница 18: ...thermostat W or W1 W2 2nd stage HEAT X2 Emergency heat do not connect tape off Zoned Hot Water 2 wire Your Wires Thermostat Terminal R RH W W 3 Wire Motor Driven Valves R or 5 RH power W or 4 W heat...

Страница 19: ...PG 19 Notes on your system...