CALIBRATE

     Your thermostat was accurately calibrated at the factory to ±1° F of actual ambient 

temperature. You do have the option, however, to change the display temperature to match that of a 

previous thermostat, or to match another thermostat already in your home. The range of change is 

from -6°F to +6°F or -3°C to +3°C.

 

To change your Thermostat Calibration, 

touch 

MENU

 and then touch 

CALIBRATE.

Use the + / -  to adjust the displayed temperature up or down, as desired. 

The DELTA FACTOR that appears on the screen will also automatically increase or decrease 

for each  0.5° (F or C) adjustment so you can see your change. The large display will show the 

modified temperature reading that will be displayed on the HOME screen and used as the new room 

temperature.
Touch 

 to return to the Home screen.

DIFF

 

(Used for multiple stage systems only, not on screen for single stage)  

The differential is the number of degrees between the room temperature and the Target Temperature 

at which the 2nd stage will be used. DIFF may be set to a different value for HEAT or COOL.  Default 

is 2°F , range is 2°F to 6°F  (1°- 3°C).

To set the differential for the current mode, touch MENU and then DIFF. Use the arrows to set the 

DIFF.   Recommend  2°F for very cold climates and 6°F for warm climates.

Содержание CT100

Страница 1: ...ISH Statement of use 100 Compatible with all popular residential HVAC systems 24VAC single two stage conventional heating systems gas oil electric heat pumps with up to two stages of heat and two stag...

Страница 2: ...arrows The HOME screen is displayed when the unit is operating Touching the HOME icon on another screen will always return you to this screen To set a Mode Press the MODE button on the front The CT10...

Страница 3: ...hermometer pg8 Set o C o F Touch this to set temp display units Lock Program Touch for 5 sec to lock or unlock RECOVERY set FAST or ECON RADIO icon Shows radio status and connection Chirp set Touch th...

Страница 4: ...on From the HOME screen touch the main temperature display to use this screen See page 9 for details F EMER HEAT Target Temperature Room Temperature Return HOME Temp Up Temp Down arrows Touch these to...

Страница 5: ...of Day arrows to move the time selection forward or backward until it displays the current time Touch and hold for faster setting Set oF oC display Touch the oF and it will toggle to oC Set audible ch...

Страница 6: ...d before the heating or cooling system will turn on Swing range 0 5 to 4 0 F 25 to 2 C For example if SWING is set to 2 0 F and the CT100 is set to 70 F Target Temperature the heat cycle will start wh...

Страница 7: ...an temporarily override the CT100 target with the buttons only 1 bar For FULL lock Touch the 1 bar icon again for 5 seconds to go to full lock No changes can be made in full lock 2 bars Once locked th...

Страница 8: ...ly increase or decrease for each 0 5 F or C adjustment so you can see your change The large display will show the modified temperature reading that will be displayed on the HOME screen and used as the...

Страница 9: ...select your desired Target Temperature Touch HOME to return to operation EMER in HEAT PUMP type If you set your CT100 for HEAT PUMP with auxiliary heat EMER function is available on the MANUAL screen...

Страница 10: ...manual override until switched back to AUTO by pressing the FAN button again NOTE Fan ON function is available in the OFF mode to allow simple ventilating RESET button The RESET button re boots the CT...

Отзывы: