22
Revised 4-21-10
ASSEMBLY 12009
ST BREAKOUT
+15V
+15V
-15V
+15V
-15V
-15V
SHIELD
SHIELD
SHIELD
JU1
JU6
JU4
JU9
JU8
JU3
JU2
JU7
JU5
R5
R3
J1
R6
R4
J3
R2
R1
J2
Part #
ADAPT-BO St Breakout Adapter
(856) 467-8000
•
Fax
(856) 467-3044
•
www.studiohub.com
These internal buses and jumpers allow
+15volts, –15volts and shield to be connected
from the two st RJ45(s) and the termi-
nal block.
A circuit path requires at least two jumpers.
JU1
install to tie terminal block shield
to internal shield bus.
JU2
install to tie terminal block –15volts
to internal –15volt bus.
JU3
install to tie terminal block +15volts
to in15volt bus.
JU4
install to tie St RJ45 J2
+15volts to in15volt bus.
JU5
install to tie St RJ45 J2
–15volts to internal –15volt bus.
JU6
install to tie St RJ45 J3
+15volts to in15volt bus.
JU7
install to tie St RJ45 J3
–15volts to internal –15volt bus.
JU8
install to tie St RJ45 J2
shield to internal shield bus.
JU9
install to tie St RJ45 J3
shield to internal shield bus.
2 St RJ45 with
pins below in parallel
1. Left + or AES/EBU+
2. Left – or AES/EBU–
3. Right +
6. Right –
4. Power Ground
5. Future