Radio Shack 63-1032 Скачать руководство пользователя страница 9

9

Preparation

2. Insert the tabs in the matching slots

on the thermometer’s base until they
snap into place. 

Note: Make sure the flat side of the base
faces the front of the thermometer.

To remove the stand, gently pull it away
from the unit.

Mounting the Thermometer

You need a wood screw (not supplied)
with a head that fits in the keyhole slot on

63-1032.fm  Page 9  Thursday, June 22, 2000  11:29 AM

Содержание 63-1032

Страница 1: ...Owner s Manual Please read before using this equipment In Out Thermometer with Indoor Humidity Gauge 63 1032 fm Page 1 Thursday June 22 2000 11 29 AM...

Страница 2: ...3 Line LCD Display displays the in door relative humidity and the indoor and outdoor temperatures in Celsius or Fahr enheit Minimum Maximum Memory lets you recall the lowest and highest indoor and ou...

Страница 3: ...eset it or replaced its batteries Temperature Compensation assures accurate indoor relative humidity mea surement unaffected by temperature changes Wet Dry Indicators appear when there is excess or in...

Страница 4: ...ration INSTALLING REPLACING BATTERIES Your thermometer hygrometer requires two AA batteries not supplied for power For the longest life and best perfor 3 Line LCD Display Memory Battery Compartment Re...

Страница 5: ...d new batteries different types of batteries standard alkaline or rechargeable or rechargeable batteries of different capacities 1 Press on the tab on the battery com partment cover and lift the cover...

Страница 6: ...ndoor relative humidity appear 3 Replace the cover If the display appears weak or the ther mometer does not work properly replace the batteries Cautions Never leave dead or weak batteries in the therm...

Страница 7: ...he thermometer on a lev el surface such as a desktop or counter using the supplied stand or you can mount it on a wall For the best mounting results attach the thermometer and outdoor sensor on dry wa...

Страница 8: ...r Do not try to remove it Avoid routing the outdoor sensor s cord where it could be pinched or cut Note Keep the thermometer and outdoor sensor away from artificial sources of heat or cold such as sto...

Страница 9: ...into place Note Make sure the flat side of the base faces the front of the thermometer To remove the stand gently pull it away from the unit Mounting the Thermometer You need a wood screw not supplie...

Страница 10: ...l 1 Mark the position of the screw hole 2 In the marked location drill a hole slightly smaller than the wood screw Caution Be careful not to drill into any objects behind the wall Keyhole Slot Screw O...

Страница 11: ...ter with the screw head then carefully push the ther mometer onto the screw head and slide it down into place Mounting the Outdoor Sensor You need a nail wood screw or masonry screw not supplied with...

Страница 12: ...w Caution Be careful not to drill into any objects behind the wall 3 Slide the wire bracket off the outdoor sensor 4 Push the nail or screw tip through the small loop on the wire bracket then drive th...

Страница 13: ...line and the indoor temperature IN in the second line Note If the outdoor temperature rises above 158 F 70 C or falls below 58 F 50 C the thermometer displays HHH or LLL in the first line Changing the...

Страница 14: ...lays indoor humidity in the third line When the indoor relative humidity rises above 70 WET appears indicating ex cess moisture in the air When the indoor relative humidity falls below 40 DRY appears...

Страница 15: ...tures and humidity 1 Press MEMORY to recall the maxi mum MAX indoor and outdoor tem peratures and indoor humidity display 2 Press MEMORY again to recall the minimum MIN indoor and outdoor temperatures...

Страница 16: ...imum maximum memory and reset it to the current temperature hold down MEMORY for about two seconds The display resets and the current temperatures and humidity appears RESETTING THE THERMOMETER If the...

Страница 17: ...p it Keep the thermometer away from dust and dirt and wipe it with a damp cloth occasional ly to keep it looking new Modifying or tampering with the ther mometer s internal components can cause a malf...

Страница 18: ...50 to 70 C Relative Humidity Operating Range 25 to 95 RH Temperature Compensation Range 14 to 140 F 10 to 60 C Resolution 0 2 F 0 1 C Sampling Cycle Approximate 10 Seconds Accuracy 1 8 at 32 to 104 F...

Страница 19: ...nsions HWD 59 16 35 16 15 16 Inches 142 84 24 mm Specifications are typical individual units might vary Specifications are subject to change and improvement without notice 63 1032 fm Page 19 Thursday...

Страница 20: ...warranty period take the product and the Ra dioShack sales receipt as proof of purchase date to any RadioShack store RadioShack will at its option unless otherwise provided by law a correct the defect...

Отзывы: