Radio Shack 2200087 Скачать руководство пользователя страница 26

2

=

©

c

=

re

5

T

<<

Limited

Warranty

RadioShack

warrants this product against defects

in

materials

and

workmanship

under normal use

by

the

original purchaser

for

ninety

(90)

days after

the

date

of purchase

from

a

RadioShack-owned store or

an

authorized

RadioShack

franchisee or

dealer. RADIOSHACK

MAKES

NO OTHER EXPRESS

WARRANTIES.

This

warranty

does

not

cover:

(a)

damage

or

failure

caused

by

or

attributable

to

abuse, misuse,

failure

to

follow

instructions,

improper

installation

or maintenance.

alteration, accident. Acts of

God

(such as floods or

lightning),

or excess voltage

or

current;

(b)

improper

or

incorrectly

performed

repairs

by

persons

who

are

not

a RadioShack

Authorized

Service

Facility; (c)

consumables such as fuses or

batteries;

(d)

ordinary

wear and tear or cosmetic damage;

(e)

transportation,

shipping

or insurance costs;

(f)

costs of product

removal,

installation,

set-up

service, adjustment

or

reinstallation;

and

(g)

claims

by

persons other than

the

original

purchaser.

Should

a

problem

occur

that

is

covered

by

this

warranty,

take

the

product and

the

RadioShack

sales

receipt as proof of purchase date

to

any RadioShack

store

in

the

U.S.

RadioShack

will,

at

its

option, unless otherwise

provided

by

law:

(a)

repair

the

product without charge

for

parts

and

labor:

(b)

replace

the

product

with

the

same or

a

comparable

product;

or

(c)

refund

the

purchase

price.

All

replaced parts

and

products,

and

products on

which a refund

is

made, become

the

property

of

RadioShack. New

or reconditioned parts

and

products

may

be used

in

the

performance of warranty

service. Repaired

or

replaced

parts and products are

warranted

for

the

remainder

of

the

original

warranty

period.

You

will

be charged

for

repair

or

replacement

of

the

product made after

the

expiration

of

the

warranty

period.

RADIOSHACK

EXPRESSLY

DISCLAIMS

ALL

WARRANTIES AND CONDITIONS

NOT

STATED

IN

THIS

LIMITED WARRANTY. ANY IMPLIED

WARRANTIES

THAT

MAY

BE

IMPOSED

BY

LAW, INCLUDING

THE

IMPLIED WARRANTY

OF

MERCHANTABILITY AND,

IF

APPLICABLE, THE

IMPLIED WARRANTY

OF

FITNESS

FOR

A

PARTICULAR

PURPOSE, SHALL

EXPIRE

ON THE

EXPIRATION

OF THE

STATED WARRANTY

PERIOD.

EXCEPT

AS

DESCRIBED

ABOVE,

RADIOSHACK SHALL

HAVE

NO

LIABILITY

OR RESPONSIBILITY TO THE PURCHASER OF THE PRODUCT OR

ANY

OTHER PERSON OR

ENTITY WITH

RESPECT TO

ANY LIABILITY,

LOSS OR

DAMAGE

CAUSED

DIRECTLY

OR

INDIRECTLY

BY

USE OR PERFORMANCE

OF THE PRODUCT OR

ARISING

OUT OF

ANY BREACH

OF THIS

WARRANTY,

INCLUDING,

BUT

NOT

LIMITED TO, ANY

DAMAGES

RESULTING

FROM

INCONVENIENCE AND

ANY

LOSS OF

TIME, DATA, PROPERTY, REVENUE,

OR

PROFIT AND

ANY INDIRECT,

SPECIAL,

INCIDENTAL,

OR CONSEQUENTIAL

DAMAGES, EVEN

IF

RADIOSHACK

HAS BEEN

ADVISED OF THE

POSSIBILITY

OF SUCH

DAMAGES.

26

Содержание 2200087

Страница 1: ...ote The supplied USB cable with ferrite must be used with your multimeter to ensure compliance with the Class B FCC limits Section 15 27 Ce We hope you enjoy your True RMS Digital Multimeter from Radi...

Страница 2: ...Capacitanc Checking Continuity Checking Diodes Measuring Logic Measuring Frequency Duty Cycle Pulse Width Measuring AC Voltage AC Current Frequency Measuring heg Advanced Operation System Requirement...

Страница 3: ...aA 2 inside meter Features Measures voltage current resistance capacitance frequency temperature and more True RMS for more accurate AC voltage and current readings Auto ranging with manual ranging ov...

Страница 4: ...You can order replacement leads from your local RadioShack store Donotuseafuse of brand or rating other than those specified here Doing so might damage your meter Because many AC DC sets have a potent...

Страница 5: ...ON CATEGORY II 3600VA max 500V To avoid electrical shock or instrument damage do not MAX connect the common input terminal COM jack to any k source that exceeds 500 volts with respect to earth ground...

Страница 6: ...or bury them Ifyou do not plan to use the meter fora month or more remove the batteries Batteries can leak chemicals that can destroy electronicparts When Z3 appears or the meter stops operating prop...

Страница 7: ...an 400maA plug the red test lead into 10A MAX instead of V mA Q AN WARNING Although the test leads are rated for 1000 volts and the maximum rating of this meteris 1000 volts DC 750 volts RMS AC do not...

Страница 8: ...res current Qrit Measures ohms and capacitance o Pk Checks continuity and diodes Hz LOGIC Measures logic HI LO frequency hee Measures the gain of small signal bipolar transistors OFF Switches offthe m...

Страница 9: ...Selects auto or manual ranging Selects different ranges in manual range mode RELA Takes relative measurements Hz DUTY WIDTH Measures frequency duty cycle and pulse width MAX MIN Stores maximum and min...

Страница 10: ...r off function turn the meter off then back on Select a Function and Range Each position on the function dial accesses one or more individual functions To select a function 1 Turn the function dial to...

Страница 11: ...pe OR dddd pA dd dd mA ddd d mA dddd A dddd A ddd dQ d ddd kQ dd dd kQ Set the meter to any function except C F dBm TF LOGIC or hgg Connect the test leads tothe circuit Press RANGE to select a suitab...

Страница 12: ...ing To manually set the range press RANGE NUI disappears Press RANGE again to change the range if necessary 3 Power offthe circuit under test Touch the test leads to the circuit Or to measure AC volta...

Страница 13: ...selected range Move the red test lead to V mA Q Rotate the function dial to pA A or mA A depending on the value you measured in Step 6 Reapply power to the circuit t 1 Note Ifyou are measuring DC curr...

Страница 14: ...ve one of the leads of the capacitor fromits circuit and connect the test leads to the capacitor s matching positive or negative terminals The measured value appears Note The voltages applied across e...

Страница 15: ...est leads to the component Note the first reading 5 Reverse the test leads and note the second reading If one reading shows a value and the other is overrange OF appears the device is good If OF appea...

Страница 16: ...V peak 1 Rotate the function dial to Hz LOGIC 2 Press SELECT until Hz KHz or MHz appears Otherwise press Hz DUTY WIDTH to select duty cycle function appears or pulse width function uS or mS appears 3...

Страница 17: ...pinout 1 2 Ifthe function dial is set to 2V dBm and you want to set the meter for maximum sensitivity when measuring a new signal press SELECT to select the AC V function then press Hz DUTY WIDTH to...

Страница 18: ...ware 1 Turn on your computer and start the installed Windows operating system 2 Use the supplied USB cable to connect the multimeter to your computer Note the sticker Connect to PC on the cable 3 Inse...

Страница 19: ...ter allows you to take relative measurements for certain functions This allows you to measure very low resistance or identify closely matching measurements This feature is not available for C F dBm 9...

Страница 20: ...ve relative value A reading of 0 00 indicates an exact match To stop relative measurement press RELA again or set the function dial to another setting Note Forthe most accurate reading the temperature...

Страница 21: ...and filed ceramic fuse are stored in the holders inside the cabinet near the top ofthe meter 1 Turn offthe meter and disconnect thetestleads 2 Loosen the three screws from the back cover and gently pu...

Страница 22: ...ng 3 in last digit B00V wooo 0 6 of reading 3 in last digit FEO ersssnsmsmmrey 0 8 of reading 4 in last digit DC CURRENT Maximum measurement 10A 600A 60mA 6A 6mA 400mA JOA creme 0 8 of reading 5 in la...

Страница 23: ...n last digit Sensitivity The function dial set to Hz LOGIC 10Hz 4MHz L00HzZ 1KFlz LOKHZ vuaamsnmimmmmmpssssesases rE 50mVrms 100mVrms For DC and AC voltage frequency the function dial set to V dBm max...

Страница 24: ...alue coo Overflow 6000 counts Range Down Detect Value 580 counts Low Battery Indication snBAN RO BY Sleep Mode CUMTeNt cero10 pA normal 20pA Max Input Impedance DCV ACV 10 megohmin parallel with 50pF...

Страница 25: ...the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to wh...

Страница 26: ...e for parts and labor b replace the product with the same or a comparable product or c refund the purchase price All replaced parts and products and products on which a refund is made become the prope...

Страница 27: ...ntial damages so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state You may contac...

Страница 28: ...istered trademarks of Microsoft Corporation in the United States and or other countries 2013 RadioShack Corporation Allrights reserved RadioShack is a registered Printed trademark used by RadioShack C...

Отзывы: