MASTER BKGRD 6-26-07
1
MASTER BKGRD 6-26-07
Specifications
K-TEMpERATURE MODE
This is a special �oltage mode, to be used with an optional thermocouple module that can
be attached to the meter. This mode automatically con�erts the 1mV per
°
C or
°
F �oltage
into a readout that appears as a temperature. �n these modes, the unit can show up to ±
999
°
C or
°
F.
The accuracy of these modes is determined by the e�ternal de�ice and the accuracy of the
DC �olt mode. The temperature range of the newer 1mV per degree C probes is generally
between –50
°
C and 1000
°
C.
FREQUENCY
Accuracy
400Hz, 4k, 40k, 400kHz, 4MHz:
...................................
± 0.1% of Reading, ± 4 in Last Digit
± 0.1% of Reading, ± 4 in Last Digit
Sensitivity
The function dial set to
LOGIC/Hz
(10Hz – 4MHz)
400Hz, 4k, 40kHz
.................................................................................................... 50 mVrms
400kHz
.................................................................................................................. 100 mVrms
4MHz
..................................................................................................................... 250 mVrms
For AC �oltage frequency, the function dial set to
°C/°F / V
(ma�imum measuring
fre�uency 1 kHz for signal above 40V)
10Hz to 1 kHz
.........................................................................................................
70 mVrms
1kHz to 10 kHz
..................................................................................................... 400 mVrms
For AC �oltage frequency, the function dial set to
dBm ~ V
(ma�imum measuring
fre�uency 1 kHz for signal above 40V)
10 Hz to 200 Hz
.................................................................................................... 300 mVrms
200 Hz to 1 kHz
......................................................................................................... 0.4 Vrms
1 kHz to 10 kHz
............................................................................................................ 4 Vrms
For AC current frequency
400µA/4mA ................................................................................
10 Hz to 30 kHz: 250µArms
40mA/400mA .............................................................................
10 Hz to 30 kHz: 25mArms
4A/10A ...........................................................................................
10 Hz to 10 kHz: 2.5Arms
DUTY CYCLE
(Fre�uency Range: 10 Hz to 100 kHz)
10% – 90% (at +5V/-0V S�uare wave)
...................................
± 2 digits/kHz, ± 2 in last digit
Note
: Duty cycle accuracy depends on input signal frequency.