background image

Cat. No. 22-506

OWNER’S MANUAL

Please read before using this equipment.

12-Volt • 10-Amp

Regulated Power Supply

22-506.fm  Page 1  Friday, August 6, 1999  12:55 PM

Содержание 22-506

Страница 1: ...Cat No 22 506 OWNER S MANUAL Please read before using this equipment 12 Volt 10 Amp Regulated Power Supply 22 506 fm Page 1 Friday August 6 1999 12 55 PM...

Страница 2: ...ou that important operating and main tenance instructions are included in the literature accompanying this product This power supply has been tested and found to comply with all ap plicable UL standar...

Страница 3: ...n check the operation of autosound systems before you in stall them in your vehicle or even power marine equipment such as pumps Your power supply s features include Regulated Output Voltage makes it...

Страница 4: ...power supply falls it could injure a person or cause serious damage to the power supply Do not overload power outlets or extension cords An overload can result in fire or electric shock Do not use an...

Страница 5: ...d be operated only from a standard AC outlet that provides 120V AC 60 Hz as indicated on the label If you are not sure of the type of power supplied to your home consult your local power company For a...

Страница 6: ...d where it will be stepped on tripped over or otherwise subjected to damage or stress b Disconnect the power supply by pulling the cord s plug rather than the cord If your power supply does not operat...

Страница 7: ...the device requiring power 2 Set the power supply s POWER switch to OFF 3 Turn the sleeves of the red and black binding output posts counterclockwise to expose the wire holes 4 Insert the device s pos...

Страница 8: ...local RadioShack store has a wide selection of banana plugs and hook clips that are convenient for making the con nections to the binding posts 5 Insert the device s negative wire usually black into t...

Страница 9: ...cap on the front of the power supply Note Close the socket s cap when you are not using the socket 4 Plug the device s DC power cord into the power supply s cigarette lighter socket 5 Connect the powe...

Страница 10: ...and confirm the AC outlet has power If the outlet has power set POWER to OFF reduce the load by using a device that does not require more than 13 8V DC then set POWER to ON Your power supply s overloa...

Страница 11: ...verload Protection Fuse 4A 250V Output Ripple 150 mV RMS GENERAL Design Linear Type Operating Temperature Range 32 68 F 0 30 C Output Terminal Two Binding Posts 10 Amp Dimensions HWD 4 3 4 7 3 16 10 1...

Страница 12: ...arranty does not cover transportation costs Nor does it cover a product subjected to misuse or accidental damage EXCEPT AS PROVIDED HEREIN RADIOSHACK MAKES NO EXPRESS WARRANTIES AND ANY IMPLIED WARRAN...

Отзывы: