6.

 

T

EST 

M

ESSAGES

 

 

The sensor can be triggered to send test messages by placing a magnet next to the side of the 
sensor. The location of the magnet is indicated by the triangular notch on the side of RBSx01 
and RBSx05 sensors. RBSx04 sensors do not have this capability. There is a small magnetic Hall 
effect sensor that will detect the presence of a magnet and send a message. This can be used for 
diagnostic purposes to ensure the sensor is within range and connected to the network. 

 

7.

 

M

ESSAGE 

P

ROTOCOL

 

 

This section defines the protocol and message definitions for the sensor.  

 

If the standard Radio Bridge console (console.radiobridge.com) is not used, refer to this section 
to decode the sensor data and configure the sensor through downlink messages. 

Radio Bridge provides a web-based console at console.radiobridge.com 
to configure and monitor sensors. Usage of this console is highly 
recommended for most customers rather than implementing the 
protocols defined in this section. 

 

 

 

7.1.

 

Common Messages 

 

There are common messages across all wireless sensors that are defined in the document 

“Common Sensor Messages” which is available on the Radio Bridge website. 

 

 

Common messages include basic error messages, tamper, supervisory, and downlink ack. It is 
important to refer to that document prior to decoding the messages defined in this section. 

Refer to the document “Common Sensor Messages” for definitions of all 

common messages. Common messages are not defined in this document.

 

 

 

 

Содержание RBS306-US10M-US

Страница 1: ...Wireless Ultrasonic Level Sensor User Guide VERSION 1 5 SEPTEMBER 2019...

Страница 2: ...TEST MESSAGES 6 7 MESSAGE PROTOCOL 6 7 1 Common Messages 6 7 2 Uplink Messages 7 7 3 Downlink Messages 8 7 3 1 Threshold Mode 8 7 3 2 Report on Change Mode 9 7 3 3 Hold Time 10 7 3 4 Periodic Reports...

Страница 3: ...sensor provides high accuracy ultrasonic proximity detection and ranging in air If the measured distance rises above or falls below the configured thresholds an alert is sent over the wireless networ...

Страница 4: ...cal drawings 1 3 July 2019 Replaced 5 meter product with 10 meter 1 4 August 2019 Added hold time feature mounting instructions and updated mechanical drawings 1 5 September 2019 Updated common sectio...

Страница 5: ...ust be mounted such that the required distances are within that range Distances outside of that range will result in incorrect measurements This includes distances that are too close less than 500mm a...

Страница 6: ...high voltage for the life of the battery and then experience a rapid drop near the end whereas an alkaline battery will experience a more gradual reduction in voltage over time Radio Bridge sensors ar...

Страница 7: ...the standard Radio Bridge console console radiobridge com is not used refer to this section to decode the sensor data and configure the sensor through downlink messages Radio Bridge provides a web bas...

Страница 8: ...evel Event Payload Definitions 1 Current distance in millimeters upper byte 0 9999 2 Current distance in millimeters lower byte The distance can range between 0 9999 millimeters so two bytes are neede...

Страница 9: ...Downlink Configuration Message 0x10 Byte Description 0 Mode 0x00 for Threshold or 0x01 for Report on Change 1 6 Defined by Mode See Mode sections The mode byte selects one of two modes threshold base...

Страница 10: ...load is defined in the following table Table 9 Downlink Configuration Message for Report on Change Mode Byte Description 0 0x01 Report on Change mode 1 Periodic reporting in 1 minute or 1 hour interva...

Страница 11: ...rasonic is set to 1000 1 meter and the distance measurements are bouncing between say 900 and 1100 every 1 second then there will be a lower threshold event every 2 seconds If a hold time of 10 second...

Страница 12: ...efined in 1 minute increments when the most significant bit is 1 as shown in the following table Table 11 Period Bye byte 1 from Downlink Configuration Message Bit 7 Bits 6 0 0 Period defined in hours...

Страница 13: ...DGE INC WIRELESS ULTRASONIC LEVEL SENSOR PAGE 12 OF 15 8 MECHANICAL DRAWINGS The mechanical drawings provided in this section are for the main body of the sensor All dimensions are inches unless other...

Страница 14: ...WIRELESS ULTRASONIC LEVEL SENSOR COPYRIGHT 2019 RADIO BRIDGE INC WIRELESS ULTRASONIC LEVEL SENSOR PAGE 13 OF 15...

Страница 15: ...nsors FCC ID 2APNUSFM10R2 LoRaWAN RBS301 RBS304 and RBS305 sensors FCC ID 2APNUCMABZ LoRaWAN RBS306 sensors This device contains FCC IAU792U13A16858 This device contains equipment certified under IC 1...

Страница 16: ...o Bridge provides this document as is without warranty of any kind expressed or implied including but not limited to the implied warranties of fitness or merchantability for a particular purpose Radio...

Отзывы: