Table 8 

Downlink 

Configuration 

Message for 

Threshold 

Mode 

 

 

 

The upper and lower distance thresholds are 

unsigned

 values with units of one 

millimeter. Note that if the configuration settings exceed the maximum ratings on the 
sensor, the sensor may not report an event.  

Periodic reporting and hold time are described in the sections below. 

 

7.3.2.

 

Report on Change Mode 

Report on Change mode is set when byte 0 of the payload is set to 0x01. The remainder 
of the payload is defined in the following table. 

 

Table 9 Downlink Configuration Message for Report on Change Mode 

Byte  Description 

0x01 (Report on Change mode) 

Periodic reporting in 1 minute or 1 hour intervals. Default is 0 (disabled) 

Hold time in 1 second or 1 minute intervals 

Distance increase in mm, upper byte 

Distance increase, lower byte 

Distance decrease in mm, upper byte 

Distance decrease in mm, lower byte 

 

If the distance increase or decrease are non-zero, then the sensor will send an alert any 
time the distance changes by the specified amount. For example, if the distance 
increase and decrease are set to 5mm, then an alert is sent every time the distance 

Upper distance threshold in mm, upper byte. Default 1,000mm 

Upper distance threshold in mm, lower byte 

Содержание RBS306-US10M-EU

Страница 1: ...Wireless Ultrasonic Level Sensor User Guide VERSION 1 5 SEPTEMBER 2019...

Страница 2: ...TEST MESSAGES 6 7 MESSAGE PROTOCOL 6 7 1 Common Messages 6 7 2 Uplink Messages 7 7 3 Downlink Messages 8 7 3 1 Threshold Mode 8 7 3 2 Report on Change Mode 9 7 3 3 Hold Time 10 7 3 4 Periodic Reports...

Страница 3: ...sensor provides high accuracy ultrasonic proximity detection and ranging in air If the measured distance rises above or falls below the configured thresholds an alert is sent over the wireless networ...

Страница 4: ...cal drawings 1 3 July 2019 Replaced 5 meter product with 10 meter 1 4 August 2019 Added hold time feature mounting instructions and updated mechanical drawings 1 5 September 2019 Updated common sectio...

Страница 5: ...ust be mounted such that the required distances are within that range Distances outside of that range will result in incorrect measurements This includes distances that are too close less than 500mm a...

Страница 6: ...high voltage for the life of the battery and then experience a rapid drop near the end whereas an alkaline battery will experience a more gradual reduction in voltage over time Radio Bridge sensors ar...

Страница 7: ...the standard Radio Bridge console console radiobridge com is not used refer to this section to decode the sensor data and configure the sensor through downlink messages Radio Bridge provides a web bas...

Страница 8: ...evel Event Payload Definitions 1 Current distance in millimeters upper byte 0 9999 2 Current distance in millimeters lower byte The distance can range between 0 9999 millimeters so two bytes are neede...

Страница 9: ...Downlink Configuration Message 0x10 Byte Description 0 Mode 0x00 for Threshold or 0x01 for Report on Change 1 6 Defined by Mode See Mode sections The mode byte selects one of two modes threshold base...

Страница 10: ...load is defined in the following table Table 9 Downlink Configuration Message for Report on Change Mode Byte Description 0 0x01 Report on Change mode 1 Periodic reporting in 1 minute or 1 hour interva...

Страница 11: ...rasonic is set to 1000 1 meter and the distance measurements are bouncing between say 900 and 1100 every 1 second then there will be a lower threshold event every 2 seconds If a hold time of 10 second...

Страница 12: ...efined in 1 minute increments when the most significant bit is 1 as shown in the following table Table 11 Period Bye byte 1 from Downlink Configuration Message Bit 7 Bits 6 0 0 Period defined in hours...

Страница 13: ...DGE INC WIRELESS ULTRASONIC LEVEL SENSOR PAGE 12 OF 15 8 MECHANICAL DRAWINGS The mechanical drawings provided in this section are for the main body of the sensor All dimensions are inches unless other...

Страница 14: ...WIRELESS ULTRASONIC LEVEL SENSOR COPYRIGHT 2019 RADIO BRIDGE INC WIRELESS ULTRASONIC LEVEL SENSOR PAGE 13 OF 15...

Страница 15: ...nsors FCC ID 2APNUSFM10R2 LoRaWAN RBS301 RBS304 and RBS305 sensors FCC ID 2APNUCMABZ LoRaWAN RBS306 sensors This device contains FCC IAU792U13A16858 This device contains equipment certified under IC 1...

Страница 16: ...o Bridge provides this document as is without warranty of any kind expressed or implied including but not limited to the implied warranties of fitness or merchantability for a particular purpose Radio...

Отзывы: