RW8300E-a-PR (USB) Designer’s Guide (RRD2Z50-20200130001)
10
RW8300E-a-PR (USB-Device) General Information
RW8300E-NL
WiFi Ratings @ 25° C
Parameter
Min
Typical
Max
Units
Operating Temperature RW8300E-NL
0
25
50
o
C
Relative Humidity (non-condensing)
5
95
%
USB Voltage Requirement
4.5
5
5.5
VDC
Current consumption when WiFi_ON
340
mA
Current consumption when WiFi_OFF and
LAN connected
NO LAN
mA
Current consumption when WiFi_OFF and
LAN disconnected
170
mA
Storage and transportation condition. in
range of °C and % R.H.
Storage temperature: 0~+70
o
C
Humidity: <10% RH
Operating temperature and humidity
Operating temperature: 0~+50
o
C
Humidity: <95% RH
IP classification protection against harmful
ingress of water and particulate matter.
Ingress Protection Rating 21
RW8300E
WiFi Ratings @ 25° C
Parameter
Min
Typical
Max
Units
Operating Temperature RW8300E
0
25
50
o
C
Relative Humidity (non-condensing)
5
95
%
USB Voltage Requirement
4.5
5
5.5
VDC
Current consumption when WiFi_ON
370
mA
Current consumption when WiFi_OFF and
LAN connected
200
mA
Current consumption when WiFi_OFF and
LAN disconnected
170
mA
Storage and transportation condition. in
range of °C and % R.H.
Storage temperature: 0~+70
o
C
Humidity: <10% RH
Operating temperature and humidity
Operating temperature: 0~+50
o
C
Humidity: <95% RH
IP classification protection against harmful
ingress of water and particulate matter.
Ingress Protection Rating 21