Warranty

LIMITED WARRANTY

WARRANTOR:  S.E. International, Inc., P.O. Box 39, 436 Farm Road, Summertown, TN 38483-0039, USA, (931) 964-

3561

ELEMENTS OF WARRANTY:  S.E. International, Inc., warrants for 90 days the Geiger-Mueller tube and for one year all

materials and craftsmanship in this product to be free from all defects with only the limitations set out below.

WARRANTY DURATION:  The warranty shall terminate and be of no further effect one year (90 days on the GM tube)

after the original date of purchase of the product or at the time the product is: a) damaged or not maintained as is

reasonable or necessary, b) modified, c) repaired by someone other than the warrantor for a defect or malfunction covered

by this Warranty, d) contaminated with radioactive materials, or e) used in a manner or purpose for which the instrument

was not intended or contrary to S.E. International, Inc.’s written instructions.  This warranty does not apply to any product

subjected to corrosive elements, misuse, abuse, or neglect.

STATEMENT OF REMEDY:  In the event that the product does not conform to the warranty at any time while this warranty

is effective, the Warrantor will repair the defect and return the instrument to you prepaid, without charge for parts or labor.

NOTE:  While the product will be remedied under this warranty without charge, this warranty does not cover or provide for

the reimbursement or payment of incidental or consequential damages arising from the use of or the inability to use this

product.  The liability of the company arising out of the supplying of this instrument, or its use, whether on warranties or

otherwise, shall not in any case exceed the cost of correcting defects in the instrument, and after the said one year (90

days on the tube) period all such liability shall terminate.  Any implied warranty is limited to the duration of the written

warranty.

PROCEDURE FOR OBTAINING PERFORMANCE OF WARRANTY:  In the event that the product does not conform to

this warranty, please write or call to the address above.  S.E. International, Inc. will not accept contaminated instruments

for calibration or repair under warranty or otherwise.

NOTE:  Before using this instrument, the user must determine the suitability of the product for his or her intended use.

The user assumes all risk and liability connected with such use.

Содержание Inspector+

Страница 1: ...User Manual...

Страница 2: ...lity Menu 7 Options 8 4 Common Procedures 8 Establishing the Background Count 8 Environmental Area Monitoring 8 Checking for Surface Contamination 8 5 Maintenance 9 Calibration 9 Calibrating Using a S...

Страница 3: ...spector in temperatures over 100 F 38 C or in direct sunlight for extended periods of time Do not get the Inspector wet Water can damage the circuitry and the mica surface of the Geiger tube Do not pu...

Страница 4: ...nel Each switch has three settings which are described below Mode Switch Figure 1 2 mR hr Sv hr The numeric display shows the current radiation level in milliroentgens per hour or when SI units are us...

Страница 5: ...et through the plastic case to penetrate the mica surface of the tube The small radiation symbol Figure 1 7 on the front label indicates the center of the Geiger tube External For Inspector EXP only T...

Страница 6: ...ility Menu detailed in Chapter 3 Refer to the following table After 30 second start up the reading will be based if instrument is detecting on an average of the previous 100 CPS 30 seconds 6000 CPM or...

Страница 7: ...e Using Dose Rate Modes While Timer is On Dose rate modes can be used while the timer is on In any dose rate mode the hour glass indicator will continue to flash during a timed period At the end of th...

Страница 8: ...e information on using the timer see Taking a Timed Count in Chapter 3 A ten minute average is moderately accurate You can repeat it several times and see how close the averages are To establish a mor...

Страница 9: ...nt down timer sound 11 Turn off the Inspector Hold down the button on the end panel and turn on the Inspector The display shows CAL and the Inspector counts down for 15 seconds chirping each second Th...

Страница 10: ...L and the hourglass icon flashing At the end of the 30 seconds it beeps The display shows CAL and SET is flashing 7 Press the and buttons to adjust the reading to what it should be When the reading is...

Страница 11: ...ta radiation A beta particle consists of an electron emitted from an atom It has more mass and less energy than a gamma ray so it doesn t penetrate matter as deeply as gamma and X rays Alpha radiation...

Страница 12: ...r 3 Operation Autoranging Display update CAL Factor Range 001 to 199 Timer Can set 1 10 minute sampling periods in one minute increments 10 50 minute sampling periods in 10 minute increments and 1 24...

Страница 13: ...or carrying the instrument Appendix C Inspector EXP Carrying Case The reinforced protective probe cover prevents damage to the fragile window of the detector The front flap lifts out of the way to gai...

Страница 14: ...m Observer Software The Observer software runs on a Windows platform and can be used with the Inspector Digilert 50 and Geiger Radiation Monitors As an option any of our Radiation Alert instruments ca...

Страница 15: ...onform to the warranty at any time while this warranty is effective the Warrantor will repair the defect and return the instrument to you prepaid without charge for parts or labor NOTE While the produ...

Страница 16: ...e company serial no Inside battery compartment or rear label address City state zip code 4 calibrations per year circle 1 2 3 4 phone number date placed in service Mail to Attn Robert Russell S E Inte...

Отзывы: