37
SFK 34 - RAD - ING - Manuale - 1807.1_V3_firm.L225A
2 Ta
b
e
lla
pa
ra
m
e
tr
i_
M
IA
H
4
0
4
_
fir
m
.L
22
5A
_
S
F
K
_
E
N
2. FIRST START-UP
SUPPOR
T
C
ENTRE
PARAMETER
DESCRIPTION
RANGE
FUNCTION
P11
EXECUTION PERIOD OF THE OVERHEATING
FUNCTION
THROUGH THIS PARAMETER YOU CAN
ENABLE AND SET THE DURATION
OF THE EXECUTION PERIOD OF THE
OVERHEATING FUNCTION, DURING WHICH
THE CIRCULATING PUMP ACTIVATES BY
DISSIPATING THE HEAT IN EXCESS.
0
-
60
VALUE EXPRESSED IN SECONDS (PRE-SET AT 10
SECONDS)
P12
ACTIVATION PERIOD OF THE OVERHEATING
FUNCTION
THROUGH THIS PARAMETER YOU CAN SET
THE TIME INTERVAL FROM THE END OF THE
POST-CIRCULATION TO THE ACTIVATION
OF THE OVERHEATING FUNCTION.
0 - 20
VALUE EXPRESSED IN MINUTES (PRE-SET AT 10
MINUTES)
P13
MAXIMUM DOMESTIC SETPOINT
THROUGH THIS PARAMETER YOU CAN
SET THE USER-ADJUSTABLE MAXIMUM
DOMESTIC TEMPERATURE.
50 - 67
VALUE EXPRESSED IN °C (PRE-SET AT 60°C)
P14
MINIMUM DOMESTIC SETPOINT
THROUGH THIS PARAMETER YOU CAN
SET THE USER-ADJUSTABLE MINIMUM
DOMESTIC TEMPERATURE.
35 - 45
VALUE EXPRESSED IN °C (PRE-SET AT 40°C)
P15
ANTI-LEGIONELLA FUNCTION
(FOR STORAGE TANK)
THROUGH THIS PARAMETER YOU
CAN ACTIVATE/DEACTIVATE THE
“ANTILEGIONELLA” HEAT TREATMENT
OF THE STORAGE TANK. EVERY 7 DAYS
THE WATER TEMPERATURE INSIDE THE
STORAGE IS HEATED BEYOND 60 °C THUS
GENERATING A BURNING HAZARD. KEEP
UNDER CONTROL SUCH DOMESTICH
HOT WATER TREATMENT (AND INFORM
THE USERS) TO AVOID UNFORSEEABLE
DAMAGES TO PERSONS, ANIMALS AND
PROPERTY. A THERMOSTATIC VALVE
SHOULD BE INSTALLED AT THE DOMESTIC
HOT WATER OUTLET TO AVOID ANY BURNS.
0 - 1
0 = DISABLED
1 = ENABLED