background image

USER INSTRUCTIONS 

 

RK 55 - RAD - ING - MAN.UT – 1311.1 - DIGITECH CS MIAH4

 

6

 

 

Code 

E18  

Inadequate circulation

. ( 

 

associated symbol ). 

Call the Service Centre.

 

 

Code 

E21  

General malfunction inside the printed circuit board. 

 

associated symbol ). 

  Switch off the power supply at the main switch and then switch it on again; 

  When  the error code on the display disappears, the boiler will restart automatically. 

 If the problem persists, 

Call the Service Centre

 

Code 

E22  

Parameter programming request. 

 

associated symbol ). 

  Switch off the power supply at the main switch and then switch it on again; 

  When  the error code on the display disappears, the boiler will restart automatically. 

 If the problem persists, 

Call the Service Centre. 

 

Code 

E35  

Flame detection malfunction. 

(

 

associated symbol ). 

  Press Reset button 

’ on the control panel to reset the error; 

  When  the error code on the display disappears, the boiler will restart automatically. 

 If the problem persists, 

Call the Service Centre.

 

 

Code 

E40  

Electric power supply out of the operation range

. (

 

associated symbol ).

Call the Service Centre.

 

 

 

Function codes 

 

Code 

F08  

Frost protection function (central heating circuit) ON

Wait for the completion of the operation.

 

 
Code 

F09  

Frost protection function (D.H.W circuit) ON

(RS version only - with connection to a remote storage 

cylinder). Wait for the completion of the operation.

 

 

Code 

F28  

Legionella Prevention Function. (

RS version only - with connection to a remote storage cylinder).  

Wait for the completion of the operation.

 

 

Code 

F33  

System purging function ON. 

Wait for the completion of the operation.

 

Содержание RK 55

Страница 1: ...CE 0694 RK 55 RAD ING MAN UT 1311 1 DIGITECH CS MIAH4 Technical specification RADIANT BRUCIATORI S p A Montelabbate PU ITALY ENGLISH User Manual for model RK 55 Premix condensing system boiler...

Страница 2: ...Control Panel 2 3 Starting up the boiler 3 4 INFO Menu 3 5 Boiler functioning modes 4 6 Filling the system 5 7 Diagnostics Error and function codes 5 8 Switching OFF the boiler 6 9 Frost Protection 7...

Страница 3: ...uthorised technician do not attempt to start it All maintenance and gas conversion operations MUST BE CARRIED OUT BY PROFESSIONALLY QUALIFIED PERSONNEL Should any part of the boiler freeze up do not a...

Страница 4: ...AL WIRING 7 LCD DISPLAY LCD display icons key 1 PARAMETER NUMBER INFORMATION 2 PARAMETERS PROGRAMMING MODE ON 3 SOLAR PCB CONNECTION INFORMATION SOLAR PANEL TEMPERATURE DISPLAY d6 4 SOLAR PUMP ON 5 ST...

Страница 5: ...list of available data Press the INFO button to exit the display mode The list of available display data is the following Parameter Icon Description d00 DHW sensor temperature RS version only with con...

Страница 6: ...ion to a remote storage cylinder To switch boiler operation to SUMMER WINTER mode press the MODE SELECTION button page 2 fig 1 pos 3 The boiler will work for both central heating D H W systems The SUM...

Страница 7: ...nel to reset the error When the error code on the display disappears the boiler will restart automatically If the problem persists Call the Service Centre Code E02 Safety Thermostat tripped associated...

Страница 8: ...ts Call the Service Centre Code E35 Flame detection malfunction associated symbol Press Reset button on the control panel to reset the error When the error code on the display disappears the boiler wi...

Страница 9: ...and special functions that provide the starting of the burner to heat all the interested parts when their temperature drops below the minimum preset values This function is enabled if the boiler is e...

Страница 10: ...THE COMPANY RESERVES THE RIGHT TO APPLY VARIATIONS WITHOUT PRIOR NOTIFICATION NEITHER WILL THE COMPANY BE HELD RESPONSIBLE FOR ANY INACCURACIES IN THIS HANDBOOK DERIVING FROM PRINTING OR TRANSLATION E...