![Radiant R2K 34 RAIN Скачать руководство пользователя страница 47](http://html2.mh-extra.com/html/radiant/r2k-34-rain/r2k-34-rain_installation-use-and-maintenance-manual_3261851047.webp)
47
R2K 34 RAIN - RAD - ING - Manuale - 1612.1_firm.L181E
2 D
a
ti te
cnici
_
R
2
K 3
4
R
A
IN
_
E
r
P
_
E
N
2. MAINTENANCE
SUPPOR
T
C
ENTRE
Technical parameters for boiler space heaters, boiler combination heaters and cogeneration
space heaters
Model
R2K 34 RAIN
Condensing boiler
[yes/no]
yes
Low-temperature (**) boiler:
[yes/no]
yes
B11 boiler
[yes/no]
no
Cogeneration space heater
[yes/no]
no
If yes, equipped with a supplementary heater
[yes/no]
no
Combination heater
[yes/no]
yes
Rated heat output Prated
kW
33
For boiler space heaters and boiler combination
heaters: Useful heat output
At rated heat output and high-temperature regime (*) P
4
kW
33.0
At 30 % of rated heat output and low-temperature regime (**)
P
1
kW
9.9
For cogeneration space heaters: Useful heat output
At rated heat output of cogeneration space heater with
supplementary heater disabled P
Sup0
kW
-
At rated heat output of cogeneration space heater with
supplementary heater enabled P
Sup100
kW
-
)RUFRJHQHUDWLRQVSDFHKHDWHUV(OHFWULFDOHI¿FLHQF\
At rated heat output of cogeneration space heater with
VXSSOHPHQWDU\KHDWHUGLVDEOHGȘ
el,Sup0
%
-
At rated heat output of cogeneration space heater with
VXSSOHPHQWDU\KHDWHUHQDEOHGȘ
el,Sup100
%
-
$X[LOLDU\HOHFWULFLW\FRQVXPSWLRQ
At full load elmax
kW
0.04
At part load elmin
kW
0.02
In standby mode PSB
kW
0.004
6HDVRQDOVSDFHKHDWLQJHQHUJ\HI¿FLHQF\Ș
s
%
93
6HDVRQDOVSDFHKHDWLQJHQHUJ\HI¿FLHQF\FODVV
A
For boiler space heaters and boiler combination heaters:
8VHIXOHI¿FLHQF\
$WUDWHGKHDWRXWSXWDQGKLJKWHPSHUDWXUHUHJLPHȘ
4
%
88.3
At 30 % of rated heat output and low-temperature regime
Ș
1
%
97.7
)RUFRJHQHUDWLRQVSDFHKHDWHUV8VHIXOHI¿FLHQF\
At rated heat output of cogeneration space heater with
VXSSOHPHQWDU\KHDWHUGLVDEOHGȘ
Sup0
%
-
At rated heat output of cogeneration space heater with
VXSSOHPHQWDU\KHDWHUHQDEOHGȘ
Sup100
%
-
6XSSOHPHQWDU\KHDWHU
Rated heat output Psup
kW
-
Type of energy input
-
Other items
Standby heat loss P
stby
kW
0.1
Ignition burner power consumption P
ign
kW
0.0