background image

R1KG 24 - RAD - ING - Manuale - 1806.1_SK.2

Installation, Use 
and Maintenance Manual 
for model

 0476

R1KG 24

Premix condensing system boiler

only heating

Содержание R1KG 24

Страница 1: ...R1KG 24 RAD ING Manuale 1806 1_SK 2 Installation Use and Maintenance Manual for model 0476 R1KG 24 Premix condensing system boiler only heating...

Страница 2: ...3 GAS CONNECTION 18 1 1 14 ELECTRICAL CONNECTION 18 1 1 15 POWER SUPPLY 19 1 1 16 OPTIONAL ELECTRICAL CONNECTIONS 20 1 1 17 FUME EXHAUST FITTINGS 22 1 1 18 INSTALLATION MODES 23 1 1 19 TYPES OF FUME E...

Страница 3: ...TRANSFORMATION 58 3 USER SECTION 59 3 1 USE 60 3 1 1 GENERAL USE WARNINGS 60 3 1 2 CONTROL PANEL 61 3 1 3 DISPLAY ICONS 62 3 1 4 INFO MENU DISPLAY DATA 63 3 1 5 START UP 64 3 1 6 OPERATING MODE 64 3...

Страница 4: ...ferentiated by thickness and size in accordance with their hierarchy The images contain important parts described in the text marked with numbers or letters See chap chapter name this entry indicates...

Страница 5: ...thout any obligation to third parties neither will the company be held responsible for any inaccuracies in this handbook deriving from printing or translation errors the material and intellectual owne...

Страница 6: ......

Страница 7: ...be performed only by qualified personnel having the appropriate technical training in the field for the installation and maintenance of components of civil and industrial domestic hot water productio...

Страница 8: ...performance The location must be properly vented through an air vent The air vent must be placed at floor level to prevent it from being obstructed protected by a grid that does not hamper the useful...

Страница 9: ...electrical resistances kit see chapter ANTI FREEZE PROTECTION WARNING The manufacturer will not be held responsible for damages caused by incorrect installation not in conformity with the over mention...

Страница 10: ...cking elements cardboard box woodencrate nails fasteners plasticbags expanded polystyrene etc must be kept out of the reach of children as they may be dangerous Therefore they should be dismantled sui...

Страница 11: ...nuale 1806 1_SK 2 1 Dimensioni_R1KG_EN 1 INSTALLATION INSTALLER 1 1 5 OVERALL DIMENSIONS 1 1 6 JIG 380 325 150 255 845 450 655 50456055 240 765 A R G F A R G F R HEATING RETURN 3 4 G GAS 3 4 F COLD 1...

Страница 12: ...ECHNICAL SPACES The appliance must be installed exclusively on a flat horizontal solid floor capable of supporting its weight In order to allow the access inside the boiler for maintenance operations...

Страница 13: ...TALLER 1 1 8 CIRCULATOR PREVALENCE FLOW DIAGRAM Appliance Loss Wilo Yonos PARA MSL 12 6B 0 0 4 0 8 1 2 1 6 2 0 2 4 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 2 4 6 8 0 1 2 3 4 5 6 7 8 0 10 20 30 40 50 70 60 80 0...

Страница 14: ...operations from any off axis positioning that may damage the tubes causing leaks malfunction or early wear WARNING In order to avoid any vibrations and noises do not use tubes with small diameters or...

Страница 15: ...wering up the boiler fill the system as follows 1 slightly loosen the cap of the circulator jolly valve 1 fig 1 to release the air from the system 2 slightly loosen the cap of the jolly valve placed o...

Страница 16: ...r which corresponds to the middle part of the green zone ZV fig 4 1 1 11 FILLING THE CONDENSATE COLLECTION SIPHON Before starting the boiler you have to fill the condensate collection siphon in order...

Страница 17: ...heating flow water temperature reaches the 30 C and in presence of a return sensor until the heating return water temperature reaches the 20 C The system starts even if on the display appears OFF as l...

Страница 18: ...te 1 1 14 ELECTRICAL CONNECTION DANGER The equipment is electrically safe only if it is properly connected to an efficient grounding system performed in compliance with the safety standards in force Y...

Страница 19: ...boiler s front casing refer to chapter ACCESSING THE BOILER loosen the two screws and remove the plate A see fig 1 after removing the plate connect the electrical cables to terminal B see fig 1 the ye...

Страница 20: ...e fig 1 For the external temperature Probe connect the two non polarized conductors to the Se Se contacts For the environment Thermostat or Remote control first remove the bridge on the Ta Ta contacts...

Страница 21: ...e crankcase connect the items below to the electronic board see fig 1 After performing these operations remount the crankcase and the front casing TP CT BUS 0 10V GND BUS 11 10 9 8 7 12 13 14 15 16 17...

Страница 22: ...to favour the reflux of the condensate towards the combustion chamber suitably realized to collect and drain acid condensate For all air suction ducts with regard to the air path you should provide an...

Страница 23: ...ificated separately C83 Discharge in single or common fume exhaust duct and wall suction system C93 Discharge through an intubated conduct to a vertical terminal The technical compartment in which is...

Страница 24: ...length a section equal to or greater then that of the connection of the device discharge tube have no shut off devices shutters for direct external discharge there must be no more than two changes in...

Страница 25: ...combustion through co axial ducts the external one for air intake the plastic internal one for fumes discharge PLEASE SEE THE MAXIMUM DISCHARGE LENGTH IN THE TABLE IN CHAPTER TECHNICAL DATA The maximu...

Страница 26: ...ing fuel gas and air suctioning for combustion through two separated ducts PLEASE SEE THE MAXIMUM DISCHARGE AND INTAKE LENGTH IN THE TABLE IN CHAPTER TECHNICAL DATA The maximum discharge and intake le...

Страница 27: ...co axial ducts the external one for air intake the plastic internal one for fumes discharge PLEASE SEE THE MAXIMUM DISCHARGE LENGTH IN THE TABLE IN CHAPTER TECHNICAL DATA The maximum discharge length...

Страница 28: ......

Страница 29: ...s described below relative to first start up maintenance and replacement should be performed only by qualified personnel and authorized by RADIANT BRUCIATORI S p A 1 SUPPORT CENTRE SECTION 2 SUPPORT C...

Страница 30: ...ke sure that the grounding system works properly make sure that the combustion air adduction and fumes and condensate discharge take place properly in compliance with the Local and National Laws and S...

Страница 31: ...circulating pump automatic reset again further 3 minutes and switch off the power supply and switch it on again Open the gas tap Use the button to select the desired operation mode If the symbol is di...

Страница 32: ...the screw 2 fig 2 of the Off Set adjuster To increase the CO2 value turn the screw clockwise and vice versa if you want to decrease it Once completed the adjustment tighten the protection screw A fig...

Страница 33: ...ING THE PARAMETERS To access the parameters menu and adjust their values follow the procedure below 1 Press the button to select the OFF mode displayed using the symbol 2 Hold at the same time the key...

Страница 34: ...T CENTRE 4 Use the keys and of the symbol S to change the value of the parameter 5 Press the key to confirm the action and wait for the display to stop blinking indication of the fact that the adjustm...

Страница 35: ...LER MODEL SELECTION 0 10 0 13 KW 1 18 KW HEAT 24 KW DOMESTIC 2 25 KW 3 28 KW 4 34 KW 5 55 KW 6 100 KW 7 R1K 18_24 R2K 24 R2KA 24 IN ALL VERSIONS 8 R1K 25_28 R2K 28 R2KA 28 IN ALL VERSIONS 9 R1K 34 R2K...

Страница 36: ...ET THE TIME DURING START UP PHASE NECESSARY FOR THE BOILER TO REACH THE MAXIMUM SET POWER ON THE HEATING SIDE 0 4 0 DISABLED 1 50 SECONDS SET BY DEFAULT 2 100 SECONDS 3 200 SECONDS 4 400 SECONDS P05 A...

Страница 37: ...TO OPERATE IN DOMESTIC MODE THE VALUE IS PRE SET BASED ON THE SET POWER SEE PARAMETER P00 AND ON THE GAS TYPE SEE PARAMETER P02 45 VALUE SET FOR PARAMETER P11 THE VALUE IS EXPRESSED IN HERTZ 1HZ 30 RP...

Страница 38: ...STMENT THROUGH THIS PARAMETER YOU CAN SET THE FAN SPEED DURING START UP THE VALUE IS PRE SET BASED ON THE SET POWER SEE PARAMETER P00 AND ON THE GAS TYPE SEE PARAMETER P02 VALUE SET FOR PARAMETER P10...

Страница 39: ...5 C THE SYSTEM TYPE CAN BE SET FROM PARAMETER P03 0 30 SET BY DEFAULT AT 15 THE NUMBERING OF THE VALUE CORRESPONDS TO KD CURVES ON THE CHART SEE CHART BELOW P17 DISABLEMENT OF DOMESTIC HOT WATER LINE...

Страница 40: ...E IS EXPRESSED IN C P21 MAXIMUM DOMESTIC SETPOINT THROUGH THIS PARAMETER YOU CAN SET THE USER ADJUSTABLE MAXIMUM DOMESTIC TEMPERATURE 45 75 THE VALUE IS EXPRESSED IN C P22 SET POINT T DELIVERY RETURN...

Страница 41: ...UPPORT CENTRE PARAMETER DESCRIPTION RANGE FUNCTION P25 D H W STORAGE TANK TEMPERATURE SETPOINT FOR STORAGE BOILERS ONLY THROUGH THIS PARAMETER YOU CAN SET THE PRIORITY STARTING VALUE OF THE STORAGE TA...

Страница 42: ...4_EN 2 FIRST START UP SUPPORT CENTRE 2 1 6 ELECTRIC FAN FREQUENCY HEAT CAPACITY DIAGRAM GAS TYPE MINIMUM FREQUENCY MAXIMUM FREQUENCY G20 Hz 45 188 G30 Hz 45 177 G31 Hz 45 190 G30 G20 G31 0 2 4 6 8 10...

Страница 43: ...d proceed as indicated in section CO2 VALUE CHECK AND CALIBRATION remove and clean the burner from oxidation check the integrity and the position of the sealed chamber sealing gasket check the primary...

Страница 44: ...4 Fumes temperature at nominal heat capacity C 80 26 Fumes temperature at minimum heat capacity C 65 7 CO2 at nominal heat capacity G20 9 3 9 1 CO2 at minimum heat capacity G20 9 8 8 CO2 at nominal h...

Страница 45: ...x m 10 Max discharge length 80 125 Vert Co ax m 12 Max discharge length 50 50 Vert Split m 10 Max discharge length 60 60 Vert Split m 32 Max discharge length 80 80 Vert Split m 60 Max discharge length...

Страница 46: ...h supplementary heater enabled PCHP100 Sup100 kW RU FRJHQHUDWLRQ VSDFH KHDWHUV OHFWULFDO H FLHQF At rated heat output of cogeneration space heater with VXSSOHPHQWDU KHDWHU GLVDEOHG el CHP100 Sup0 At r...

Страница 47: ...KHDWLQJ HQHUJ H FLHQF wh Daily fuel consumption Qfuel kWh Annual fuel consumption AFC GJ Contact details Tel 39 0721 9079 1 fax 39 0721 9079299 e mail info radiant it http www radiant it Name and addr...

Страница 48: ...ER UNIT 4 DETECTION ELECTRODE 5 RETURN PROBE 6 ELECTRIC FAN 7 CONDENSATE COLLECTION SIPHON 8 EXPANSION TANK 9 MODULATING PUMP 10 AIR RELIEF VALVE 11 HEATING PROBE 12 SAFETY THERMOSTAT 13 AIR SUCTION T...

Страница 49: ...E 2 FUMES SAFETY THERMOFUSE 3 HEAT EXCHANGER 4 BURNER UNIT 5 ELECTRIC FAN 6 GAS VALVE 7 WATER PRESSURE SWITCH 8 SAFETY VALVE 3 bar 9 CONDENSATE COLLECTION SIPHON 10 CIRCULATOR 11 SYSTEM DRAINING TAP 1...

Страница 50: ...NT THERMOSTAT AR ORANGE VG GAS VALVE SR HEATING PROBE L LINE GI YELLOW TRA START UP TRANSFORMER EV ELECTRIC FAN N NEUTRAL BI WHITE SRI RETURN SENSOR NE BLACK GR GREY ma ce ma ce ma ce ma gi bi gr EV c...

Страница 51: ...er 1 fig 1 by pulling it vertically grab panel 2 fig 1 from the upper side and rotate it downwards To remove the panel completely first dismantle the electronic PCB front panel from the support bracke...

Страница 52: ...in switch Follow the procedure described at chapter ACCESSING THE BOILER and rotate panel 2 fig 1 Unscrew the four fixing screws see A fig 2 remove the carter upwards see B fig 2 To access the termina...

Страница 53: ...activate it turn off the main power supply switch wait for the boiler to cool down connect a flexible tube to the system emptying outlet and connect the other end of the tube to a suitable discharge...

Страница 54: ...ESET E01 FLAME BLOCK NO FLAME LIGHT UP MANUAL RESET PRESS THE RESET KEY GAS MISSING CHECK THE ADDUCTION NETWORK MASS OR BROKEN START UP ELECTRODE REPLACE IT GAS VALVE BROKEN REPLACE IT SLOW LIGHT UP T...

Страница 55: ...UFFICIENT WATER PRESSURE INSIDE THE SYSTEM LOWER THAN 0 3 BAR LOAD THE SYSTEM AUTOMATIC WATER PRESSURE SWITCH CABLE DISCONNECTED CHECK THE WIRING WATER PRESSURE SWITCH BROKEN REPLACE IT E05 HEATING PR...

Страница 56: ...RD MICRO PROCESSOR IF THE MODULATION BOARD DOES NOT RESET THE ERROR AUTOMATICALLY REPLACE IT AUTOMATIC E22 P A R A M E T E R S PROGRAMMING REQUEST MICRO PROCESSOR MEMORY LOSS PARAMETERS REPROGRAMMING...

Страница 57: ...CTIVATES AUTOMATICALLY WHEN THE HEATING PROBE DETECTS A TEMPERATURE OF 12 C THE BOILER OPERATES AT MINIMUM GAS PRESSURE WITH THE DIVERTER VALVE SET TO WINTER MODE IT DEACTIVATES WHEN THE HEATING FLOW...

Страница 58: ...3 and apply pressure on the rear side of venturi C fig 3 replace the body venturi with the one suitable for the type of supply gas cod 30 00124 for methane cod 30 00170 for GPL and make sure the tooth...

Страница 59: ...are addressed to all those who will use the machine The machine must be used and accessed only by qualified operators that fully read and understood the User section paying particular attention to th...

Страница 60: ...due to incorrect use DANGER The boiler should not be used by persons including children with reduced physical sensory or mental capacities or without suitable knowledge or experience unless they are...

Страница 61: ...S AND OTHER INFORMATION see chapter INFO MENU DISPLAY HOLD FOR 5 SECONDS IN OFF OPERATING MODE TO VIEW THE LAST 5 FAULTS 3 OPERATING MODE SELECTION KEY ONLY HEATING OFF 4 RESET KEY FAULTS RESET CHIMNE...

Страница 62: ...TEMPERATURE DISPLAY d7 6 EXTERNAL PROBE INSTALLED EXTERNAL PROBE TEMPERATURE d1 7 TEMPERATURE DISPLAY SET POINT PARAMETER VALUE 8 OPEN THERM COMMUNICATION PRESENT REMOTE CONTROL AREA CONTROL UNIT 9 I...

Страница 63: ...displayed data To exit display mode press the INFO key LIST OF DISPLAYED DATA INFO CODE ICON DESCRIPTION d0 DOMESTIC CIRCUIT PROBE TEMPERATURE d1 EXTERNAL PROBE TEMPERATURE d2 FAN SPEED d3 BOTTOM ARE...

Страница 64: ...TEMPERATURE You can adjust the temperature using keys and of the heating circuit press key to decrease the temperature press key to increase the temperature The heating temperature adjustment field ra...

Страница 65: ...IONAL NOTE ON ANTI FREEZE FUNCTION The boiler is protected against freezing thanks to the electronic board preparation with functions that start the burner and heat the concerned parts when their temp...

Страница 66: ...essure reaches 1 2 bar which corresponds to the middle part of the green zone ZV fig 2 After performing this operation make sure that the loading tap R fig 1 is properly closed After the water pressur...

Страница 67: ...PPORT CENTRE E02 SAFETY THERMOSTAT 95 C CONTACT THE TECHNICAL SUPPORT CENTRE E03 FUMES SAFETY THERMOFUSE 102 C CONTACT THE TECHNICAL SUPPORT CENTRE E04 WATER MISSING IN THE SYSTEM IF THE SYSTEM PRESSU...

Страница 68: ...THE MAIN SWITCH AND THEN RESTORE IT AS SOON AS THE ERROR CODE DISAPPEARS THE BOILER WILL RESTART AUTOMATICALLY IF THE BLOCK PERSISTS CONTACT THE TECHNICAL SUPPORT CENTRE E35 RESIDUAL FLAME PRESS THE R...

Страница 69: ...ttive_solo risc_MIAH4_EN 3 USE USER 3 1 10 ACTIVE FUNCTIONS SIGNALLING CODES CODE FUNCTION INTERVENTION F08 H E A T I N G A N T I F R E E Z E FUNCTION ACTIVE WAIT UNTIL THE OPERATION IS COMPLETED F33...

Страница 70: ...device using a wet cloth and come neutral soap WARNING DONOTuseabrasiveorpowderdetergents as they might damage the plastic cover and control elements 3 1 13 DISPOSAL The boiler and all its accessories...

Страница 71: ......

Страница 72: ...RADIANT BRUCIATORI s p a Via Pantanelli 164 166 61025 Loc Montelabbate PU Tel 39 0721 9079 1 fax 39 0721 9079279 e mail info radiant Internet http www radiant it...

Отзывы: