Radiant R1K 75 Скачать руководство пользователя страница 5

5

R1K 75 - RAD - ING - Man.Ut. - 1901.1_con_PA_AHS

3 A

v

v

ertenze gener

ali per l'utilizzo_EN

3.    USE

USER

1.1. USE

1.1.1. GENERAL USE WARNINGS

 WARNING

Before starting the boiler the User must 

make sure that the First start-up certificate has the 
stamp of the technical Support Centre proving the 
testing and the first start-up of the boiler.

 WARNING

To validate the warranty, the boiler must 

be started by a technical Support Centre authorized 
by RADIANT no later than 30 days from the date of 
installation.

 WARNING

In order to take advantage of the guarantee 

provided by the manufacturer, the customer should 
carefully and exclusively observe the instructions 
given in the USER section of the manual.

 ATTENTION

This machine may be used only for the 

purpose for which it has been designed: heat water 
to a temperature below boiling point at atmospheric 
pressure. Any other use is considered wrong and 
dangerous. The manufacturer is excluded from 
any contractual or out of contract responsibility for 
damage caused to people, animals or property due to 
incorrect use.

 DANGER

The boiler should not be used by persons 

(including children) with reduced physical, sensory or 
mental capacities or without suitable knowledge or 
experience unless they are instructed on the device 
use or monitored by a person responsible for their 
safety.

 DANGER

DO NOT obstruct the air vents of the 

location in which the gas device is installed to prevent 
the formation of toxic explosive mixes.

 DANGER

If you sense a gas odour in the location in 

which the boiler is installed, proceed as follows:

 

› DO NOT use electrical switches, the telephone or 

any other device that might generate electrical 
discharges or sparks;

 

› Immediately open all doors and windows to 

create an air exchange that can quickly clean the 
location;

 

› Close the gas valves;

 

› Request immediate intervention of qualified 

staff.

 DANGER

The use of the electrical power boiler 

implies respecting some fundamental rules such as:

 

› DO NOT touch the device with wet and/or humid 

parts and/or with bare feet;

 

› DO NOT pull the electrical cables;

 

› DO NOT leave the device exposed to atmospheric 

agents (rain, sun, etc.) unless specifically 
intended;

 

› in case of cable damage, turn off the device and 

contact qualified professional staff to replace it.

Содержание R1K 75

Страница 1: ...R1K 75 RAD ING Man Ut 1901 1_con_PA_AHS Use Manual for model Premix condensing system boiler only heating R1K 75...

Страница 2: ..._EN Contact Details Office Address 10 Frankston Gardens Drive Carrum Downs Victoria Australia 3201 Email Address sales hydronicsupplies com au Website www hydronicsupplies com au Phone 61 3 9708 2600...

Страница 3: ...CONTENTS 1 1 USE 5 1 1 1 GENERAL USE WARNINGS 5 1 1 2 CONTROL PANEL 6 3 1 3 DISPLAY ICONS 7 3 1 4 INFO MENU DISPLAY DATA 8 3 1 5 START UP 9 3 1 6 OPERATING MODE 9 3 1 7 INFORMATIONAL NOTE ON ANTI FRE...

Страница 4: ...4 R1K 75 RAD ING Man Ut 1901 1_con_PA_AHS R1K 75_Man Ut _AHS_EN TABLE OF CONTENTS...

Страница 5: ...y due to incorrect use DANGER The boiler should not be used by persons including children with reduced physical sensory or mental capacities or without suitable knowledge or experience unless they are...

Страница 6: ...ES AND OTHER INFORMATION see chapter INFO MENU DISPLAY HOLD FOR 5 SECONDS IN OFF OPERATING MODE TO VIEW THE LAST 5 FAULTS 3 OPERATING MODE SELECTION KEY ONLY HEATING OFF 4 RESET KEY FAULTS RESET CHIMN...

Страница 7: ...ER TEMPERATURE DISPLAY d7 6 EXTERNAL PROBE INSTALLED EXTERNAL PROBE TEMPERATURE d1 7 TEMPERATURE DISPLAY SET POINT PARAMETER VALUE 8 OPEN THERM COMMUNICATION PRESENT REMOTE CONTROL AREA CONTROL UNIT 9...

Страница 8: ...f displayed data To exit display mode press the INFO key LIST OF DISPLAYED DATA INFO CODE ICON DESCRIPTION d00 DOMESTIC CIRCUIT PROBE TEMPERATURE ONLY FOR THE VERSION WITH REMOTE BOILER SUPPLY SYSTEM...

Страница 9: ...r meets only the demands of heating To switch the boiler to HEATING ONLY operating mode press the function key the symbol will appear fixed on the display indicating that the function is enabled Whene...

Страница 10: ...abled If the boiler was previously running it will be turned off and the post ventilation and post circulation functions will be enabled If you have to deactivate the boiler for a long period of time...

Страница 11: ...TRE E02 SAFETY THERMOSTAT 95 C CONTACT THE TECHNICAL SUPPORT CENTRE E03 FUMES SAFETY THERMOFUSE 102 C CONTACT THE TECHNICAL SUPPORT CENTRE E04 WATER MISSING IN THE SYSTEM IF THE SYSTEM PRESSURE IS BEL...

Страница 12: ...S CONTACT THE TECHNICAL SUPPORT CENTRE E31 SOLAR AUXILIARY BOARD CONNECTION FAULTS CONTACT THE TECHNICAL SUPPORT CENTRE E32 COMMUNICATION ERROR BETWEEN THE BOILER BOARD AND THE MODBUS BOARD CONTACT TH...

Страница 13: ...E USER 3 1 9 ACTIVE FUNCTIONS SIGNALLING CODES CODE FUNCTION INTERVENTION F08 HEATING ANTI FREEZE FUNCTION ACTIVE WAIT UNTIL THE OPERATION IS COMPLETED F09 DOMESTIC CIRCUIT A N T I F R E E Z E FUNCTIO...

Страница 14: ......

Страница 15: ......

Страница 16: ...RADIANT BRUCIATORI s p a Via Pantanelli 164 166 61025 Loc Montelabbate PU Tel 39 0721 9079 1 fax 39 0721 9079279 e mail info radiant Internet http www radiant it...

Отзывы: