R1K 34 - RAD - ING - Man.Ut. - 1901.1_firm.L224C_AHS

3 Ic

one del display_sol

o risc_MIAH4_EN

3.    USE

USER

1.1.3. DISPLAY ICONS

KEY

1.  INDICATION OF PARAMETER NUMBER OR 

DISPLAYED INFO CODE

2.  PARAMETERS PROGRAMMING FUNCTION 

ACTIVE

3.  SIGNALLING CONNECTED SOLAR BOARD / 

SOLAR COLLECTOR TEMPERATURE DISPLAY 
(d5)

4.  SOLAR PUMP ACTIVE

5.  BOILER LOWER TEMPERATURE DISPLAY (d6) 

/ BOILER UPPER TEMPERATURE DISPLAY (d7)

6.  EXTERNAL PROBE INSTALLED / EXTERNAL 

PROBE TEMPERATURE (d1)

7.  TEMPERATURE DISPLAY / SET POINT / 

PARAMETER VALUE

8.  OPEN THERM COMMUNICATION PRESENT 

(REMOTE CONTROL / AREA CONTROL UNIT)

9.  INSUFFICIENT SYSTEM WATER PRESSURE 

SIGNALLING

10. FLAME PRESENT SIGNALLING / IT ALSO 

INDICATES, ON 3 PERCENTAGE LEVELS, THE 
MODULATING POWER LEVEL OF THE BOILER 
(fig.2)

11.  ERROR DISPLAY THAT CAN BE RESET

12.  OFF OPERATING MODE

13.  ERROR DISPLAY THAT CAN NOT BE RESET

14.  OPERATION IN HEATING MODE ENABLED

4

5

6

7

9

10

11

12

13

14

1

2

3

8

≤ 

 33%

>

33%

<

66% 

>

66%

<

100% 

fig. 1

fig. 2

Содержание R1K 34

Страница 1: ...R1K 34 RAD ING Man Ut 1901 1_firm L224C_AHS Use Manual for model Premix condensing system boiler only heating R1K 34...

Страница 2: ..._EN Contact Details Office Address 10 Frankston Gardens Drive Carrum Downs Victoria Australia 3201 Email Address sales hydronicsupplies com au Website www hydronicsupplies com au Phone 61 3 9708 2600...

Страница 3: ...E WARNINGS 6 1 1 2 CONTROL PANEL 7 1 1 3 DISPLAY ICONS 8 1 1 4 INFO MENU DISPLAY DATA 9 1 1 5 START UP 10 1 1 6 OPERATING MODE 10 1 1 7 INFORMATIONAL NOTE ON ANTI FREEZE FUNCTION 11 1 1 8 SYSTEM FILLI...

Страница 4: ...4 R1K 34 RAD ING Man Ut 1901 1_firm L224C_AHS R1K 34_Man Ut _AHS_EN TABLE OF CONTENTS...

Страница 5: ...are addressed to all those who will use the machine The machine must be used and accessed only by qualified operators that fully read and understood the User section paying particular attention to th...

Страница 6: ...rty due to incorrect use DANGER The boiler should not be used by persons including children with reduced physical sensory or mental capacities or without suitable knowledge or experience unless they a...

Страница 7: ...URES AND OTHER INFORMATION see chapter INFO MENU DISPLAY HOLD FOR 5 SECONDS IN OFF OPERATING MODE TO VIEW THE LAST 5 FAULTS 3 OPERATING MODE SELECTION KEY ONLY HEATING OFF 4 RESET KEY FAULTS RESET CHI...

Страница 8: ...PER TEMPERATURE DISPLAY d7 6 EXTERNAL PROBE INSTALLED EXTERNAL PROBE TEMPERATURE d1 7 TEMPERATURE DISPLAY SET POINT PARAMETER VALUE 8 OPEN THERM COMMUNICATION PRESENT REMOTE CONTROL AREA CONTROL UNIT...

Страница 9: ...RETURN PROBE TEMPERATURE d5 SOLAR COLLECTOR TEMPERATURE IF SOLAR BOARD INSTALLED SCS d6 SOLAR BOILER TEMPERATURE BOTTOM IF SOLAR BOARD INSTALLED SBSI d7 SOLAR BOILER TEMPERATURE TOP IF SOLAR BOARD IN...

Страница 10: ...enabled Whenever heating energy is needed to heat the rooms the automatic start up system will start the burner this is indicated by displaying the symbol blinking WINTER MODE In this mode the boiler...

Страница 11: ...ctivate the boiler for a long period of time proceed as follows contact the Technical support centre that will empty the water system where no anti freeze is intended and will cut off the power water...

Страница 12: ...using pressure gauge M fig 1 that the system pressure reaches 1 2 bar see fig 2 After performing this operation make sure that the loading tap R fig 1 is properly closed After the water pressure reset...

Страница 13: ...AFETY THERMOSTAT 95 C CONTACT THE TECHNICAL SUPPORT CENTRE E03 FUMES SAFETY THERMOFUSE 102 C CONTACT THE TECHNICAL SUPPORT CENTRE E04 WATER MISSING IN THE SYSTEM IF THE SYSTEM PRESSURE IS BELOW 1 2 BA...

Страница 14: ...ONTACT THE TECHNICAL SUPPORT CENTRE E31 INCOMPATIBLE REMOTE CONTROL CONTACT THE TECHNICAL SUPPORT CENTRE E32 COMMUNICATION ERROR BETWEEN THE BOILER BOARD AND THE MODBUS BOARD CONTACT THE TECHNICAL SUP...

Страница 15: ...funzioni attive_solo risc_MIAH4_EN 3 USE USER 1 1 10 ACTIVE FUNCTIONS SIGNALLING CODES CODE FUNCTION INTERVENTION F08 HEATING ANTI FREEZE FUNCTION ACTIVE WAIT UNTIL THE OPERATION IS COMPLETED F33 SYS...

Страница 16: ...the device using a wet cloth and come neutral soap WARNING DONOTuseabrasiveorpowderdetergents as they might damage the plastic cover and control elements 1 1 13 DISPOSAL The boiler and all its accesso...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...RADIANT BRUCIATORI s p a Via Pantanelli 164 166 61025 Loc Montelabbate PU Tel 39 0721 9079 1 fax 39 0721 9079279 e mail info radiant Internet http www radiant it...

Отзывы: