2.2.8. TECHNICAL DATA

Model

R1K 18

CE certification

no.

0476CQ0134

Gas category

0

II2H3B/P

Discharge type

type

B2 3p-B 3 3-C13-C 3 3-C 4 3-
C53-C63-C83-C93

Energy efficiency 92/42 CEE

no. stars

4

Energy efficiency EN13203-1

no. stars

3

Maximum nominal heat capacity in heating circuit

kW

18

Minimum nominal heat capacity in heating circuit

kW

2.9

Useful thermal power - 60/80°C

kW

17.4

Minimum useful thermal power - 60/80°C

kW

-

Useful thermal power - 30/50°C

kW

18.99

Performance at 100% Pn - 60/80°C

%

96.4

Performance at 30% Pn - return 47°C

%

-

Performance at 30% Pn - return 30°C

%

107.5

Performance at 100% Pn - 30/50°C

%

105.5

Maximum combustion Performance

%

97.4

Fumes temperature at nominal heat capacity

°C

73.65

Fumes temperature at minimum heat capacity

°C

65.7

CO2 at nominal heat capacity - G20

%

9,3 - 9,1

CO2 at minimum heat capacity - G20

%

9 - 8,8

CO2 at nominal heat capacity - G30

%

11,4 - 11,2

CO2 at minimum heat capacity - G30

%

10,9 - 10,7

CO2 at nominal heat capacity - G31

%

10,5 - 10,3

CO2 at minimum heat capacity - G31

%

10,2 - 10

CO at nominal heat capacity

ppm

67

Fumes mass at nominal heat capacity

g/s

7.44

Fumes mass at minimum heat capacity

g/s

1.26

NOx class

class

6

Weighted Nox  (0% O2) mg/kWh

mg/kWh

35

Heating circuit

Adjustable heating temperature

°C

30-80 / 25-45

Maximum operating temperature for heating circuit

°C

80

Maximum operating pressure for heating circuit

bar

3

Minimum operating pressure for heating circuit

bar

0.3

Capacity of the system expansion vessel

litres

8

Dimensional characteristics

Width

mm

410

Depth

mm

307

Height

mm

642

Gross weight

Kg

35

Water connections

Flow

Ø

3/4”

Cold water

Ø

1/2”

Gas

Ø

3/4”

Содержание R1K 18

Страница 1: ...R1K 18 RAD ING Manuale 1706 1_V3 Installation Use and Maintenance Manual for model 0476 R1K 18 Premix condensing system boiler only heating...

Страница 2: ...s temperature at nominal heat capacity C 73 65 Fumes temperature at minimum heat capacity C 65 7 CO2 at nominal heat capacity G20 9 3 9 1 CO2 at minimum heat capacity G20 9 8 8 CO2 at nominal heat cap...

Страница 3: ...ax discharge length 80 125 Vert Co ax m 12 Max discharge length 50 50 Vert Split m 10 Max discharge length 60 60 Vert Split m 32 Max discharge length 80 80 Vert Split m 60 Max discharge length 50 Vert...

Страница 4: ...tary heater enabled PCHP100 Sup100 kW RU FRJHQHUDWLRQ VSDFH KHDWHUV OHFWULFDO HI FLHQF At rated heat output of cogeneration space heater with VXSSOHPHQWDU KHDWHU GLVDEOHG el CHP100 Sup0 At rated heat...

Страница 5: ...HQHUJ HI FLHQF wh Daily fuel consumption Qfuel kWh Annual fuel consumption AFC GJ Contact details Tel 39 0721 9079 1 fax 39 0721 9079299 e mail info radiant it http www radiant it Name and address of...

Страница 6: ...ELECTRODE 5 ELECTRIC FAN 6 AIR RELIEF VALVE 7 SAFETY VALVE 3 bar 8 MODULATING PUMP 9 GAS VALVE 10 SYSTEM DRAINING TAP 11 SAFETY THERMOSTAT 12 HEATING PROBE 13 LIGHT UP ELECTRODE 14 EXPANSION TANK 15...

Страница 7: ...FUMES SAFETY THERMOFUSE 2 HEAT EXCHANGER 3 BURNER UNIT 4 ELECTRIC FAN 5 GAS VALVE 6 AIR RELIEF VALVE 7 CIRCULATOR 8 SAFETY VALVE 3 bar 9 SYSTEM DRAINING TAP 10 HEATING PROBE 11 SAFETY THERMOSTAT 12 E...

Страница 8: ...AND OTHER INFORMATION see chapter INFO MENU DISPLAY HOLD FOR 5 SECONDS IN OFF OPERATING MODE TO VIEW THE LAST 5 FAULTS 3 OPERATING MODE SELECTION KEY ONLY HEATING OFF 4 RESET KEY FAULTS RESET CHIMNEY...

Страница 9: ...EMPERATURE DISPLAY d7 6 EXTERNAL PROBE INSTALLED EXTERNAL PROBE TEMPERATURE d1 7 TEMPERATURE DISPLAY SET POINT PARAMETER VALUE 8 OPEN THERM COMMUNICATION PRESENT REMOTE CONTROL AREA CONTROL UNIT 9 INS...

Страница 10: ...isplayed data To exit display mode press the INFO key LIST OF DISPLAYED DATA INFO CODE ICON DESCRIPTION d0 DOMESTIC CIRCUIT PROBE TEMPERATURE d1 EXTERNAL PROBE TEMPERATURE d2 FAN SPEED d3 BOTTOM AREA...

Страница 11: ...pressure gauge M fig 1 that the system pressure reaches 1 2 bar see fig 2 After performing this operation make sure that the loading tap R fig 1 is properly closed After the water pressure reset the b...

Страница 12: ...SET THE FAULT AS SOON AS THE ERROR CODE DISAPPEARS FROM THE DISPLAY THE BOILER WILL START AUTOMATICALLY IF THE BLOCK PERSISTS CONTACT THE TECHNICAL SUPPORT CENTRE E03 FUMES SAFETY THERMOFUSE 102 C CON...

Страница 13: ...E MAIN SWITCH AND THEN RESTORE IT AS SOON AS THE ERROR CODE DISAPPEARS THE BOILER WILL RESTART AUTOMATICALLY IF THE BLOCK PERSISTS CONTACT THE TECHNICAL SUPPORT CENTRE E35 RESIDUAL FLAME PRESS THE RES...

Отзывы: