3. This heater can be mounted in a horizontal or vertical manner, but  we recommend horizontal usage.  For wall mounting, 

there must be a 1.8m distance from your appliance to the ground. For ceiling mounting, there must be a 2.4m distance from 

your appliance to the ground. For both horizontal and vertical mounting on the wall, there must be a min. distance of 40cm 

between the appliance and the ceiling.The distance from your appliance from the corners should be min. 40cm for vertical 

use and min. 50cm for horizontal use.When installed to the ceiling, there must be a distance of 50cm between corners and 

the appliance.The distance from the front side of the heater to materials such as wood, cardboard, cloth etc., must be 

minimum at 1m. When mounting horizontally or to a ceiling, do not position the heater at an angle more than 90°and less than 

45°. 

4. The supply cable must be at the lower end of the heater if the heater is installed at an angle or vertically. Keep the supply 

cord away from the body of the heater which will get hot during use. 

5. Do not install the heater on a flammable surface. 

6. If the heater is to be used outside, a weatherproof outlet is recommended.

 

7. The heater must be installed on the mounting brackets provided. Fasten the brackets securely to the mounting surface and 

the backside of the heater using the nuts and screws supplied. The brackets can be used to adjust the direction of the heater, 

adjust the heater angle by loosening the two bolts on the wall mounting bracket, and tighten the bolts again when the desired 

angle is reached.

- 3 -

Radiance Infrared Outdoor Heater 2000W

Installation Manual

OUTDOOR HEATING

Wall and Ceiling Installation 
Please follow the instructions given on page 3

Stand Installation
Note:

 The heater with tip over function, with 45

º

 angle, once the heater extends over the angle

the heater will automatically stop working.

Отзывы: