the high temperature alarm setting mode, set the value as above. Press the [Set] button to finish alarm 

setting . 

3)  When the current temperature lower or higher the limited, the alarm sound active and LED flash. Press any 

key to silent, but the LED flash continue, until the temperature come back to the safe rang. 

 

When the alarm sound active 60 seconds continue, the sound will be silent 30 seconds and sound   

“bi

bi

 

 

Maximum temperature clear 

1)  Press[

▲] and [▼] buttons for 3 seconds to clear the maximum temperature. 

 

Code rematch 

1

 The transmitter has paired with the receiver before delivery. If you want to rematch the unit code, turn off 

the receiver at first, then press and hold [        ] button for 5 seconds to enter the code rematch mode. 

Sync

  icon display

   

2

 Turn off the transmitter at first

then press and hold [        ] button for 5 seconds to enter the code rematch 

mode

 

3

 The unit will be store the code automatically and then return to the normal working mode

 

 

ERROR SYMBOLS: 

Symbol 

Description 

Action required 

 

 

Transmitter low battery voltage 

Replace the battery with the same type   

 

 

Receiver low battery voltage 

Replace the battery with the same type   

LLL.L 

1) Sensor open circuit 
2) The reading is out of low range (-50

C/-58

F) 

1) Return the thermometer for repair 
2) Keep the measurement above low range 

HHH.H 

1) Sensor short circuit 
2) The reading is out of high range (70

C/158

F) 

1) Return the thermometer for repair 
2) Keep the measurement below high range 

Sync 

Code rematch 

 

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 

(1)  this device may not cause harmful interference, and (2) this device must accept any interference received, 

including interference that may cause undesired operation. 

This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled environment. 

This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator 

and your body. This device complies with Industry Canada Licence-exempt RSSs. Operation is subject to the 

following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any 

interference, including interference that m 

ay cause undesired operation of the device. Le présent appareil est 

conforme aux CNR d’Industrie Canada 

applicable aux appareils radio exempts 

de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) 

l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage 

radioélectrique subi, 

même si le brouillage est susceptible d’en compromettre le fonctionnement. 

Changes  or  Modifications  not  expressly  approved  by  the  party  responsible  could  void  the  user’s  authority  to 

operate this device. 

  

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 

15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a 

residential  installation.  This  equipment  generates,  uses  and  can  radiate  radio  frequency  energy  and,  if  not 

installed and used in accordance with the instructions, may cause harmful interference to radio communications. 

However, there is no guarantee that interference will not occur in a particular installation. 

If this equipment does cause harmful interference to radio or television reception, which can be determined by 

turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the 

following measures: 

-- Reorient or relocate the receiving antenna. 

Отзывы: