14
•
If the value is set to 0, it means that the timer is not set. The digital tube displays the ambient temperature
immediately if there is no operation in 5 seconds or any other button is pressed within 5 seconds.
•
(Digital tube) normal display: If the timer is not set, the digital tube always displays the current ambient tem-
perature, the unit “°C/°F” lights up, and the display range is (-9°C~40°C) (10°F~99 °F), (LO displays when the
temperatures is below -9°C/10°F, and HI displays when the temperatures is above 40°C/99°F). If the timer is
set, the ambient temperature is displayed for 5 seconds and then the remaining time is displayed for 5 seconds
alternately.
TIMER ON FUNCTION
•
Press the “TIME” button in the standby state to make the digital screen and the timer icon display the status;
the digital tube will turn on and off in 0.5 seconds. At this moment, the TIME button can be used to set the time
to 12H→11H→10H→9H→8H →7H→6H→5H→4H→3H→2H→1H→0H→12H→11H→10H→ ...; the step size
is 1 hour, and the prefix 0 is not displayed. When the TIME button is pressed for more than 3 seconds, the
schedule power-on is turned off.
•
If the schedule time is set to 0, it means that schedule power on is turned off, and the system will enter standby
state if there is no operation in 5 seconds. After schedule power-on is set, the digital tube will stop flashing and
start timing if there is button operation in 5 seconds or any button except the power button is pressed down. At
this moment, only the schedule time is displayed, and the ambient temperature isn’t displayed. Press the power
button during the schedule setting or timing, the system will start normally, run according to the current preset
function, and the schedule time will not be memorized.
•
The default working state turns on when the power is turned on for the first time.
•
Set schedule power on after normal shutdown (power isn’t turned off). At this moment, the working status is the
state before shutdown. For example, if the cooling mode is turned on when the power is turned off last time,
the cooling mode is also turned on when the power is turned on again. (Note: This timer set before the last
shutdown won’t be saved.)
•
When the timer/schedule button is pressed, the corresponding function indicator flashes (1HZ); for example, if
high speed and cooling function are set at the last shutdown, the timer/schedule indicator is always on and the
high speed ind cooling indicator flash. After the machine is turned on, the MCU starts to detect whether
there is water in the water tank when the pump has been running for 5S. If the software detects that the water
shortage protection switch is off (water shortage) for 5S, the water pump stops working; the buzzer beeps and
alarms 10S (software control).
•
When the schedule power on/off button is pressed, the function that will be turned on after power on will flash
at 1HZ, but the user can also switch to desired working status, e.g. switching from high speed to low speed
or cooling mode; the schedule power off can’t be saved or operated (the scheduled function flashes at 1HZ if
there is no button operation after 3S, or flashes immediately if any other button is pressed) The timing error is
within ±3%.
6.
COOLING/HUMIDIFYING
In the working state, press the “Cooling/humidifying” button to control the on/off of the pump. inside the machine.
When the cooling mode is turned on, the product starts to detect whether there is water in the water tank when the
pump has been running for 5S. If the unit detects that the water shortage protection switch is off (water shortage) for
5S, the water pump stops working; the buzzer beeps and alarms 10 times.
7.
VERTICAL SWING
In the working state, press the “Vertical swing” button to turn on the up-down swing.
8.
HORIZONTAL SWING
In the working state, press the “Horizontal swing” button to turn on the left-right swing.
SPEcIAL FUNcTIONS
POWER FAILURE MEMORY FUNCTION
•
In the power-on state, when the power is restored after power off, the device beeps 10 times (once per se-
cond), no display or operation; it restores the last power-on state after 30 seconds (all functions are restored,
including the new long-term work protection function).
•
If you press the power button during the recovery time, the last state is restored immediately.
•
Countdown of the timer function /delay start function also needs to remember. The error of each power failure
shouldn’t exceed 5 minutes (ignoring the power outage time).
•
The power-off memory function isn’t available when the power is turned on again after normal shutdown.