Radial Engineering SW8 Скачать руководство пользователя страница 9

True to the Music

Radial Engineering Ltd.

SW8 Owner’s Manual

7

OPERATION

Manual Mode

In this mode the SW8 may be toggled with the front panel INPUT SELECT switch or with an external latching footswitch connected 
to the CONTACT INPUT jack. If the SW8 does not toggle when either the front panel AB SELECT switch or external footswitch is 
depressed ensure the AUTO ON switch is in the outward position and its LED is not illuminated. 

Manual Mode with Alarm

In this mode the Tone Track signal is used to trigger an external alarm system in order to prompt the operator to manually switch to 
the backup machine. 

1. Record a Tone Track signal onto track-1 of your master multi-track.
2. Connect track-1 to either INPUT-A (channel-1) or the AUTO SWITCH input jack.
3. Ensure the AUTO ON switch is in the outward position and the LED is not illuminated.
4. Connect an appropriate alarm circuit to the CONTACT OUTPUT jack as described in the previous section.
5. While sending the Tone Track signal to the SW8, adjust the THRESHOLD control to fi nd the level where the front panel ALARM LED 

illuminates. Set the THRESHOLD control above this point.

6. Test the system by stopping playback on your master multi-track. When no Tone Track signal is fed to the SW8 the ALARM LED will 

illuminate and the CONTACT CLOSURE OUTPUT relay closes, triggering the external circuit alarm.

  

Automatic Mode

In this mode the Tone Track signal is used to trigger the SW8 to switch to INPUTS-B. To activate automatic switching, depress the 
AUTO ON switch and ensure the LED is illuminated. Auto switching works by sensing the Tone Track signal. A loss of Tone Track 
signal will cause the SW8 to toggle to INPUTS-B. 

1. Depress AUTO ON switch and ensure the LED is illuminated.
2. Record a Tone Track signal onto track-1 of your master multi-track.
3. Connect track-1 to either INPUT-A (channel-1) or the AUTO SWITCH input jack.
4. While sending the Tone Track signal to the SW8, adjust the THRESHOLD control to fi nd the level where the SW8 toggles to INPUT-

B. Set the THRESHOLD control above this point.

5. Test the system by stopping playback on your master multi-track. The SW8 should toggle to INPUTS-B.

Automatic Mode with Alarm

In this mode the Tone Track signal is used to toggle the SW8 and to trigger an alarm circuit connected to the CONTACT OUTPUT 
jack.

1. Depress AUTO ON switch and ensure the LED is illuminated.
2. Record a Tone Track signal onto track-1 of your master multi-track.
3. Connect track-1 to either the SW8 channel-1 or the AUTO SWITCH input.
4. Connect an appropriate alarm circuit to the CONTACT OUTPUT jack as described in the previous section.
5. While sending the Tone Track signal to the SW8, adjust the THRESHOLD control to fi nd the level where the SW8 toggles to INPUT-

B and the alarm is triggered. Set the THRESHOLD control a little above this point.

6. Test the system by stopping playback on your master multi-track. The SW8 should toggle to INPUTS-B and trigger the external 

alarm circuit.

TESTING THE SYSTEM 

Test the system before each performance. It is the sole responsibility of the user to determine if the system is 
performing as expected. Therefore it is very important to devise a testing procedure that takes into account the 
weakest links in the signal and control chains. Your test points should always be up-stream of those links in 
order to ensure every piece of equipment in the playback system is functioning properly. Due to the unlimited 
possibilities of how the SW8 can be used we can not take any responsibility for the use, applied application, 
miss-application or malfunction of the SW8 other than what is stated in the Radial warranty. If you are at all 
uncomfortable or feel the SW8 is not well suited to the task at hand please return the unit to your dealer. Please 
read the Radial warranty and performance disclaimer for details.

!

Содержание SW8

Страница 1: ...cifications and appearance are subject to change without notice Copyright 2007 Radial Engineering Ltd Radial Engineering Ltd 1638 Kebet Way Port Coquitlam BC V3C 5W9 tel 604 942 1001 fax 604 942 1010...

Страница 2: ...portant safety features along with tips on how to get the most out of your SW8 Should you have a questions on applications not covered in this manual we invite you to log onto the Radial web site at w...

Страница 3: ...channel snake system to the PA and FOH console The SW8 can operate in three modes manual automatic and remote Manual switching is accomplished using the front panel controls or an external latching fo...

Страница 4: ...ate items used to set up the automatic switching mode a AUTO ON Activates automatic switching mode Status LED indicates when Auto mode is active b AUTO SWITCH PHONE INPUT Dedicated input for Tone Trac...

Страница 5: ...8 13 1 2 3 Ground Male DB 25 Pin out Cable View 1 G G 2 3 G G 4 5 G G 6 7 G G 8 13 American standard SAE lock down screws Playback A Playback B Backup RADIAL 8 CHANNEL D SUB CABLE MOGAMI 8 CHANNEL D...

Страница 6: ...vel outputs allow the SW8 to interface with mic splitter snakes and console mic preamps If you hear distortion from the XLR outputs it is likely that the multi track output level is overloading the tr...

Страница 7: ...n the switch is depressed Remote Switching The FOOT SW phone jack on the rear panel allows the SW8 to be controlled with a remote contact closure system or latching footswitch Closing the circuit conn...

Страница 8: ...e CONTACT CLOSURE OUTPUT relay is in an open state preventing current from flowing through the external circuit When the SW8 detects a loss of Tone Track signal the front panel ALARM LED illuminates a...

Страница 9: ...ack 1 to either INPUT A channel 1 or the AUTO SWITCH input jack 4 While sending the Tone Track signal to the SW8 adjust the THRESHOLD control to find the level where the SW8 toggles to INPUT B Set the...

Страница 10: ...utput Type Passive balanced signal path Switching Time 3ms maximum 20 C XLR Output Frequency response 20Hz to 20kHz 2 5dB Total harmonic distortion 0 01 from 20Hz to 20kHz Output impedance 600 ohms Ou...

Страница 11: ...uts can be overloaded The GLOBAL PAD feature is provided to prevent transformer saturation Q Why doesn t the SW8 have an OFF ON switch A Because the SW8 features a passive signal path audio will alway...

Страница 12: ...t accompany any request for work to be performed under this limited warranty This limited warranty shall not apply if the product has been damaged due to abuse misuse misapplication accident or as a r...

Отзывы: