background image

Radial Engineering Ltd.

LX-3™  Line Splitter User Guide

4

MAkIng connEcTIonS

Before making connections, ensure that your sound system is turned off and all volume controls are turned down. This prevents 

any plug-in transients from damaging speakers or other sensitive components. The LX-3 is completely passive, so it doesn’t 

require any power to operate.   

The LX-3 has a combination XLR/TRS input connector, which is wired with the AES standard pin-1 ground, pin-2 hot (+), pin-3 

cold (-). You can connect balanced or unbalanced inputs to the LX-3. The isolated outputs will always be balanced signals, while 

the direct output can be balanced or unbalanced depending on the input source.  

ThE InpUT pAd

Should you have a particularly hot input signal that you are sending to the LX-3, you can engage a -12dB pad to knock down 

the signal and prevent distortion. This is done using the PAD switch, and will affect the output of the direct output LX-3, as well 

as both isolated XLR outputs. Should you wish to reduce the level at the isolated outputs, but keep the direct output at the level 

of the original signal, there is an internal jumper that you can adjust to accomplish this.

To change the operation of the PAD switch, so it 

doesn’t affect the direct output, follow these steps:

1. 

Use a hex key to remove the four screws that 

secure the cover of the LX-3.

2.  Slide the cover off the LX-3, and locate the in-

ternal jumper as indicated on the photo below.

3.  Move the jumper over to connect pins 2 and 3, 

this will allow the thru output to bypass the PAD.

Содержание LX-3

Страница 1: ...Line Splitter jensen transformer equipped Radial Engineering Ltd 1588 Kebet Way Port Coquitlam BC V3C 5M5 Tel 604 942 1001 Fax 604 942 1010 Email info radialeng com user guide...

Страница 2: ......

Страница 3: ...und quality and reliability Before you begin using the LX 3 please take a few minutes to read this short manual and familiarize yourself with the various connections and features the LX 3 offers For a...

Страница 4: ...ground at the XLR output 4 Direct Thru Output Direct output to connect to recording or monitor systems 5 ISO Output 1 2 Transformer isolated outputs eliminates hum buzz caused by ground loops 6 Book E...

Страница 5: ...t compressors or effects units to splitting the output of a console to multiple recording devices Inside the LX 3 the signal is divided three ways between the DIRECT THRU ISOLATED 1 and ISOLATED 2 XLR...

Страница 6: ...source the iNPUT pAD Should you have a particularly hot input signal that you are sending to the LX 3 you can engage a 12dB pad to knock down the signal and prevent distortion This is done using the P...

Страница 7: ...may need to engage the ground lift on this output to disconnect the audio ground and help remove buzz and hum on this output Ground lift switches are also present on the isolated outputs to provide fu...

Страница 8: ...plitter allowing you to mix and match as needed Both J RAK models are built of 14 gauge steel with a baked enamel finish Each direct box can be front or rear mounted allowing the system designer to ha...

Страница 9: ...the signal to balanced audio at the isolated outputs The direct output will mirror the input and it will be unbalanced if the input is unbalanced Do I need power to drive the LX 3 No the LX 3 is comp...

Страница 10: ...Distortion 0 001 1kHz Phase Deviation 0 6 20Hz Common Mode Rejection 105dB 60Hz 70dB 3kHz Input Impedance 712 Output Impedance 112 Transformer Jensen JT 123 FLPCH Input Pad 12dB Ground Lifts Disconnec...

Страница 11: ...r User Guide 9 BLOCK DIAGRAM Specifications are subject to change without notice COMBO JACK BAL IN 12dB INPUT PAD INPUT PAD ON OFF JT 123 FLPCH GROUND LIFT GROUND LIFT ISO OUT GROUND LIFT THRU OUT INT...

Страница 12: ...rmed under this limited and transferable warranty This warranty shall not apply if the product has been damaged due to abuse misuse misapplication accident or as a result of service or modification by...

Отзывы: