MENU
• to enter the menu press
, main menu will appear on display
• use buttons
or
to move the cursor . Use button
to select
• moving the cursor to choose the desired function and
to select it.
Symbol
will appear/disappear next to the desired function to indicate that
it has been selected/deselected.
• After 30 seconds of inactivity the device will exit to main menu.
• when batteries are removed, the date and time will reset after 40 hours
DATA TRANSFER
Bluetooth connection to smartphone or tablet only (iOS or Andorid).
Download RadexRead free app from AppStore or PlayStore.
USB connection to Computer - Windows only.
Download software from www.quartarad.com - Support - RD1212-BT
• Save the measurements on your PC.
• Share on the World Map.
• See data from other users on the World Map.
• Save your data for personal use only.
• Chart your data for easy review and analysis.
FLASHLIGHT
To activate the flashlight, press and hold
for a few seconds.
Radiation: How much is harmful?
Not all radiation is the same, so scientists use the ‘sievert’ to measure the health
risks of radiation.
A one-sievert dose of radiation would cause immediate radiation sickness. But
most radiation doses are much smaller, so you’ll see them measured in mil-
lisieverts or even smaller microsieverts.
1 sievert (Sv) = 1000 millisieverts (mSv)
1 millisievert (mSv) = 1000 microsieverts (uSv)
uSv/h
micro Sieverts per hour.
0.10
This is low, it does not get any lower.
0.21
Pretty normal. Depends on local geology.
0.42
Happens occasionally with no real reason.
Just keep an eye on it.
0.83
ALERT - No need to panic, but try to figure
out what is going on, stay out of the rain
and avoid unnecessary trips.
1.25
Real risk of cancer if exposed for a year.
4.17
Real risk of cancer if exposed for 90 days.
20,000
Annual limit for Nuclear Plant Workers.
100,000
Annual limit for Fukushima workers.
Sievert calculations based on Cesium-137 isotope.
TECHNICAL SPECIFICATION
Range of Indications
µSv/h
0,05 to 999
Energy range of registered:
Gamma radiation
X-radiation
Beta-radiation
MeV
0,1 to 1,25
0,03 to 3,0
0,4 to 3,5
Margin of Error
where Р – dose power in µSv/h
%
± (15+6/Р)
Alarm threshold (increments of 0.05)
µSv/h
0,05 to 1,2
Measurement cycle
sec
10
Detection
continous
Batteries ("AAA")
pieces
2
Uninterrupted operation time*
hours
300
Temperature range (humidity should not exceed
85% at 25
o
C / 77
o
F)
°С
-18 to +45
°F
-0.5 to +113
Device dimensions
mm
97 x 68 x 24
in
3.8 x 2.7 x 1
Weight (without batteries)
kg
0,08
oz
2.8
* At factory settings, natural background conditions, no use of flashlight.
FACTORY SETTINGS
Threshold - 0,30 µSv/h
●
Audible alarm - ON
●
Data collection - OFF
Vibrato signal - OFF
●
Backlighting - OFF
Please be advised that the measurement results obtained with the use of
this device should NOT be relied upon as official and conclusive. No official
government body has approved the use of this device.
WHAT IS INCLUDED
RADEX RD1212-BT
AAA Batteries x2
USB cable
Quarta-Rad, Inc.