RECOMMENDATIONS 

ON 

SURVEYING 

OBJECTS

Search of radioactivity source location

1. Disable the threshold function.
2. Switch  ON  the  audible  alarm  and/or  Vibration  signal 

functions

3. Move  the  device  over  probable  location  of  the 

radioactivity  source.  When  doing  so  pay  attention  not 
only to measurement indications but also to frequency 
of  signals. The  signals’  frequency  will  increase  as  the 
source is approached and respectively decrease as the 
source is moved away from.

Performing  radioactivity  survey  of  living  and 
public buildings

1. Perform  radiation  background  measurements  on  the 

open site near the surveyed building in 5 locations.

2. Perform measurements inside the building.
3. If  the  registered  radiation  inside  a  building  exceeds 

radiation  at  the  open  site  by  more  than  0.2  mSv/h, 
this  may  indicate  presence  of  unfavourable  radiation 
environment.

Device appearance

Device operation

Device operation

Setup

Setup

RADEX RD1212

User Guide

10

OPERATIONAL RESTRICTIONS

‡

Do not subject the device to high temperatures

‡

Avoid prolonged exposure to direct sunlight

‡

Do not attempt to disassemble and repair the device

‡

Avoid impacts to the device

‡

Protect the device from liquids

‡

Do not place the device into microwave oven

‡

Do not carry on examination/survey in the presence of 
operating air ionizers/ozonizers

‡

If  you  do  not  plan  to  use  the  device  for  more  than  a 
month, remove batteries

Содержание QUARTA RD1212

Страница 1: ...User manual Radex Rd1212 more information ...

Страница 2: ...Radiation Detector RADEX RD1212 User Guide ...

Страница 3: ...sures radioactivity stores measurement results in memory data transfer to PC self testing Time and Date functions audible alarm vibration alarm LQWHJUDWHG ÀDVKOLJKW multilingual Eng De Fr Rus Jp RADEX RD1212 User Guide Please note that this device uses statistical probability function to calculate radiation values Even in identical circumstances two identical devices may show varying results The r...

Страница 4: ...exRead software 5 Operation of RadexRead software 5 Settings Threshold 7 Data collection 7 Audible alarm 8 Vibration alarm 8 Backlight 8 Time and Date 9 Language 9 Flashlight 9 Miscellaneous 7HFKQLFDO VSHFL FDWLRQ Recommendations on surveying of objects 10 Operational restrictions 10 Symbols used in this Guide selection indicator function is Selected sequence of actions note Device operation Setup...

Страница 5: ...DEVICE APPEARANCE Device operation Setup Miscellaneous RADEX RD1212 User Guide 1 Location of sensor Location of of Loc Battery compartment lid Flashlight Key Mini USB Display Min Key Key ...

Страница 6: ...tion On Off 4 Backlight 5 Key function 6 Key function 7 Measurement result 8 Key function 9 Date 10 Time 11 Background Radiation value 12 Alarm threshold 13 Battery charge indicator high low battery should be replaced 14 Unit of measurement micro Sievert per hour 15 Blinking indicated detection of a quantum 16 Indicator of the number of measurement cycles 1 cycle 10 cycles and more ...

Страница 7: ...om the Main screen press The Main Menu will be displayed use buttons and to scroll the cursor next to desired function Use button to Select move the cursor to the desired function and Select it by pressing A tick mark will Appear Disappear next to the desired function After 30 seconds of inactivity the device will revert to Main Screen Please remove the batteries if the device is not going to be u...

Страница 8: ...iation was measured earlier you may proceed with measuring current radiation in excess of background 1 Enter menu background 2 Move to on position and press DEVICE OPERATION Measurements Measurement begins when the device is turned On The UVW UHVXOW ZLOO DSSHDU RQ GLVSOD DIWHU VHFRQGV Measurements with Background Function While taking measurements with Background Function two radiation values are ...

Страница 9: ...lect Install RadexRead 3 Follow the prompts of the installation Wizard to install RadexRead application Operation with RadexRead program RadexRead allows you to perform the following functions view measurement results stored in memory save results in TXT and CSV formats delete measurement results from the device memory Connecting the device to PC 1 Turn On the device 2 Connect the device to PC usi...

Страница 10: ... 1 Start RadexRead program 2 Select SAVE a dialog box will open 3 6HOHFW SDWK WR VDYH WKH OH 4 QWHU OHQDPH 5 6HOHFW D OH IRUPDW LQ ZKLFK WKH PHDVXUHPHQW UHVXOWV ZLOO be stored 6 Click SAVE Deleting data from PC memory 1 Start RadexRead program 2 click DELETE Device appearance Setup Miscellaneous RADEX RD1212 User Guide 6 ...

Страница 11: ...DEX RD1212 User Guide 7 SETUP Threshold This function allows to set dose power level value which will trigger an alarm Audible or Vibration Turning ON Alarm function 1 Select menu levels 2 Move to on position and press Turning OFF Alarm function 1 Select menu levels 2 Move to off position and press Setting threshold level to trigger an alarm 1 Select menu levels 2 Move to a numerical value and pre...

Страница 12: ...n allows the vibration signal to respond to registration of a quantum In case a threshold function is turned ON the vibration signal is issued when registered value exceeds the threshold level Switching ON vibration alarm 1 Select menu setup 2 Move to vibra call and press a tick symbol will appear next to vibra call Switching OFF vibration alarm 1 Select menu setup 2 Move to vibra call and press a...

Страница 13: ... 0 30 µSv h Audible alarm on Date collection off Vibration signal off Backlight off Device appearance Device operation Device operation Setup Setup RADEX RD1212 User Guide 9 Time and date Setting TIME 1 Select menu setup time and date 2 Move WR WKH UVW OLQH WLPH DQG SUHVV 3 Use or to set hours and press 4 Use or to set minutes and press Setting DATE 1 Select menu setup time and date 2 Move to the ...

Страница 14: ...ite near the surveyed building in 5 locations 2 Perform measurements inside the building 3 If the registered radiation inside a building exceeds radiation at the open site by more than 0 2 mSv h this may indicate presence of unfavourable radiation environment Device appearance Device operation Device operation Setup Setup RADEX RD1212 User Guide 10 OPERATIONAL RESTRICTIONS Do not subject the devic...

Отзывы: