23
EN
10.1 Test run / modifying the end points
1.
Check the direction of travel of the motor. Switch
the lines for the direction of rotation if required, see
connection diagram
[ 24 ]
on page 19.
2.
Check the configuration and allow the roller shut-
ter to run in both directions, until the end points
switch off the motor.
Modifying the end points
Move the roller shutter back to the centre position
and begin the process again.
ATTENTION!
The tubular motors are designed for transient
operation (approx. 4 mins).
If this period is exceeded, or if the equipment is
switched over frequently, then the motor may heat
up and the thermal protection system will shut it off.
◆
In this case, allow the motor to cool down for
20 minutes.
11. Loading factory settings during the commissioning process
Self-learning mode with a soft stop is active again
after loading the factory settings.
Notes for carrying out the configuration
◆
In order to carry out this configuration, it is neces-
sary to connect the two control lines for up (
▲
) and
down (
▼
) separately to the phase
( L )
.
◆
Verwenden Sie dazu entweder das im Fachhan-
del erhältliche neue Universal-Einstellkabel
(21)
oder das ältere Schnurschaltersetzgerät oder
einen externen Taster mit zwei Schaltkontakten.
◆
The tubular motor may not be in operation.
Factory settings:
End points:
No end points
stored
Self-learning mode with
soft stop:
activated
Proceed as follows:
1.
Connect both directions of travel to the mains supply for approx. 5 seconds until
the tubular motor confirms this by briefly running up and down.
5 sec.
◆
Switch
button 1
to any position and press
button 2
(set button)
when using the universal setting cable
(21)
.
◆
Please press the ON switch and SET button at the same time when using a
cord-switch setting unit.
◆
Please press both buttons at the same time when using an external button.
After that the factory settings are loaded.
2.
Switch off the mains power supply and reconfigure the original connection in accordance with connection diagram
[ 24 ]
on page 19, if you have carried out the setting with the universal setting cable or with a cord-switch setting unit.
Содержание RolloTube CLIS