![RADEMACHER RolloTron Swivel Winder Standard DuoFern... Скачать руководство пользователя страница 90](http://html1.mh-extra.com/html/rademacher/rollotron-swivel-winder-standard-duofern/rollotron-swivel-winder-standard-duofern_translation-of-the-original-operating-and-assembly-manual_3221423090.webp)
90
EN
19. Removing the belt in the event of unit failure
In the event that the RolloTron Swivel Winder Standard
DuoFern unit fails and the motor no longer runs, you can
use the disengaging bracket provided in order to fully
remove the belt from the belt winder unit, without the
need for cutting it.
WARNING!
WARNING!
There is a risk of injury as the roller shutters may slam
shut or fall in an uncontrolled manner.
◆
Secure the roller shutters from falling, for example,
by laying something underneath it.
◆
Hold on to the belt tightly to stop the roller shutters
from slamming shut or falling in an uncontrolled
manner.
◆
Get a second person to help you unlatch the unit.
i
4.
Maintain pressure on the disengaging bracket and pull
the belt out of the RolloTron Swivel Winder Standard
DuoFern as far as possible.
1.
Remove the mains plug from the
socket.
2.
Turn the RolloTron Swivel Winder
Standard DuoFern completely to the
side.
3.
Release the drive with the help of the supplied disen-
gaging bracket. A small amount of resistance must be
overcome when pressing.
5.
Remove the reel compartment cover. Release the belt
from the fastening hook and pull it out completely from
the RolloTron Swivel Winder Standard DuoFern.
6.
Press the assembly locking device on the back part
and pull remove the RolloTron Swivel Winder Standard
DuoFern from the wall bracket by pulling it downwards.
7.
Place the disengaging bracket back into the storage
compartment.
Drive release
Storage bay