7.3  Expert knowledge required by the installer

The electrical connection, installation and commissioning of the 
DuoFern Universal Actuator 9470-1 must only be carried out by 
a qualified electrician in accordance with the instructions in this 
manual.

8.  Connecting the DuoFern Universal Actuator 9470-1

8.1  Safety instructions for the electrical connection

 DANGER!

There is a risk of fatal electric shock when touching electri-
cal components. 

 

All connection and installation work must only be carried 
out in a de-energised state.

 

Disconnect all phases of the mains power lead and secure it 
to prevent any reconnection.

 

Check that the system is de-energised.

Prior to the electrical connection, check that the voltage / frequen-
cy on the type plate corresponds to that of the local mains supply.

i

i

Содержание DuoFern Universal 9470-1

Страница 1: ...VBD 623 3 12 20 Item no 3514 02 61 EN DuoFern Universal Actuator 9470 1 1 channel Instruction manual for the electrical connection and for commissioning Type 9470 1...

Страница 2: ...ou for the trust you have placed in us RADEMACHER products have been developed with the greatest possible convenience in mind Having applied uncompromising quality standards and thorough testing we ar...

Страница 3: ...iption of the functions and parameters 15 6 Technical specifications 17 7 Safety instructions 20 7 1 Intended use 20 7 2 Improper use 21 7 3 Expert knowledge required by the installer 22 8 Connecting...

Страница 4: ...4 EN Contents i 10 Deleting all settings reset 30 11 Dismantling 30 12 Simplified EU declaration of conformity 31 13 Warranty terms and conditions 31...

Страница 5: ...tion manuals of the accessories if available as well as the instructions of the respective con nected appliance This manual is part of the product Please store it in an easily accessible place When pa...

Страница 6: ...angerous situation 2 1 Levels of danger and signal words DANGER This hazard will lead to serious injury or death if not avoided WARNING WARNING This hazard may result in serious injury or death if not...

Страница 7: ...7 EN 2 2 Symbols and depictions used Depiction Description 1 Procedures 2 Itemisation 1 or a Lists i Further useful information Please read the respective manual i...

Страница 8: ...patible products WR ConfigTool RADEMACHERsoftwareforprogrammingtheDuoFernManual Control incl automatic software updates for the DuoFern Manual Control HomePilot The HomePilot is a central controller u...

Страница 9: ...9 EN i 3 Included in delivery Included in delivery a 1 x DuoFern Universal Actuator 9470 1 incl antenna b 1 x instruction manual not illustrated a...

Страница 10: ...2 1 4 Pos Symbol Description 1 Control input 230V 50 Hz on off Connection of an external switch button for manual control on site 2 Relay contact K Connection of an electrical appliance 3 Neutral con...

Страница 11: ...light status display green flashing constantly lit up brief flashing Connection is active Connection or disconnection was successful Control command received red flashing or permanently lit up Disconn...

Страница 12: ...eration on site Installation and electrical connection The DuoFern Universal Actuator 9470 1 is designed for flush mounting The electrical connection is carried out by means of clamping the connecting...

Страница 13: ...e range Factory setting A B C D E F G 1 Manual operation On Off Dim 2 Unit light mode Unit light mode Light mode 3 Manual mode on off on off off 4 Automatic timer on off on off on 5 Random function 6...

Страница 14: ...Standard DuoFernWall Controller Function Value range Factory setting A B C D E F G 12 Connectivity test 13 Connect with radio code 14 Reset via radio 3 stage 15 Single button operation 16 Stairwell f...

Страница 15: ...f On Dawn function On Off Automatic dusk function Off On Random function presence simulation The DuoFern Universal Actuator 9470 1 can process random functionswitchingcommands Ifaswitchingcommandisrec...

Страница 16: ...irway function on off When the stairway function is active the DuoFern Universal Actuator 9470 1 will switch off the controlled device again after the set stairway time An advanced switch off warning...

Страница 17: ...for an external manual switch button on site Input voltage 230 V Ri 200 kW Relay output load contact K Switching voltage 230 V 50 Hz Maximum switching capacity Ohmic load e g bulbs 16 A 3600 W Inducti...

Страница 18: ...ations Improper use can lead to serious injuries or property damage Small contact distance not suitable for disconnecting the device Do not use the DuoFern Universal Actuator 9470 1 to discon nect the...

Страница 19: ...tion Permissible ambient temperature range 20 C to 55 C Dimensions W x H x D 48 7 x 45 7 x 19 8 mm Connecting terminals Spring resistance connecting terminals 0 1 mm2 1 5 mm2 for solid conductors 6 Te...

Страница 20: ...within the permissible load limits see Technical Specifications The DuoFern Universal Actuator 9470 1 is suitable for connect ing the mains voltage and extra low voltage ELV with basic insulation Oper...

Страница 21: ...xtra low voltage SELV Never use the radio system e g DuoFern radio system and its components for the remote control of devices and systems with increased safety relevant requirements or where there is...

Страница 22: ...tuator 9470 1 8 1 Safety instructions for the electrical connection DANGER There is a risk of fatal electric shock when touching electri cal components All connection and installation work must only b...

Страница 23: ...observe the details in the Technical Specifications see page 18 ATTENTION A defective antenna can lead to malfunctions or failure of the DuoFern Universal Actuator 9470 1 The antenna lead must not be...

Страница 24: ...0 1 is intended for flush mounting We recommend installation in a deep 58 mm flush mounted box or in an electronic socket Length of insulation stripped 9 mm All leads must be stripped to 9 mm 8 2 Impo...

Страница 25: ...1 3 Remove the insulation on all leads as specified above and con nect them according to the following connection diagram 4 InserttheDuoFernUniversalActuator9470 1intotheflush mount ed box and lay the...

Страница 26: ...ermany N L PE 230 V 50 Hz N PE L Appliance Control input E Relay contact K Power supply L i External switch button Neutral conduc tor N Required connecting cable and cable cross section for con nectin...

Страница 27: ...K L N L 1 2 N 230 V 50 Hz L Relay contact K 230 V 50 Hz Toggle switch Control input E Relay contact K Appliance Installation with toggle switches We recommend replacing the toggle switch with several...

Страница 28: ...e DuoFern Universal Actuator 9470 1 3 The DuoFern Universal Actuator 9470 1 then transmits either a log on or log off signal Log on log off mode remains active for 120 seconds 4 If the log on log off...

Страница 29: ...to the actuator after installation You will find the radio code on the enclosed label and on the rear side of the DuoFern Universal Actuator 9470 1 i Please note that the use of the radio code is limi...

Страница 30: ...reset can be carried out to reset the DuoFern Universal Actuator 9470 1 to the default factory settings 11 Dismantling DANGER There is a risk of fatal electric shock when touching electri cal componen...

Страница 31: ...24 monthwar ranty for new systems that have been installed in compliance with the installation instructions All construction faults material de fects and manufacturing defects shall be covered by the...

Страница 32: ...by replacement of the affected parts or by supplying a new replacement unit or one to the same value There is no general extension of the original warranty period by delivery of a replacement or by r...

Отзывы: