Pos. Symbol
Description
18)
E2
E1
L N
Control inputs [ E1 (
s
) / E2 (
t
) ]
230 V / 50 Hz
Connection of external push-buttons or
controllers. Parallel connection of several
devices is possible on both inputs.
E1 / E2 and the Troll Basic 5602 must be connected to
the same phase [
L
], see page 25.
19)
E2
E1
L N
Voltage supply [ L / N ] 230 V / 50 Hz
Connection of the supply voltage.
20)
E2
E1
L N
Rotational direction [Down/Up]
Connecting cables to the tubular motor.
5.2 Electrical connections