RADEMACHER 3514 06 62 Скачать руководство пользователя страница 24

24

EN

i

9.1  Logging on and off via radio code

You can control the DuoFern Tubular Motor Actuator 9471-1 direct-
ly using the radio code in order, for example, to be able to connect 
further DuoFern transmitters to the actuator after installation. You 
will find the radio code on the enclosed label and on the rear side 
of the DuoFern Tubular Motor Actuator 9471-1.

i

  Please note that the use of the radio code is limited 

to 120 minutes after switching on the power supply

  A detailed description on activating the radio code 

function can be found in the instruction manual of 
the DuoFern Manual Control and the HomePilot®.

Содержание 3514 06 62

Страница 1: ...VBD 621 5 12 20 Item no 3514 06 62 EN DuoFern Tubular Motor Actuator 9471 1 Instruction manual for the electrical connection and for commissioning Type 9471 1 ...

Страница 2: ...Thank you for the trust you have placed in us RADEMACHER products have been developed with the greatest possible convenience in mind Having applied uncompromising quality standards and thorough testing we are proud to be able to present this innovative product to you It s brought to you by all the highly quali fied personnel here at RADEMACHER ...

Страница 3: ...l specifications 14 7 Safety instructions 16 7 1 Intended use 16 7 2 Improper use 17 7 3 Expert knowledge required by the installer 18 8 Safety instructions for the electrical connection 18 8 1 Important information regarding the electrical connection 19 8 2 Connecting and installing the DuoFern Tubular Motor Actuator 9471 1 21 8 3 Connection diagram 22 9 Logging DuoFern transmitters on off 23 9 1...

Страница 4: ...se also read the instruction manual of the respective connected tubular motor This manual is part of the product Please store it in an easily accessible place When passing the DuoFern Tubular Motor Actuator 9471 1 on to a third party this manual must be passed on as well Damage resulting from non compliance with these instruc tions and safety instructions will void the guarantee We assume no liabi...

Страница 5: ...dangerous situation 2 1 Levels of danger and signal words DANGER This hazard will lead to serious injury or death if not avoided WARNING WARNING This hazard may result in serious injury or death if not avoided CAUTION This hazard may result in minor or moderate injury if not avoided ATTENTION This hazard may lead to property damage i ...

Страница 6: ...6 EN 2 2 Symbols and depictions used Depiction Description 1 Steps to be taken 2 Itemisation 1 or a Lists i Further useful information Please read the respective manual i ...

Страница 7: ...hnology for controlling compatible products WR ConfigTool RADEMACHERsoftwareforprogrammingtheDuoFernManual Control incl automatic software updates for the DuoFern Manual Control HomePilot The HomePilot is a central controller unit for RADEMACHER radio products ...

Страница 8: ...8 EN i 3 Included in delivery Included in delivery a 1 x DuoFern Tubular Motor Actuator 9471 1 incl antenna b 1 x instruction manual not illustrated a ...

Страница 9: ... shutter switch button for manual control on site 2 Rotation direction up down Connecting cables to the tubular motor 3 230V 50 Hz Connection of the supply voltage 4 230V 50 Hz internally bypassed The phase L can be forwarded to the external roller shutter switch and the neutral conductor N can be forwarded to the tubular motor Do not use to forward the mains voltage to the home installation 3 ...

Страница 10: ...ansmitter 6 STATUS Indicator light status display green flashing constantly lit up brief flashing Connection is active Connection or disconnection was successful Control command received red flashing constantly lit up Disconnection is active Connection or disconnection was not successful 7 Disconnect button Logging off from the DuoFern radio net work or a DuoFern transmitter Reset to the default f...

Страница 11: ... functions of DuoFern sensors and DuoFern transmitters such as the HomePilot Manual operation on site An additional external locking roller shutter switch or button can be connected to enable manual operation on site Installation and electrical connection The DuoFernTubular Motor Actuator 9471 1 is designed for flush mounting The electrical connection is carried out by means of clamping the connec...

Страница 12: ... Manual mode on off on off off 4 Automatic timer on off on off on 5 Random function 6 Dawn function 7 Automatic dawn function on off on off off 8 Automatic dusk function 9 Automatic dusk function on off on off off 10 Sun function 11 Automatic sun function on off on off off 12 Sunshine position 0 100 50 13 Wind function 14 Automatic wind function on off on off off 15 Wind rotation direction Up down...

Страница 13: ...tation direction on off off 23 Connectivity test 24 Connect with radio code 25 End point setting for RADEMACHER tubular motors via radio 26 Reset via radio 3 stage 27 Single button operation 28 Jog mode 29 Venetian blind mode on off off 30 Standard slat position 0 100 0 31 Automatic tilt after manual stop direction Down on off on 32 Automatic tilt to sunshine position on off off 33 Automatictiltto...

Страница 14: ...switch button on site Input voltage 230 V 50 Hz Ri 200 kW Rotation direction s t Output voltage 230 V 50 Hz Maximum switching capacity M 2 5 A 550 W Improper use can lead to serious injuries or property damage Small contact distance µ not suitable for disconnecting the device Do not use the DuoFern Tubular Motor Actuator 9471 1 to disconnect the connected appliance ...

Страница 15: ...ax 10 mW Range Indoors approx 30 m Outdoors approx 100 m Depending on the building structure Max number of DuoFern devices 20 General information Permissible ambient temperature range 20 C to 55 C Dimensions W x H x D 48 7 x 45 7 x 19 8 mm Connecting terminals Spring resistance connecting terminals 0 1 mm2 1 5 mm2 ...

Страница 16: ...g and controlling tubular motors for roller shutters and Venetian blinds Operating conditions Only use the DuoFern Tubular Motor Actuator 9471 1 in dry rooms A 230 V 50 Hz power supply together with a site provided disconnecting device fuse must be available at the instal lation location The installation and operation of the radio systems is only permittedforsystemsanddeviceswhereamalfunctioninthe...

Страница 17: ...re there is an accident risk Applications of this kind require additional safety equipment Observe the respec tive statutory regulations for the installation of systems of this kind Using the DuoFern Tubular Motor Actuator 9471 1 for any other purpose than previously mentioned is not permissible There is a risk to life caused through short circuiting and electric shocks if the DuoFernTubular Motor...

Страница 18: ...y instructions for the electrical connection DANGER There is a risk of fatal electric shock when touching electri cal components All connection and installation work must only be carried out in a de energised state Disconnect all phases of the mains power lead and secure it to prevent any reconnection Check that the system is de energised Priortotheelectricalconnection checkthatthevoltage frequen ...

Страница 19: ...r 9471 1 The antenna lead must not be shortened and damaged 8 1 Important information regarding the electrical connection Connection instructions for operating with an external roller shutter switch button on site It is imperative that a locking roller shutter switch button is used in order to avoid increased current consumption and excessive heat build up When using the control input sEt you must...

Страница 20: ... not be installed on a metallic base or near metal objects The DuoFern Tubular Motor Actuator 9471 1 is intended for flush mounting We recommend installation in a deep 58 mm flush mounted box or in an electronic socket Please read the specifications relating to the electri cal connection detailed in the instruction manual for the tubular motor 8 1 Important information regarding the electrical con...

Страница 21: ...down to 9 mm as specified above and connect them according to the following connection diagram 4 Insert the DuoFern Tubular Motor Actuator 9471 1 into the flush mounted box and lay the connecting cables as well as the antenna in the box 5 Finally install the cover of the flush mounted box and switch on the mains power supply again 8 2 Connecting and installing the DuoFern Tubular Motor Actuator 94...

Страница 22: ...hrmotor Aktor 1 M N PE L N L N E Made in Germany External roller shutter button Control input Up Tubular motor Rotation direction Up i The set line must be connected to the neutral conductor N on RADEMACHER electronic tubular motors Control input Down Rotation direction Down Set line ...

Страница 23: ...log off buttonoftheDuoFernTubularMotorActuator9471 1 3 The actuator then transmits either a log on or log off signal Log on log off mode remains active for 120 seconds 4 If the log on log off process is successful the STATUS LED will light up green constantly 5 Log on log off from the next DuoFern transmitter To do so repeat steps 1 to 3 or else terminate the log on log off process Observe the STA...

Страница 24: ...the actuator after installation You will find the radio code on the enclosed label and on the rear side of the DuoFern Tubular Motor Actuator 9471 1 i Please note that the use of the radio code is limited to 120 minutes after switching on the power supply A detailed description on activating the radio code function can be found in the instruction manual of the DuoFern Manual Control and the HomePi...

Страница 25: ... reset can be carried out to reset the DuoFern Tubular Motor Actuator 9471 1 to the default factory settings 11 Dismantling DANGER There is a risk of fatal electric shock when touching electri cal components Disconnect all phases of the mains power lead and secure it to prevent any reconnection Check that the system is de energised 1 Log the DuoFern Tubular Motor Actuator 9471 1 off from the DuoFe...

Страница 26: ...HER Geräte Elektronik GmbH hereby declares that the DuoFern Tubular Motor Actuator 9471 1 complies with the Directive 2014 53 EU Radio Equipment Directive The full text of the declaration of conformity is available at the following website www rademacher de ce ...

Страница 27: ... and modifications by third parties unauthorised persons Use of unsuitable accessories Damage caused by unacceptable excess voltages e g light ning Operational malfunctions caused by radio frequency overlap ping and other such radio interference A prerequisite for the warranty is that the new device must have been purchased from one of our approved specialist retailers Proof of this must be provid...

Страница 28: ...e Service Hotline 01807 933 171 Fax 49 2872 933 253 service rademacher de Subject to technical modifications misprints and errors excepted Illustrations not binding 30 seconds free of charge subsequently 14 cents minute from German fixed line networks and max 42 cents minute from German mobile networks ...

Отзывы: