45
45
EN
1. ... 4.
4.
5.
1. ... 4.
. . .
. . .
▲
Logging on DuoFern end units (for item no. 3232 03 64 / 3248 03 66)
Press the desired device button that you subse-
quently want to use to select the device.
Observe the status LED
Green:
Log-on was successful.
Red:
The button is already fully allocated.
Repeat points 1 to 4 in order to log on the next
device or the next actuator.
The following applies for devices with multiple channels:
◆
If a device has multiple channels (e.g. DuoFern Universal Actua-
tor), you must select a group button for each channel.
◆
For devices with multiple channels, the device automatically
jumps to point 3 until all channels have been processed.
◆
You must press the stop button if you do not want to allocate a
channel or want to skip a channel.
Logging on a device several times
You can also log on a device several times, for example, to
realise single and group control:
◆
RolloTron Standard DuoFern 1
on button 1
◆
RolloTron Standard DuoFern 2
on button 2
◆
RolloTron Standard DuoFern 3
on button 3
◆
RolloTron Standard DuoFern 1/2/3 on button 4
Observe the maximum possible number of devices per
button (see page 59).