background image

VBD 697-2 (06.21)

Item no. 3200 44 64

EN

DuoFern Sun/Wind Sensor

Instruction manual

Type: 9499

Содержание 3200 44 64

Страница 1: ...VBD 697 2 06 21 Item no 3200 44 64 EN DuoFern Sun Wind Sensor Instruction manual Type 9499 ...

Страница 2: ...llation sequence 15 9 Menu overview 16 10 Menu 1 Configuring the sun function 17 11 Menu 2 Configuring the wind function 19 12 Menu 8 Service functions 22 12 1 Menu 8 1 Sun test function 23 12 2 Menu 8 1 Wind test function 25 12 3 Menu 8 2 Rotation direction test change of rotation direction 26 12 4 Menu 8 3 Checking the battery status 27 12 5 Menu 8 0 Viewing the software version 28 13 Menu 9 Log...

Страница 3: ...3 EN Contents i 14 Reset factory settings 36 15 Cleaning and care 37 16 Simplified EU declaration of conformity 38 ...

Страница 4: ...n easily accessi ble place When passing the DuoFern Sun Wind Sensor on to a third party this manual must be passed on as well Damage resulting from non compliance with this manual and the safety instructions will void the warranty We assume no liability for any resulting damage i 2 Hazard symbols The following hazard symbols are used in this manual Danger area dangerous situation Levels of danger ...

Страница 5: ...5 EN 2 1 Symbols and depictions used Depiction Description 1 Procedures 2 Itemisation 1 or a List i Useful information Please read the respective manual i ...

Страница 6: ...e g the awning drive and secure it against being switched on again until the defect has been rectified Improper use leads to an increased risk of injury e g from crush ing Take due care while adjusting the associated system e g awning or roller shutter and keep people away from the moving awning or roller shutter Never use the DuoFern Radio System and its components for the re mote control of devi...

Страница 7: ...erating conditions The DuoFern Sun Wind Sensor must be installed at a minimum height of 2 metres i Radio systems that transmit on the same frequency can cause interference Dangers in the case of improper use UsingtheDuoFernSun WindSensorforanyotherpurposethanpreviously mentioned is not permissible i ...

Страница 8: ... Assembly screws 5 x 30 mm Wall plugs 8 mm Installation and operating manual Check the contents of the packaging to make sure that they are com plete and intact i VBD 697 2 06 21 Item no 3200 44 64 EN DuoFern Sun Wind Sensor Instruction manual Type 9499 ...

Страница 9: ...9 EN 5 General view 1 4 5 1 Wind propeller 2 Sensor housing 3 Light sensor 4 Solar cell 5 Wall bracket 6 7 3 2 6 Display 7 Operating buttons 8 Type plate 8 i ...

Страница 10: ...Then you can execute the following functions and setting Button Function In normal mode In the menu M Open the menu Cancel back OK Confirm the setting next UP Increase the current value DOWN Decrease the current value Stop The control signal affects all of the logged on DuoFern devices i ...

Страница 11: ...Light intensity in klux km h Wind velocity km h Pressing any button switches on the display The current weather data wind velocity and light intensity is displayed alternately The menu items and configurable parameters are displayed in the setting menus i If no entry is made for 2 minutes the display turns off The DuoFern Sun Wind Sensor then switches to standby mode i ...

Страница 12: ...olar cell An integrated battery provides the necessary power to the device for 24 hours if there is no sun Safety function when the battery is discharged If the battery does not have sufficient charge due to there being very little sunlight the awnings or shutters are retracted and can no longer be operated when the wind function is activated As soon as the battery is sufficiently charged again th...

Страница 13: ...nsor 10 km h to 99 km h off General information Battery power reserve 24 hours Permissible ambient temperature 10 C to 60 C Protection type IP44 Dimensions L x W x H 255 x 122 x 75 mm DuoFern radio technology Transmission frequency 434 5 MHz Transmission power max 10 mW Range Indoors up to 20 m Outdoors up to 50 m Maximum number of DuoFern devices 3 i ...

Страница 14: ...ed easily Do not install the DuoFern Sun Wind Sensor in the shade of trees and buildings or also in the lee of the wind The DuoFern Sun Wind Sensor must be installed at a minimum height of 2 metres The wind propeller must point downwards and be as horizontal as possible The light sensor and the solar cell must point upwards Installation examples Wall installation Ceiling installation Roof installa...

Страница 15: ...ill holes and drill the holes with an 8 mm drill bit 8 mm 4 Install the DuoFern Sun Wind Sensor with the wall plugs and screws provided 5 Then align the sensor housing horizontally and secure it with the fulcrum screw The solar cell must point upwards The wind propeller must point downwards 6 Finally push the protective caps onto the wall bracket Align horizontally i ...

Страница 16: ...1 Sun wind test functions 23 8 2 Rotation direction test change of rotation direction 26 8 3 Checking the battery status 27 8 0 Software version 28 9 Logging DuoFern devices on off 29 Logging devices on 30 Logging devices off 32 Clear up 34 Deleting all DuoFern devices 35 9 Menu overview i ...

Страница 17: ...ing actu ators It may be necessary to set a running time on the actuator so as to be able to use the sun function The sunshine position of the logged on actuators is auto matically set to 100 by the sun wind sensor The awning fully extends accordingly in the case of sun or the shutter closes completely The sunshine position can be changed manually Either directly on the device or using a DuoFern c...

Страница 18: ...y pressing any button 2 M Select menu 1 3 OK Open the menu 4 Configure the set limit Setting range 1 to 99 klux 99 klux OFF Sun function off or Pressing and holding the stop button accepts the currently measured brightness as the set limit 5 OK Confirm the setting and return to the menu 6 M Back to the standard display i ...

Страница 19: ...n when the sun set limit is exceeded i If the awning was previously manually extended it remains retracted after the value drops below the wind set limit Automatic movement commands e g from a HomePilot which were received during the wind block are resumed after the value drops below the set limit The block is lifted as soon as the value drops below the set limit for 15 minutes i ...

Страница 20: ...the menu 11 Menu 2 Configuring the wind function 4 Configure the set limit Setting range 10 to 99 km h 99 km h OFF Wind function off 5 OK Confirm the set limit and return to the menu 6 M Back to the standard display 1 If the display is off turn it on by pressing any button i ...

Страница 21: ...light wind 1 6 3 3 5 5 11 9 2 Light wind 3 4 5 4 12 0 19 4 3 Moderate wind 5 5 7 9 19 5 28 4 4 Fresh wind 8 0 10 7 28 5 38 5 5 Very fresh wind 10 8 13 8 38 6 49 7 6 Strong wind 13 9 17 1 49 8 61 5 7 Very strong wind 17 2 20 7 61 6 74 5 8 Storm 20 8 24 4 74 6 87 8 9 Heavy storm 24 5 28 4 87 9 102 2 10 Hurricane like storm 28 5 32 6 102 3 117 3 11 Hurricane 32 6 117 3 12 i ...

Страница 22: ...rotation direction Menu 8 3 Display the battery status Menu 8 0 Software version The test functions are used to check the connection and the settings of the controlled device i The sun and wind test functions operate with reduced set limits for the duration of the test Sun 10 klux Wind 10 km h i The test functions should be used after the initial commis sioning i ...

Страница 23: ... 2 If the display is off turn it on by pressing any button 3 M Open menu 8 and select menu 8 1 4 OK 5 OK Open menu 8 1 6 Light up the light sensor e g with a bright torch If the test set limit is exceeded the sun symbol flashes on the display 7 After 5 sec After 5 seconds all awnings extend and or the shutters close i ...

Страница 24: ... you can find more information on page 29 8 15 seconds As soon as the torch is switched off all awnings retract and or the shutters open after 15 seconds 9 OK or M exit the test mode and return to menu 8 Service functions 12 1 Menu 8 1 Sun test function i ...

Страница 25: ...ckly by hand If the test set limit is exceeded the wind symbol flashes on the display 2 If the display is off turn it on by pressing any button 3 M Open menu 8 and select menu 8 1 4 OK 5 OK Open menu 8 1 7 After 2 sec After 2 seconds all awnings retract and or the shutters open 8 OK or M exit the test mode and return to menu 8 Service functions i ...

Страница 26: ...he number corresponds to the log on sequence 5 OK Select the tubular motor actuator to be tested and confirm with OK 6 Test the rotation direction Extend the awning close the shutter Retract the awning open the shutter Stop command Changing the rotation direction as required 7 Press both buttons simultaneously Note the feedback or confirm the tubular motor or actuator 8 Point 1 to 6 Repeat the rot...

Страница 27: ... the battery status 1 If the display is off turn it on by pressing any button 2 M Open menu 8 and select menu 8 3 3 OK 4 OK Open menu 8 3 The current charge of the battery is shown in 5 OK or M return to menu 8 Service functions i ...

Страница 28: ... software version 1 If the display is off turn it on by pressing any button 2 M Open menu 8 and select menu 8 0 3 OK 4 OK Open menu 8 0 The current software version is displayed example 5 OK or M return to menu 8 Service functions i ...

Страница 29: ...obtained from our website at www rademacher de Conditions of use for the sun function In order for the sun function of the DuoFern Sun Wind Sensor to work the following functions must be configured on some DuoFern devices preferably before logging on Total running time If the device has a connection option for its own sun sensor set the mode to External sun sensor Sunshine position recommendation ...

Страница 30: ... the desired DuoFern device to log on mode 5 Start the log on process on the DuoFern Sun Wind Sensor The log on process remains active for a maximum of 2 minutes 5 1 After successfully logging on the number of logged on DuoFern devices is updated on the display 6 OK or M the log on process is terminated after success fully logging on or by pressing the button Continue see next page i ...

Страница 31: ...matic sun function is activated Sunshine position set to 100 The motor will therefore move several times during the log on process 13 1 Logging on devices Behaviour in the event of a failed log on In the event of an error the message Err appears and the log on process is terminated Error causes The maximum number of logged on DuoFern devices has been reached or an attempt has been made to log on a...

Страница 32: ... to log off mode 5 Start the log off process on the DuoFern Sun Wind Sensor The log off process remains active for a maximum of 2 minutes 5 1 After successfully logging off the number of logged on DuoFern devices is updated on the display 6 OK or M the log off process is terminated after success fully logging off or by pressing the button Continue see next page 13 2 Logging off devices i ...

Страница 33: ...g off devices Behaviour in the event of a failed log off In the event of an error the message Err appears and the log on process is terminated Error causes An attempt was made to log off a device that is not logged on i ...

Страница 34: ...e number of logged on DuoFern devices is dis played 4 4 seconds Start the clear up process To do this press and hold the button for 4 seconds All logged on devices are then retrieved Unavailable devices are logged off 4 1 After successfully logging off the number of logged on DuoFern devices is updated on the display 4 2 As soon as the number stops flashing on the display the clear up process is t...

Страница 35: ... pressing any button 2 M Select menu 9 3 OK Open menu 9 The number of logged on DuoFern devices is dis played 4 4 seconds Press and hold the button for 4 seconds All logged on devices are deleted 4 1 Display after all devices have been deleted 5 OK or M return to the main menu i ...

Страница 36: ...on to turn on the display 2 OK OK OK M M M 4 sec Press and hold all 4 buttons simultaneously Then all data is reset to the factory settings Set limits Sun 60 klux Wind 18 km h Logged on DuoFern devices none 2 1 To confirm this all symbols and segments are shown on the display 3 Release the four buttons again The software version is then briefly displayed The standard display then appears again see...

Страница 37: ...eller will no longer turn smoothly and may result in incorrect measurement results For the safe operation of the DuoFern Sun Wind Sensor it is important that it remains as clean as possible and that the wind propeller can be moved easily Clean the DuoFern Sun Wind Sensor regularly with a mild soapy solution Check the wind propeller regularly to ensure it moves easily Carry out a regular function t...

Страница 38: ...Fern Sun Wind Sensor complies with the Directive 2014 53 EU Radio Equipment Directive The full text of the EU declaration of conformity is available at the following website www rademacher de ce Warranty terms and conditions Information about the warranty conditions of our products can be found on our homepage i ...

Страница 39: ...39 EN i ...

Страница 40: ...RADEMACHER Geräte Elektronik GmbH Buschkamp 7 46414 Rhede Germany Subject to technical modifications misprints and errors Illustrations not binding service en rademacher de Tel 49 2872 933 175 ...